HECS Series Generator Circuit-breakers

  • HECS Series Generator Circuit-breakers

Key attributes

Brand ROCKWILL
Model NO. HECS Series Generator Circuit-breakers
Rated voltage 25.3kV
Rated normal current 14.5kA
Rated frequency 50/60Hz
Rated short-time withstand current 100kA
Series HECS Series

Product descriptions from the supplier

Description

Overview

The generator circuit-breaker systems are three-phase systems with a SF6 circuit-breaker and a discon-nector in single-phase enclosures, supplied fully assembled on a common frame, with operating mechanisms and control equipment. In addition to the circuit-breaker and disconnector, the generator circuit-breaker systems are available with earthing switch, starting switch, short-circuiting connection, current and voltage transformers, surge capacitor and surge arrester. The single line diagram of a generator circuit-breaker system type HECS is depicted in figure.

Market pioneer

The wide range of ratings with short-circuit currents from 80 to 130 kA makes HECS the most used GCB in the world suitable for power plants with a unit power of up to 800 MW. With small and standardized dimensions HECS is easy to install and highly suitable for replacements and retrofits in existing power plants. HECS has very low lifecycle cost with up to 20,000 close-open (CO) no-load operations or 20 years between main overhauls.

World leader with state-of-art technology

HECS products are type tested according to IEEE C37.013 and in certain aspects even exceed the minimum requirements of IEC/ IEEE 62271-37-013, including switching of fault currents with full phase opposition (180°; out-of-phase). It is also type tested to interrupt generator-source short-circuit current exhibiting delayed current zeros with up to 130% degree of asymmetry.

Digitally integrated with GMS600

HECS is fully integrated with GCB digital monitoring system, GMS600. The GMS600 can perform many functions: data logging, disturbance recording, drive supervi-sion, temperature and SF6 density monitoring. In addition, HECS supports integration of GMS600-A, a breakthrough solution which measures online the contact overlapping time and gives indication of the ablation without the need to go out of operation. Data logged through GMS600 can be connected via the clouds to Digital Enterprise Connect platform.

Compact design

HECS products are fully assembled and factory tested to bring substantial cost and time savings in installation and commissioning at site. Its compact design fits into standard containers for easy transportation, handling and storage.

Technology parameters

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • 300MW+ Unit Generator Circuit Breaker Automatic Tripping: Causes, Phenomena & Handling Measures
    Units with a capacity of 300MW and above are usually connected in a generator-transformer unit configuration and connected to the power system through the circuit breaker on the high-voltage side of the transformer. During the normal operation of the unit, the circuit breaker may trip automatically due to various reasons. Operators must make correct judgments and take timely measures to ensure the safe operation of the unit.1. Causes of Automatic Circuit Breaker Tripping Tripping due to relay pr
    11/27/2025
  • Chinese GCB makers developed complete sets for 1GW unit applications.
    Recently, a Chinese generator circuit breaker manufacturer has successfully developed generator circuit breakers for 1,000MW hydropower and thermal power units, which have passed the group's appraisal and acceptance. Their comprehensive performance has reached the international leading level, filling the domestic gap. This is another major breakthrough following the group's mastery of the technology for large-capacity generator circuit breaker complete sets for 400MW, 600MW, and 800MW units, mar
    11/26/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.