• KBSG series Mining Flameproof Dry-Type Transformer
  • KBSG series Mining Flameproof Dry-Type Transformer
KBSG series Mining Flameproof Dry-Type Transformer
discuss personally
Model
KBSGZY2-T-1250/6
Basic info
Brand ROCKWILL
Model NO. KBSG series Mining Flameproof Dry-Type Transformer
Rated frequency 50/60Hz
Rated capacity 1250kVA
Series KBSG
Product Detail

Product Introduction

The KBSG series mining flameproof dry-type transformers innovatively adopt active heat dissipation pipes, which slow down the aging rate of insulating materials and enhance the reliability and stability of the products. They are suitable not only for underground mines with gas, coal dust and explosion hazards, but also for gas-containing tunnel mining, mobile working faces of non-coal mines and other environments.

Feature

  • Low Loss and Low Noise:Partial discharge quantity is less than 5pC, which improves product reliability with low noise.

  • Efficient Heat Dissipation:Additional active heat dissipation pipes and an innovative zoned heat dissipation structure enhance the transformer's heat dissipation performance, slow down the aging rate of insulating materials, and strengthen the product's reliability and stability.

  • Effective Flame Retardancy:The arc-shaped corrugations on the top and non-closed side edges prevent coal dust accumulation, achieve effective flame retardancy, and improve safety.

  • Excellent Flameproof Performance:The cylindrical flameproof enclosure enhances shell strength; the shell can withstand a pressure of 1MPa, with superior flameproof performance.

Main parameters

Model

Rated Capacity (kVA)

primary voltage

Secondary voltage

The connection group designation number

Loss of empty load

Load loss

Short-circuit impedance

No-load current

L

B

H

Theoretical weight kg

KBSGZY2-T-50/6

50

6000±5%

693/400 1200/693

Yy0(d11)

350

550

4

2.5

2215

840

860

1275

KBSGZY2-T-80/6

80

6000±5%

693/400 1200/693

Yy0(d11)

450

780

4

2.5

2215

840

860

1440

KBSGZY2-T-100/6

100

6000±5%

693/400 1200/693

Yy0(d11)

520

920

4

2.5

2215

840

860

1480

KBSGZY2-T-125/6

125

6000±5%

693/400 1200/693

Yy0(d11)

600

1080

4

2.5

2215

840

860

1665

KBSGZY2-T-160/6

160

6000±5%

693/400 1200/693

Yy0(d11)

700

1300

4

2

2535

930

1020

1765

KBSGZY2-T-200/6

200

6000±5%

693/400 1200/693

Yy0(d11)

820

1500

4

2

2535

930

1020

1905

KBSGZY2-T-250/6

250

6000±5%

693/400 1200/693

Yy0(d11)

950

1800

4

2

2595

930

1020

2070

KBSGZY2-T-315/6

315

6000±5%

693/400 1200/693

Yy0(d11)

1100

2150

4

1.8

2595

930

1020

2455

KBSGZY2-T-400/6

400

6000±5%

693/400 1200/693

Yy0(d11)

1300

2600

4

1.8

2640

1030

1130

2640

KBSGZY2-T-500/6

500

6000±5%

693/400 1200/693

Yy0(d11)

1500

3100

4

1.5

2655

1030

1130

2715

KBSGZY2-T-630/6

630

6000±5%

693/400 1200/693

Yy0(d11)

1800

3680

4

1.5

2715

1090

1165

3195

KBSGZY2-T-800/6

800

6000±5%

1200/693 3450

Yy0(d11) Yyn0

2050

4500

4

1

2805

1150

1245

3505

KBSGZY2-T-1000/6

1000

6000±5%

1200/693 3450

Yy0(d11) Yyn0

2350

5400

4

1

2840

1250

1350

4170

KBSGZY2-T-1250/6

1250

6000±5%

1200/693 3450

Yy0(d11) Yyn0

2750

6500

4

1

2870

1350

1445

4705

KBSGZY2-T-1600/6

1600

6000±5%

1200/693 3450

Yy0(d11) Yyn0

3350

8000

4

0.8

3140

1140

1635

7480

KBSGZY2-T-2000/6

2000

6000±5%

1200

Yy0(d11) Yyn0

3800

9500

4.5

0.6

3300

1220

1700

8750

KBSGZY2-T-2500/6

2500

6000±5%

3450

Yy0(d11) Yyn0

4500

10600

5

0.6

3300

1220

1815

9725

KBSGZY2-T-3150/6

3150

6000±5%

3450

Dyn11

5300

12500

5.5

0.6

4220

1310

1880

11980

KBSGZY2-T-4000/6

4000

6000±5%

3450

Dyn11

6100

14000

6

0.6

4220

1310

1880

14120

KBSGZY2-T-50/10

50

10000±5%

693/400 1200/693

Yy0(d11)

