• Flameproof Dry-Type Mining Substation Transformer
  • Flameproof Dry-Type Mining Substation Transformer
Flameproof Dry-Type Mining Substation Transformer
discuss personally
Model
KBSGZY2-T-100/10
Basic info
Brand ROCKWILL
Model NO. Flameproof Dry-Type Mining Substation Transformer
Rated voltage 100kV
Rated frequency 50/60Hz
Series KBSGZY
Product Detail

Product Introduction

The KBSGZY series flameproof dry-type mining transformers adopt a fully corrugated cylindrical flameproof enclosure and select high-quality materials to enhance operational reliability. They require no maintenance during normal operation. These transformers are suitable not only for underground mines, tunnels and other environments with methane mixtures and coal dust where explosion hazards exist, but also for environments with gases and vapors that are not corrosive enough to metals or destructive to insulation.

Operating Principle

 The variable frequency transformer section is designed to obtain two sets of three-phase power supplies with a phase difference of 30 degrees through low-voltage dual-splitting. An electrostatic screen is placed between the high and low-voltage sections, and the insulation level of the low-voltage coils is raised to a voltage rating of 10KV to meet the higher common-mode voltage generated by the secondary-side variable frequency rectifier.

An isolation switch and circuit breaker are installed inside the high-voltage switch to disconnect the control power supply and load current. The main power source is monitored and fault isolation is performed using a comprehensive protection system with PLC. The auxiliary transformer is protected against overcurrent using fuses.

The low-voltage switch employs a dual-circuit design and utilizes two PLC comprehensive protection systems to monitor and check each other, completing equipment operation monitoring and fault isolation.

Both high and low-voltage switches communicate with the downstream variable frequency inverters, enabling phase-locking and interlocking functions to prevent equipment damage due to operational errors.

Feature

  • High-efficiency Heat Dissipation:Patented full-corrugated cylindrical structure prevents water and dust accumulation on the top, ensuring excellent heat dissipation performance.

  • Effective Explosion Protection:The shell can withstand a pressure of 1MPa, providing superior flameproof performance.

  • Low Loss and Low Noise:Partial discharge quantity is less than 5pC, which improves product reliability with low noise operation.

Main parameters

Model

Rated Capacity (kVA)

primary voltage

Secondary voltage

The connection group designation number

Loss of empty load

Load loss

Short-circuit impedance

No-load current

L

B

H

Theoretical weight kg

KBSGZY2-T-50/6

50

6000±5%

693/400 1200/693

Yy0(d11)

350

550

4

2.5

3620

840

990

2275

KBSGZY2-T-80/6

80

6000±5%

693/400 1200/693

Yy0(d11)

450

780

4

2.5

3620

840

990

2440

KBSGZY2-T-100/6

100

6000±5%

693/400 1200/693

Yy0(d11)

520

920

4

2.5

3620

840

990

2480

KBSGZY2-T-125/6

125

6000±5%

693/400 1200/693

Yy0(d11)

600

1080

4

2.5

3620

840

990

2665

KBSGZY2-T-160/6

160

6000±5%

693/400 1200/693

Yy0(d11)

700

1300

4

2

3995

1175

1385

2765

KBSGZY2-T-200/6

200

6000±5%

693/400 1200/693

Yy0(d11)

820

1500

4

2

3995

1175

1385

2905

KBSGZY2-T-250/6

250

6000±5%

693/400 1200/693

Yy0(d11)

950

1800

4

2

4055

1175

1385

3070

KBSGZY2-T-315/6

315

6000±5%

693/400 1200/693

Yy0(d11)

1100

2150

4

1.8

4055

1175

1385

3365

KBSGZY2-T-400/6

400

6000±5%

693/400 1200/693

Yy0(d11)

1300

2600

4

1.8

4100

1175

1425

3640

KBSGZY2-T-500/6

500

6000±5%

693/400 1200/693

Yy0(d11)

1500

3100

4

1.5

4115

1175

1425

3715

KBSGZY2-T-630/6

630

6000±5%

693/400 1200/693

Yy0(d11)

1800

3680

4

1.5

4175

1175

1425

4230

KBSGZY2-T-800/6

800

6000±5%

1200/693 3450

yy0(d11) Yyn0

2050

4500

4

1

4265

1175

1425

4505

KBSGZY2-T-1000/6

1000

6000±5%

1200/693 3450

yy0(d11) Yyn0

2350

5400

4

1

4265

1175

1450

5170

KBSGZY2-T-1250/6

1250

6000±5%

1200/693 3450

yy0(d11) Yyn0

2750

6500

4

1

4390

1350

1600

5705

KBSGZY2-T-1600/6

1600

6000±5%

1200/693 3450

yy0(d11) Yyn0

3350

8000

4

0.8

4610

1190

1805

8480

KBSGZY2-T-2000/6

2000

6000±5%

1200

yy0(d11) Yyn0

3800

9500

4.5

0.6

4780

1220

1870

9750

KBSGZY2-T-2500/6

2500

6000±5%

3450

yy0(d11) Yyn0

4500

10600

5

0.6

4780

1220

1985

10725

KBSGZY2-T-3150/6

3150

6000±5%

3450

Dyn11

5300

12500

5.5

0.6

5740

1310

2055

12980

KBSGZY2-T-4000/6

4000

6000±5%

3450

Dyn11

6100

14000

6

0.6

5740

1310

2055

15120

KBSGZY2-T-50/10

50

10000±5%

693/400 1200/693

Yy0(d11)

390

680

4

2.5

3930

1030

1265

2725

KBSGZY2-T-80/10

80

10000±5%

693/400 1200/693

Yy0(d11)

