| Marca | Switchgear parts |
| Numerus Modeli | GYAR9 Wifi Smart Auto Recloser Self-recovery PV Special Reclosing Actuator |
| Votum nominatum | AC220V |
| Frequenta nominata | 50/60Hz |
| Series | GYAR9 |
GYAR9 Smart Auto Recloser compatibilis cum interruptoribus circuiti Schneider Electric A9 series air opening IC65N. Intelligentiter upgradet interruptorem (sine affectu ipsius interruptoris). Remotus controlari potest per MODBUS 485 ad clausuram et aperitur automaticam, habet functiones protectionis contra supercargas et curtes circuiti, atque functiones parametrizatas et configurabiles, quae ab MCU iudicari possunt, ad functionem aperiendi interruptorem quando cessat electricitas et claudendi automatico quando restituitur electricitas. Hoc nunc late utitur in distributivis AC photovoltaicis, sicut et in locis difficilibus ad accessum, ubi personale maintenance non potest tempestive esse, sine praesidio locis, et ubi continuitas supply electricitatis est magna.
Standard:EN 50155,GB/T 24338.4-2018,EN 45545-2,IEC 61373
Control Signal:MODBUS-RS485 Wet node 230V high level/pulse signal (optional)
Over&Under Voltage Function:160-270V±5V (Optional)
Effective Control Signal Duration:>400ms
Closing Action Time:<1s
Opening Action Time:<0.5s
Control Circuit Cable Length:≤1500m
Note:At present, there are only reclosing, switch control, and RS485 functions. The Wi-Fi function will be developed later.
Visual voltage display:Visualem ostensionem tensionis facit ut personale maintenance facilius iudicet circuitum in maintenance.
LOCK Padlock Device:Equipatum est cum LOCK padlock device ad mechanismum protectionis duplicem et praebere protectionem addicionalem pro maintenance circuiti.
MODBUS 485:Supportat functionem communicationis remotae per MODBUS 485 ad remota intelligere status operativus dispositivi.
Local Operation Fault Storage:Supportat local operation fault storage, et quando functio communicationis remota restituitur, data dispositivi legi possunt.
Remote Automatic Mode:Modus automaticus remotus potest operari secure et efficaciter basatus in self-test MCU.
| Model | Rated Voltage | Functions | Optional Items |
| GYAR9-AC-G | AC 220V | Auto Reclosing+Dry Contact Control | Digital Display |
| GYAR9-AC-S | AC 220V | Auto Reclosing+Wet Contact Control | Digital Display |
| GYAR9-AC-RS | AC 220V | Auto Reclosing+RS485 Control | Digital Display Timing |
| GYAR9-AC-UV | AC 220V | Self-recovering over&under voltage protection | Digital Display |
| GYAR9-AC-PV | AC 220V | Photovoltaic/power-off open/power-up close | Digital Display |
| GYAR9-DC-RS | DC 48V | Auto Reclosing+RS485 Control | Digital Display Timing |
Remarks: GYAR9 Smart Auto Recloser can be adapted to Acti9 iC65 miniature circuit breaker, and other manufacturers’ circuit breakers with C65 structure can also be customized and adapted.The length of the operating handle can be purchased according to user needs, and can be configured with 1P-4P circuit breakers.
There may be a risk of electric shock, explosion or arc burns
Be sure to cut off all power supplies before maintaining the equipment.
Use an electroscope with an appropriate voltage rating to confirm that all conductors are uncharged.
Failure to follow the above instructions will result in personal injury or death.
| Standard | EN 50155,GB/T 24338.4-2018,EN 45545-2,IEC 61373 |
| Adaption | Acti9 Series 1P-4 |
| Electrical Characteristics | |
| Operating Voltage | 230V AC (70%~125%) 24-48V DC (optional) |
| Control signal | MODBUS-RS485 Wet node 230V high level/pulse signal (optional) |
| Over&under voltage function | 160-270V±5V (Optional) |
| Timing function | Available (optional) |
| Digital display | 3-digit voltage,switching times,fault status |
| Effective control signal duration | >400ms |
| Closing action time | <1s |
| Opening action time | <0.5s |
| Control circuit cable length | ≤1500m |
| Current-carrying capacity of auxiliary contacts(terminals 8-9-10) | 1CO,minimum operating current 3mA(24VDC)(resistive)(optional) |
| Current-carrying capacity of signaling contacts(terminals 5-6-7) | Maximum operating current 2A(30V DC),0.5A(125V AC)(optional) |
| Power consumption | ≤1.5VA(Static);≤25VA(dynamic) |
| Rated insulation voltage | 400V |
| Rated impulse withstand voltage uimp | |
| (between S2C-RM DC and MCB) | 4kV(4.9kV at sea level) |
| Self-locking protection | Within 10s of 3CO/20s of 4CO/30s of 6CO,the product will self-lock and recover automatically after 40s. |
| Electrical life | 10000 times,3 times/minute |
| Mechanical Characteristics | |
| Indicator Light | Green,Normal status |
| Red,MCB overcurrent fault | |
| Auto/Manual switching | Auto Remote control of opening&closing available |
| Manual Remote control of opening&closing disabled | |
| Mechanical life | 10000 |
| Protection class | Ip20 |
| Hazard class according to EN 45545-2 | EN 45545-2 R26/HL3 |
| Shock and vibration resistance According to IEC 61373 | category 1-class A/B-body mounted |
| Resistance to heat and humidity IEC/EN 60068-2-30 | 28 cycles(55℃/90-96%,25℃/95-100%) |
| Ambient Temperature | -25..+70℃ |
| Storage Temperature | -40…+70℃ |
| Installation and Wiring | |
| Power and control signal terminal wiring capacity | 28-12AWG 2.5mm² |
| Auxiliary signal terminal wiring capacity | 28-14AWG 1.5mm² |
| DIN rail mounting | DIN rail EN 60715(35mm) |
| Mounting position | Mounting on DIN rail Any position |