| Muhimmiya | Switchgear parts |
| Model NO. | GR8 Intermediate Relay AC/DC 12V,24V,48V,110V,AC230V |
| Dịka ọkwa (AC/DC) | 12V、24V、48V、110V |
| Siri | GR8 |
Siriya GR8 na modular intermediate relay ya fara da ingantaccen cutar tashar, yana da muhimmanci a cikin ingantattun automata, kontrolar kuli, da kuma sayoyin aiki. Ingantaccensu ta shirya tushen baka mai kyau, wanda yake iya zama da amfani a cikin hanyar karfin siffarwa da kula da alamar kula, kuma yana ba da amsa ga dukkan abubuwan da za su iya bukatar.
Abubuwan da ke IEE-Business GR8 na modular intermediate relay:
1. Amfani da fadin voltaji
Yana da amfani da AC/DC 12V, 24V, 48V, 110V, da kuma AC 220V na voltaji, don in ba da amsa ga dukkan abubuwan da za su iya bukatar.
2. Kyakkyawar kontrolar fase uku
Model GR8-316 an gina ne musamman don kyakkyawar fase uku, kuma yana da amfani a cikin kontrolar kula da fase uku.
3. Tabbacin aiki
An gina fitaccen LED na haske mai kyau, don in tabbata aiki na on/off na relay, tare da aiki mai kyau ga wasuwar aiki.
4. Cutar tashar
Karamin girma 18mm mai tsakiyar, da amfani da instalaciya na rail na DIN da take 35mm, yana taimakawa da rike aiki na control cabinet.
5. Karfi na tushen baka
Ingantaccensu ta shirya tushen baka mai kyau, wanda yake iya zama da amfani a cikin hanyar karfin siffarwa da kula da alamar kula, kuma yana ba da amsa ga dukkan abubuwan da za su iya bukatar.
Abubuwan da ke IEE-Business GR8 na modular intermediate relay:
1. Karfin siffarwa da kula
Yana amfani don in zama da amfani da siffarwa da kula, kuma in kula da kula mai girma da adalci.
2. Hanyar karfin siffarwa da kula
Daga bambanta masu tushen baka, siffarwa da kula mai babban kan ya iya amfani don in kula da wasu abubuwan da za su iya bukatar.
3. Sistemai na automata industri
PLC output signal expansion
Isolation and conversion of instrument and meter signals
Construction of equipment interlocking control circuit
4. Kyakkyawar kontrolar kuli
Signal transfer in distribution cabinet
Expansion of protection device interface
Three phase motor control (GR8-316 model)
5. Building electrical field
Multi channel signal management relay for building automation systems, lighting control circuits, and ventilation equipment

| Model | GR8-116 | GR8-208 | GR8-308 | GR8-316 |
| Supply terminals | A1-A2 | A1-A2 | ||
| Voltage range | AC/DC 12V、24V、48V、110V | AC/DC 12V、24V | ||
| Burden | AC.max 12VA/DC.max1.9W | |||
| Supply terminals | A1-A2-A3 | A1-A2 | ||
| Voltage range | AC230V(A1-A2),AC/DC24V(A1-A3) | AC230V | ||
| Burden | AC.max 12VA/DC.max1.9W | AC.max 6VA | ||
| Supply voltage tolerance | -15%;+10% | |||
| Max.chargeover time | 40ms | |||
| Output | ||||
| Number of contact | 1×SPDT | 2×SPDT | 3×SPDT | 3×SPDT |
| Current rating | 16A/AC1 | 8A/AC1 | 16A/AC1 | |
| Switching voltage | 250VAC/24VDC | |||
| Min.breaking capacity DC | 500mW | |||
| Output indication | Red LED | |||
| Mechanical life | 1*107 | |||
| Electrical life(AC1) | 1*105 | |||
| Reset time | max.200ms | |||
| Operating temperature | -20℃ to+55℃(-4℉to131℉) | |||
| Storage temperature | -35℃ to+75℃(-22℉to158℉) | |||
| Mounting/DIN rail | Din rail EN/IEC 60715 | |||
| Protection degree | IP40 for front panel/IP20 terminals | |||
| Operating position | any | |||
| Overvoltage cathegory | III. | |||
| Pollution degree | 2 | |||
| Max.cable size(mm²) | solid wire max.1×2.5or 2×1.5/withsleeve max.1×2.5(AWG12) | |||
| Dimension | 90×18×64mm | |||
| Weight | 44g/54g | 50g/60g | 72g/82g | 86g/96 |