Key attributes

Brand MV Switchgear Accessories
Model NO. GRD9L-R+GYL9 2P RCCB + Auto Recloser
Rated voltage AC220V
Rated frequency 50/60Hz
Series GRD9L-R+GYL9 2P

Product descriptions from the supplier

Description

GRD9L-R+GYL9 2P RCCB + Auto Recloser can be widely used in power grid terminal lines, such as meter boxes, new energy circuit management, PV solar control box, smart electricity, smart home, new energy vehicle charging pile, and so on.

It can be matched with a circuit breaker/leakage protection switch and automatically reclose when MCB / RCCB trips unexpectedly, no need for manual closing, reduce the cost of manual maintenance, and eliminate faults in time to improve efficiency.

built-in 3 reclosing times, continuous closing failure within 15 minutes can send an alarm through auxiliary contact.

With manual / automatic selector switch.

With mechanical/electronic double locking function.

The shaft transmission mode is more stable and reliable.

Can match other accessories.

Work status is indicated by LED.

1-MODULE.

with RS485 interface Control

Technical parameters GRD9L-R
Control mode Auto Reclosing
Supply terminals A1-A2
Voltage range DC 12V
Power input DC max.1W(standby)  max.20W(action)
Voltage range AC220V(50-60Hz)
Supply voltage tolerance -10%;+10%
Power input  AC max.1VA(standby)max.20VA(action)
Supply voltage tolerance -10%;+10%
Supply indication red LED
Action time ≤1s
Auto reclosing times 3
Auto reclosing interval time 10s-60s-300s
Reset the closing times  No trip or manual reset within 15 minutes after the successful closing
Mechanical life 10000
Electrical life(AC1) 4000
operating temperature  -20℃ to +55℃ (-4℉ to 131℉)
Storage temperature  -35℃ to +75℃ (-22℉ to 158℉)
Mounting/DIN rail Din rail EN/IEC60715
Protection degree  IP20
operating position any
overvoltage category
Pollution degree 2
Max.cable size(mm) solid wire max.1×2.5or2×1.5/with sleeve max.1×2.5(AWG12)
Dimensions 82×18×78mm
Weight 80g
combination with accessories
Auxillary contact Yes
Alarm contact Yes
Shunt release Yes Yes
Under-voltage release Yes
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/Tester/Production equipment/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Rockwill Passes Single-Phase Ground Fault Test for Smart Feeder Terminal
    Rockwill Electric Co., Ltd. has successfully passed the real-scenario single-phase-to-ground fault test conducted by the Wenzhou of China Electric Power Research Institute for its DA-F200-302 hood-type feeder terminal and integrated primary-secondary pole-mounted circuit breakers—ZW20-12/T630-20 and ZW68-12/T630-20—receiving an official qualified test report. This achievement marks Rockwill Electric as a leader in single-phase ground fault detection technology within distribution networks.The DA
    12/25/2025
  • Case Studies of Installation and Manufacturing Defects in 110kV HV Circuit Breaker Porcelain Insulators
    1. SF6 gas leakage occurred in the ABB LTB 72 D1 72.5 kV circuit breaker.Inspection revealed gas leakage at the fixed contact and cover plate area. This was caused by improper or careless assembly, where the dual O-rings slipped and were misplaced, resulting in gas leakage over time.2. Manufacturing Defects on the Outer Surface of 110kV Circuit Breaker Porcelain InsulatorsAlthough high-voltage circuit breakers typically have their porcelain insulators protected with covering materials during tra
    12/16/2025
  • Overview of Defect Diagnosis Methods for High-Voltage AC Circuit Breakers
    1. What are the characteristic parameters of the coil current waveform in high-voltage circuit breaker operating mechanisms? How to extract these characteristic parameters from the original trip coil current signal?Answer: The characteristic parameters of the coil current waveform in high-voltage circuit breaker operating mechanisms may include the following: Steady-state peak current: The maximum steady-state current value in the electromagnet coil waveform, representing the position where the
    12/16/2025
  • A Brief Discussion on the Issues of Converting Reclosers into Outdoor Vacuum Circuit Breakers for Use
    The rural power grid transformation plays an important role in reducing rural electricity tariffs and accelerating rural economic development. Recently, the author participated in the design of several small-scale rural power grid transformation projects or conventional substations. In rural power grid substations, conventional 10kV systems mostly adopt 10kV outdoor auto circuit vacuum reclosers.To save investment, we adopted a scheme in the transformation that removes the control unit of the 10
    12/12/2025
  • A Brief Analysis of Automatic Circuit Recloser in Distribution Feeder Automation
    An Automatic Circuit Recloser is a high-voltage switching device with built-in control (it inherently possesses fault current detection, operation sequence control, and execution functions without requiring additional relay protection or operating devices) and protective capabilities. It can automatically detect the current and voltage in its circuit, automatically interrupt fault currents according to inverse-time protection characteristics during faults, and perform multiple reclosures accordi
    12/12/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.