| Chapa | Switchgear parts |
| Namba ya Modeli | Mwendo wa ujenzi wa nguvu wa ukuaji wa muda (aibu ya rack) uPs |
| voltage ya chukua | 110-127VAC |
| Ingizo la umeme | 110-127VAC |
| uwezo | 6kVA |
| Siri | HBG |
Mfumo wa HBG unajumuisha busara ya teknolojia ya muda mpya. Mfumo mzima unatumia teknolojia ya kudhibiti namba za DSP na teknolojia ya udhibiti wa kiwango cha juu sana. Inafanikiwa kutengeneza ukuta ndogo, mvua chache, ufanisi mkubwa na ubadilishaji bila kutumia uhakika na teknolojia ya tofauti ya sine ili kuhakikisha kuwa vyombo vya mtumiaji viwe vyanzuri kwa aina zote za vyombo. Tumiko la msingi AC-DC linatumika kutathmini umeme na upeo wa hewa kamili. Kwa kutumia modulai wa upimaji wa umbalao wa kiwango cha juu, umbo wa umeme wa kuongeza unawezekana kukabiliana na umbo wa umeme wa kupunguza kutokuwa na mizizi ya umeme kukamilisha umwagiliaji wa umeme wa juu zaidi ya 95%. Katika mazingira ya kawaida, umeme wa hewa kamili hutumika kwa kutumia mfumo wa AC-DC kutambua umeme wa DCBUS, ambayo baada ya hivyo huchanganuliwa kwa umeme wa 220V AC kwa kutumia inverter. Vitamaduni vyote huwa vitumia umeme wa sine safi ambao tayari umefanuliwa na umefutwa mizizi yake. IGBT yenye ubora unaotumiwa kama kitu cha kubadilisha nguvu. Ingawa na tabia ya kubadilisha kwa kiwango cha juu ya IGBT, kiwango cha inverter ya UPS inaweza kufikia 40KH2, inapokusanya ufanisi wa inverter na ufanisi wa jumla wa UPS. Uongofu wa kiwango cha inverter pia unapunguza sauti ya inverter. Kwa hiyo, kunipa UPS ya mfululizo wa kiwango cha juu ya HBG moja kwa moja katika chumba cha kompyuta hatutazama kufanya kazi yako. UPS ya mfululizo wa kiwango cha juu ya HBG inahusika na seva ya mtandao kupitia programu ya kudhibiti umeme ya menara ya awali ya RS232, inatoa hali ya umeme wakati wowote. Pia inafanikiwa kutatua ufanisi kama kubadilisha mapema, kuhifadhi kwa kiotomatiki, kuanza/kufunga umeme kwa kiotomatiki na kurekodi hali ya umeme, kufanyika majukumu ya kujitunza kwa kiotomatiki, kuzingatia ushauri wa kufunga kwa kiotomatiki, kuhakikisha usalama wa data ya mfumo wa mtandao hata katika maeneo ya mtandao ambayo hayana watu.
Maeneo ya matumizi
Inatumika kwa ukuaji katika maeneo ya data muhimu kama vile mikoa ya kudhibiti mtandao na mikoa ya kompyuta, benki na hisa, kodi, mawasiliano, posta, taarifa, usalama, nyanja, umeme, afya, udhibiti wa ujenzi, na sekuruti ya taifa.