490

880

4

2.5

3930

1030

1265

2785

KBSGZY2-T-100/10

100

10000±5%

693/400 1200/693

Yy0(d11)

560

1050

4

2.5

3930

1030

1265

2910

KBSGZY2-T-125/10

125

10000±5%

693/400 1200/693

Yy0(d11)

650

1300

4

2.5

3930

1030

1265

3000

KBSGZY2-T-160/10

160

10000±5%

693/400 1200/693

Yy0(d11)

800

1500

4

2

3980

1030

1265

3290

KBSGZY2-T-200/10

200

10000±5%

693/400 1200/693

Yy0(d11)

950

1800

4

2

4175

1030

1520

3400

KBSGZY2-T-250/10

250

10000±5%

693/400 1200/693

Yy0(d11)

1100

2100

4

2

4175

1030

1520

3530

KBSGZY2-T-315/10

315

10000±5%

693/400 1200/693

Yy0(d11)

1300

2500

4

1.8

4175

1030

1520

3500

KBSGZY2-T-400/10

400

10000±5%

693/400 1200/693

Yy0(d11)

1500

3000

4

1.8

4220

1090

1555

3985

KBSGZY2-T-500/10

500

10000±5%

693/400 1200/693

Yy0(d11)

1750

3500

4

1.5

4220

1260

1555

4445

KBSGZY2-T-630/10

630

10000±5%

693/400 1200/693

Yy0(d11)

2000

4100

4

1.5

4280

1260

1555

4685

KBSGZY2-T-800/10

800

10000±5%

1200/693 3450

yy0(d11) Yyn0

2300

5100

4

1.2

4345

1260

1555

4905

KBSGZY2-T-1000/10

1000

10000±5%

1200/693 3450

yy0(d11) Yyn0

2600

6100

4.5

1.2

4375

1330

1585

5505

KBSGZY2-T-1250/10

1250

10000±5%

1200/693 3450

yy0(d11) Yyn0

3100

7400

4.5

1

4420

1370

1610

5895

KBSGZY2-T-1600/10

1600

10000±5%

1200/693 3450

yy0(d11) Yyn0

3800

8500

5

1

4890

1270

1805

8600

KBSGZY2-T-2000/10

2000

10000±5%

1200

Yy0 Yyn0

4500

9700

5

0.7

4960

1270

1825

10720

KBSGZY2-T-2500/10

2500

10000±5%

3450

Yy0 Yyn0

5200

10800

5.5

0.7

4965

1270

2025

11490

KBSGZY2-T-3150/10

3150

10000±5%

3450

Dyn11

6100

12800

5.5

0.7

5065

1320

2095

13400

KBSGZY2-T-4000/10

4000

10000±5%

3450

Dyn11

7000

15000

6

0.7

5800

1320

2095

17500

KBSGZY2-T-5000/10

5000

10000±5%

3450

Dyn11

8200

17600

6.5

0.6

5980

1490

2150

20550

KBSGZY2-T-6300/10

6300

10000±5%

3450

Dyn11

9500

20000

7

0.6

5980

1490

2150

26000

 

Model

Rated Capacity (kVA)

primary voltage

Secondary voltage

The link group designation

Loss of empty load

Load loss

Short-circuit impedance

No-load current

L

B

H

KBSGZY-ZT-1600/6/2x1.903

1600

6000±5%

2x1.903

Qd0y11

3800

9500

7.5

0.6

5370

1180

1085

KBSG2Y-ZT-1600/10/2x1.903

1600

10000±5%

2x1.903

Qd0y11

4500

9700

7.5

0.7

5690

1260

1085

KBSGZY-ZT-2000/6/2x1.903

2000

6000±5%

2x1.903

Qd0y11

4500

10600

8

0.6

5410

1210

1085

KBSGZY-ZT-2000/10/2x1903

2000

10000±5%

2x1.903

Qd0y11

5200

10800

8

0.7

5760

1260

1085

KBSGZY-ZT-2500/6/2x1.903

2500

6000±5%

2x1.903

Qd0y11

5300

12500

8

0.6

5645

1260

2025

KBSGZY-ZT-2500/10/2x1.903

2500

10000±5%

2x1.903

Qd0y11

6100

12800

8

0.7

5845

1260

2025

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
1.Flame-Retardant Cable Classification StandardsThe flame-retardant standard system is divided into two main categories. The first category follows the "Classification of Burning Behavior for Electric and Optical Fiber Cables" GB 31247. Cables complying with this standard system are widely used in densely populated areas such as high-speed railways and subways. This standard imposes strict requirements on parameters such as smoke density, heat release, and total smoke production, and cables typi
James
09/03/2025
Repair of high-voltage cable metallic sheaths
Repair of high-voltage cable metallic sheaths
I. Functions of Metallic Sheaths and Necessity of RepairThe metallic sheath of high-voltage cables is a metal shielding structure laid outside the insulation layer, including types such as lead sheaths, aluminum sheaths, and steel wire armor. Its core functions include mechanical protection (resisting external impact and compression), electrochemical corrosion protection (isolating moisture and soil pollutants), electromagnetic shielding (reducing electromagnetic interference to the environment)
Felix Spark
09/03/2025
What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge
Edwiin
09/02/2025
A hybrid DC circuit breaker
A hybrid DC circuit breaker
Most DC molded-case circuit breakers use natural air arc extinction, and there are typically two arc extinguishing methods: one is conventional opening and closing, where the contacts axially stretch the arc, while the conductive circuit generates a magnetic field that bends and elongates the arc, pulling it lengthwise perpendicular to the arc axis. This not only increases the arc length but also induces lateral motion, enabling air cooling to achieve arc extinction.The other method involves the
Echo
09/02/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!