| Brand | HK Electrical |
| Series | HNA |
| Input voltage | 24 VDC±15 % |
| Insulation resistance | ≥100 MΩ |
| Dielectric withstand voltage | 1500V |
| Parameter name | Parameter value |
|---|---|
| Measuring range | (0~1500) μmol/mol |
| Maximum permissible errors | ±5 % (displayed values) |
| Repeatability | ≤3% |
| Response time | <60s |
| Parameter name | Parameter value |
|---|---|
| Measuring range | (0~25) % |
| Maximum permissible errors | ±0.5% (volume ratio) |
| Repeatability | ≤1% |
| Response time | <60s |
| Parameter name | Parameter value |
|---|---|
| Measuring range | (-40~100) ℃ |
| Maximum permissible errors | ±2 ℃ |
| Parameter name | Parameter value |
|---|---|
| Measuring range | (0~99) %RH |
| Maximum permissible errors | ±5 %RH |
| Parameter name | Parameter value |
|---|---|
| Alarm output | To realize alarm function, it needs to be connected to the SPDT electronic relay, and the effective alarm of the transmitter is 1 point. Alarm relay contact capacity: Resistive load: 5 A@250 VAC, 5 A@30 VDC Inductive load: 50 VA |
| Input voltage | 24 VDC±15 % |
| Power | 3 W/channel |
| Insulation resistance | ≥100 MΩ |
| Dielectric withstand voltage | 1500 V |
| Dimensions | 174 mm 110 mm 66 mm (LWH) |
| Weight | 0.6 kg |