Viwango vya teknolojia
| Model | HBG - 1KR (S) | HBG - 2KR (S) | HBG - 3KR (S) | HBG - 6KR(S) | HBG - 10KR(S) |
|---|---|---|---|---|---|
| Phase | Single Phase Input and Output | Single Phase Input and Output | Single Phase Input and Output | Single Phase Input and Output | Single Phase Input and Output |
| Capacity | 1000 VA / 800 W | 2000 VA / 1600 W | 3000 VA / 2400 W | 6000 VA / 4800 W | 10000 VA / 8000 W |
| Input | |||||
| Input Voltage | 100/110/115/120/127VAC or 200/208/220/230/240VAC | 100/110/115/120/127VAC or 200/208/220/230/240VAC | 100/110/115/120/127VAC or 200/208/220/230/240VAC | 100/110/115/120/127VAC or 200/208/220/230/240VAC | 208/220/230/240VAC |
| Voltage Range | 55+45 VAC or 110~200VAC at 50% load; 85+40VAC or 160~280 VAC at 100% load | 55+45 VAC or 110~200VAC at 50% load; 85+40VAC or 160~280 VAC at 100% load | 55+45 VAC or 110~200VAC at 50% load; 85+40VAC or 160~280 VAC at 100% load | 55+45 VAC or 110~200VAC at 50% load; 85+40VAC or 160~280 VAC at 100% load | 110-300VAC ±3% at 50% load; 176-300 VAC ±3% at 100% load |
| Frequency Range | 40Hz ~ 70 Hz | 40Hz ~ 70 Hz | 40Hz ~ 70 Hz | 40Hz ~ 70 Hz | 46Hz ~ 54 Hz or 56Hz ~ 64 Hz |
| Power Factor | ≥ 0.99@100% load | ≥ 0.99@100% load | ≥ 0.99@100% load | ≥ 0.99@100% load | ≥ 0.99@100% load |
| Output | |||||
| Output Voltage | 100/110/115/120/127VAC or 200/208/220/230/240VAC | 100/110/115/120/127VAC or 200/208/220/230/240VAC | 100/110/115/120/127VAC or 200/208/220/230/240VAC | 100/110/115/120/127VAC or 200/208/220/230/240VAC | 208/220/230/240VAC |
| Voltage Regulation (Battery Mode) | ±1% | ±1% | ±1% | ±1% | ±1% |
| Frequency Range (Synchronous Correction Range) | 47 ~ 53 Hz or 57 ~ 63 Hz | 47 ~ 53 Hz or 57 ~ 63 Hz | 47 ~ 53 Hz or 57 ~ 63 Hz | 47 ~ 53 Hz or 57 ~ 63 Hz | 46Hz ~ 54 Hz or 56Hz ~ 64 Hz |
| Frequency Accuracy (Battery Mode) | 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz | 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz | 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz | 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
| Crest Factor | 3:1 | 3:1 | 3:1 | 3:1 | 3:1 |
| Harmonic Distortion | ≤ 3% THD (Linear Load); ≤5% THD (Non-linear Load) | ≤ 3% THD (Linear Load); ≤5% THD (Non-linear Load) | ≤ 3% THD (Linear Load); ≤5% THD (Non-linear Load) | ≤ 3% THD (Linear Load); ≤5% THD (Non-linear Load) | ≤ 3% THD (Linear Load); ≤5% THD (Non-linear Load) |
| Conversion Time | |||||
| AC to DC | None | None | None | None | 0 ms |
| Inverter to Bypass | 4 ms (Standard Conditions) | 4 ms (Standard Conditions) | 4 ms (Standard Conditions) | 4 ms (Standard Conditions) | 0 ms |
| Waveform (Battery Mode) | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave | Pure Sine Wave |
| Efficiency | |||||
| Mains Mode | 88% | 89% | 90% | 92% | 93% |
| Battery Mode | 83% | 87% | 88% | 90% | 91% |
| Battery | |||||
| Standard Unit | |||||
| Battery Model | 12V / 9AH | 12V / 9AH | 12V / 9AH | 12V / 9AH | 12V / 9AH |
| Quantity (Cells) | 2 | 4 | 6 | 16 | 20 |
| Standard Charging Time | - | 4 hours to 90% | - | 9 hours to 90% | - |
| Maximum Charging Current | - | 1.0A (Max) | - | Preset:1.0A, Max:2.0A | - |
| Charging Voltage | 27.4VDC ±1% | 54.7VDC ±1% | 82.1VDC ±1% | 218.4VDC ±1%
|
- |
| Long-term Unit | |||||