390

680

4

2.5

2390

1030

1090

1625

KBSGZY2-T-80/10

80

10000±5%

693/400 1200/693

Yy0(d11)

490

880

4

2.5

2390

1030

1090

1690

KBSGZY2-T-100/10

100

10000±5%

693/400 1200/693

Yy0(d11)

560

1050

4

2.5

2390

1030

1090

1810

KBSGZY2-T-125/10

125

10000±5%

693/400 1200/693

Yy0(d11)

650

1300

4

2.5

2390

1030

1090

1900

KBSGZY2-T-160/10

160

10000±5%

693/400 1200/693

Yy0(d11)

800

1500

4

2

2440

1030

1130

2190

KBSGZY2-T-200/10

200

10000±5%

693/400 1200/693

Yy0(d11)

950

1800

4

2

2440

1030

1130

2300

KBSGZY2-T-250/10

250

10000±5%

693/400 1200/693

Yy0(d11)

1100

2100

4

2

2655

1030

1130

2430

KBSGZY2-T-315/10

315

10000±5%

693/400 1200/693

Yy0(d11)

1300

2500

4

1.8

2655

1030

1130

2670

KBSGZY2-T-400/10

400

10000±5%

693/400 1200/693

Yy0(d11)

1500

3000

4

1.8

2700

1090

1190

2860

KBSGZY2-T-500/10

500

10000±5%

693/400 1200/693

Yy0(d11)

1750

3500

4

1.5

2700

1150

1240

3300

KBSGZY2-T-630/10

630

10000±5%

693/400 1200/693

Yy0(d11)

2000

4100

4

1.5

2760

1150

1240

3640

KBSGZY2-T-800/10

800

10000±5%

1200/693 3450

Yy0(d11) Yyn0

2300

5100

4

1.2

2825

1250

1340

3805

KBSGZY2-T-1000/10

1000

10000±5%

1200/693 3450

Yy0(d11) Yyn0

2600

6100

4.5

1.2

2855

1330

1425

4405

KBSGZY2-T-1250/10

1250

10000±5%

1200/693 3450

Yy0(d11) Yyn0

3100

7400

4.5

1

2900

1370

1470

4795

KBSGZY2-T-1600/10

1600

10000±5%

1200/693 3450

Yy0(d11) Yyn0

3800

8500

5

1

3345

1140

1635

7500

KBSGZY2-T-2000/10

2000

10000±5%

1200

Yy0 Yyn0

4500

9700

5

0.7

3415

1220

1655

9620

KBSGZY2-T-2500/10

2500

10000±5%

3450

Yy0 Yyn0

5200

10800

5.5

0.7

3425

1220

1855

10390

KBSGZY2-T-3150/10

3150

10000±5%

3450

Dyn11

6100

12800

5.5

0.7

3590

1320

1925

12300

KBSGZY2-T-4000/10

4000

10000±5%

3450

Dyn11

7000

15000

6

0.7

4260

1320

1925

15605

Note: The size, weight, etc. provided by the above parameters are only for design and selection, and the final data is subject to the product delivery

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
1.Flame-Retardant Cable Classification StandardsThe flame-retardant standard system is divided into two main categories. The first category follows the "Classification of Burning Behavior for Electric and Optical Fiber Cables" GB 31247. Cables complying with this standard system are widely used in densely populated areas such as high-speed railways and subways. This standard imposes strict requirements on parameters such as smoke density, heat release, and total smoke production, and cables typi
James
09/03/2025
Repair of high-voltage cable metallic sheaths
Repair of high-voltage cable metallic sheaths
I. Functions of Metallic Sheaths and Necessity of RepairThe metallic sheath of high-voltage cables is a metal shielding structure laid outside the insulation layer, including types such as lead sheaths, aluminum sheaths, and steel wire armor. Its core functions include mechanical protection (resisting external impact and compression), electrochemical corrosion protection (isolating moisture and soil pollutants), electromagnetic shielding (reducing electromagnetic interference to the environment)
Felix Spark
09/03/2025
What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge
Edwiin
09/02/2025
A hybrid DC circuit breaker
A hybrid DC circuit breaker
Most DC molded-case circuit breakers use natural air arc extinction, and there are typically two arc extinguishing methods: one is conventional opening and closing, where the contacts axially stretch the arc, while the conductive circuit generates a magnetic field that bends and elongates the arc, pulling it lengthwise perpendicular to the arc axis. This not only increases the arc length but also induces lateral motion, enabling air cooling to achieve arc extinction.The other method involves the
Echo
09/02/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!