• Zinc-Oxide Surge Arrester
Zinc-Oxide Surge Arrester
discuss personally
Model
YH10W
YH5W
Basic info
Brand Switchgear parts
Model NO. Zinc-Oxide Surge Arrester
Discharge current 10kA
Series YH5W YH10W
Product Detail

The metal zinc oxide trap is a high-tech product from the 1990s internationally. It uses zinc oxide resistors with excellent nonlinear volt ampere characteristics, which greatly improves the protection characteristics of lightning arresters under steep slopes, lightning waves, and operating waves compared to traditional silicon carbide lightning arresters. Especially zinc oxide resistors have good steep slope response characteristics, no delay in steep slope voltage, low residual voltage during operation, and no discharge dispersion. Thus, it overcomes the inherent disadvantages of high slope discharge voltage caused by steep slope discharge delay and high operation wave discharge voltage due to large dispersion of operation wave discharge in silicon carbide lightning arresters, greatly improving the protection margin under steep slopes and operation waves. Moreover, in terms of insulation coordination, it can achieve similar protection margins for steep slopes, lightning waves, and operation waves, providing optimal protection for power equipment and improving the reliability of protection. Zinc oxide lightning arrester has the ability to absorb lightning overvoltage, operational overvoltage, and power frequency transient overvoltage simultaneously. The composite jacket metal zinc oxide lightning arrester is a high-tech product from the 1990s internationally. It is molded with integral silicone rubber, which has good sealing performance and excellent explosion-proof performance. Pollution is free from cleaning, and can reduce the occurrence of wet flashes in foggy days. It is resistant to electrical corrosion and aging, small in size and light in weight, and collision resistant, which is convenient for installation and maintenance. It is an upgraded product of porcelain bushing lightning arrester.

Know your supplier
Switchgear parts
VoltEdge Solutions​​ specializes in manufacturing premium ​​MV switchgear accessories​​ for global power distribution systems. Our product range includes circuit breaker modules, disconnector spares, and surge arrestors, engineered for ​​24kV+ substations​​ and renewable energy plants. With ISO-certified production and 24/7 technical support, we ensure ​​reliability, compliance​​ with IEC standards, and rapid global supply.
Main Categories
Electrical fittings/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
Sharing of Transformer Concepts and Terminology
Sharing of Transformer Concepts and Terminology
Sharing of Transformer Concepts and TerminologyThe zero-mode impedance of a load is infinite, and its line-mode impedance is also extremely large, approximately 100 times that of the line-mode impedance of the line.The capacitance to ground of a cable is 25-50 times that of an overhead line.The free oscillation frequency of transient capacitive current: 300-1500Hz for overhead lines and 1500-3000Hz for cables.Performance requirements for an external grounding transformer: Under normal power supp
Edwiin
07/28/2025
What is a traveling wave?
What is a traveling wave?
Traveling Waves on LinesA traveling wave on a line refers to a voltage or current wave propagating along the line; it is also defined as a voltage or current signal traveling along a conductor.Steady-state traveling wave: A traveling wave propagating along the line during the normal operation of a system, generated by the system's power supply.Transient traveling wave: A suddenly occurring traveling wave during system operation, caused by ground faults, short-circuit faults, wire breakages, swit
Leon
07/28/2025
Example of Process Improvement for Enhancing Consistency of Small - Batch High - Temperature Special Transformers
Example of Process Improvement for Enhancing Consistency of Small - Batch High - Temperature Special Transformers
Given the lack of manufacturers for such transformers on the market, we design them in - house. We provide technical specs to partners, specifying materials like high - temp enameled wires.Electrical signals from downhole logging tools, transmitted via these transformers, impact formation - to - surface signal reliability. Thus, improving transformer consistency boosts signal uniformity, enhancing logging tool accuracy and our market competitiveness.Our common signal transformers are EI - type,
Vziman
07/28/2025
Analysis of the Process of Transformer Oil of Specialty Transformers Being Contaminated by Microorganisms and the Treatment Measures
Analysis of the Process of Transformer Oil of Specialty Transformers Being Contaminated by Microorganisms and the Treatment Measures
1 OverviewCases of transformer oil contaminated by microorganisms have been reported both domestically and internationally. Individual transformer manufacturers, user units, and research institutions have conducted specialized studies, but all focused on power transformers. This paper targets specialty transformers for specific applications (e.g., rectifier transformers for graphitization furnaces, submerged arc furnace transformers), exploring the process of microbial contamination of their tra
Rockwell
07/28/2025
How is the contradiction between the small grounding residual current and the neutral point displacement voltage exceeding the standard resolved?
How is the contradiction between the small grounding residual current and the neutral point displacement voltage exceeding the standard resolved?
Contradiction PointsIn automatic tracking arc suppression coils, the adjustment precision is high, the residual current is small, and the operation is close to the resonance point.In an automatic tracking arc suppression coil grounding system, two factors must be considered: Under normal operating conditions, the long-term voltage displacement of the neutral point should not exceed 15% of the system's nominal phase voltage; In the case of a ground fault, the grounding residual current should be
Edwiin
07/28/2025
Power Supply Design of the Group Testing Device for Special Transformers in Electrified Railways
Power Supply Design of the Group Testing Device for Special Transformers in Electrified Railways
1 Hardware Design of Tester Power SupplyThis device uses a standard small - signal generating device to generate small - current signals with the required frequency and phase angle. Then, through the amplifying circuit and phase - modulating circuit, the working power supply is generated.1.1 Power Frequency Sine Wave Small - Current Signal Generating DeviceThe sine wave generating circuit is mainly composed of the waveform generating chip MAX038 produced by MAXIM Corporation of the United States
Ron
07/28/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!