| Battery Model | - | - | Depends on Power Supply Time | Depends on Power Supply Time | - |
| Quantity (Cells) | 2
|
4 | 6
|
16-20 Grain (adjustable) | - |
| Maximum Charging Current | - | 1.0A,2.0A,4.0A,6.0A | - | 1.0A, 2.0A, 4.0A, 6.0A (adjustable, 6A only applicable to 16 batteries) | - |
| Charging Voltage | 27.4VDC ±1%
|
54.7VDC ±1% | 82.1VDC ±1%
|
109.4VDC±1%
|
- |
| Appearance | |||||
| LCD or LED Display | Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Fault Indication | Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Fault Indication | Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Fault Indication | Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Fault Indication | Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Fault Indication |
| Alarm | |||||
| Battery Mode | Beeps every 4 seconds | Beeps every 4 seconds | Beeps every 4 seconds | Beeps every 4 seconds | Beeps every 4 seconds |
| Low Battery | Beeps every 1 second | Beeps every 1 second | Beeps every 1 second | Beeps every 1 second | Beeps every 1 second |
| Overload | Beeps every 1 second | Beeps every 1 second | Beeps every 1 second | Beeps every 1 second | Beeps every 1 second |
| Error | Continuous Beep | Continuous Beep | Continuous Beep | Continuous Beep | Continuous Beep |
| External Dimensions | |||||
| Standard Unit | |||||
| Dimensions (W×D×H)mm | 310 X 438 X 88 | 410 X 438 X 88 | 630 X 438 X 88 | host:530 X 438 X 88【2U】
|
host:580 X 438 X 133【3U】
|
| Net Weight (kg) | 9.9 | 16.9 | 25.6 | host:135
|
host:18
|
| Long-term Unit | |||||
| Dimensions (W×D×H)mm | 310 X 438 X 88 | 410 X 438 X 88 | - | - | - |
| Net Weight (kg) | 5.5 | 8.1 | 8.5 | - | - |
| Operating Environment | |||||
| Temperature and Humidity | Relative Humidity 20-95% and Temperature 0-40°C (No Condensation) | Relative Humidity 20-95% and Temperature 0-40°C (No Condensation) | Relative Humidity 20-95% and Temperature 0-40°C (No Condensation) | Relative Humidity 0-95% and Temperature 0-40°C (No Condensation) | Relative Humidity 0-95% and Temperature 0-40°C (No Condensation) |
| Noise | Less than 50dB@ 1m | Less than 50dB@ 1m | Less than 50dB@ 1m | Less than 55dB @ 1m | Less than 58dB @ 1m |
| Control Management | |||||
| Smart RS-232 / USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC |
| Optional SNMP | Power Management Supports SNMP Management and Network Management | Power Management Supports SNMP Management and Network Management | Power Management Supports SNMP Management and Network Management | Power Management Supports SNMP Management and Network Management | Power Management Supports SNMP Management and Network Management |
*Wakati UPS imewekwa kwenye mfumo wa nguvu na mzunguko wa wastani, nguvu ya tofauti itapungua kwa asilimia 40. Wakati nguvu ya tofauti ya UPS imewekwa kuwa 208VAC, nguvu ya tofauti itapungua kwa asilimia 10.
**Wakati idadi ya batilie za ndani inabadilishwa kuwa 16-19, mashine itapunguza nguvu ya tofauti kutegemea na formula ifuatayo: P-PrtiX (N/20x100%).
***Ikiwa mashine yameinstalika juu zaidi ya mita 1000, nguvu ya tofauti itapungua kwa asilimia 1 kwa kila mita 100 zinazozidi. Ikiwa kutokana na mabadiliko yoyote katika viwango vya bidhaa za sasa, haitakuwa na taarifa kingine.