• Compact and Prefabricated Substation
Compact and Prefabricated Substation
discuss personally
Model
SHN-1000-2
Basic info
Brand ROCKWILL
Model NO. Compact Substation Prefabricated Substation
Rated voltage 35kV
Rated normal current 5000A
Series Compact Substation
Product Detail

Product overview

Compact substations, mini substations, and prefabricated substations are innovative alternatives to traditional indoor substations. These advanced units are engineered to fulfill diverse user requirements, including electric energy measurement, reactive power compensation, and customized high and low voltage configurations. They embody the future of small and medium-sized power distribution infrastructure.

Technical Specifications 

  • Electrical Parameters: Rated for AC frequencies of 50Hz/60HZ, with a maximum operating voltage of 35KV and a maximum operating current of 5000A. 

  • Wide Application: Ideal for industrial and mining enterprises, ports, public facilities, high-rise buildings, and residential communities. Our products have a strong global footprint, predominantly exported to Asia, Africa, and other regions. We also offer comprehensive OEM/ODM services to meet unique client needs.

  •  Standards Compliance: Adheres to international and national standards such as IEC60067 and GB 17467-2010, ensuring quality and reliability.

Product Advantages 

  • Cutting-edge Technology: Boasting a fully enclosed and insulated structure, these substations ensure safe and reliable operation. They are user-friendly, virtually maintenance-free, and offer cost-effective solutions with low equipment investment. 

  • Robust Shell Design: The casing features excellent durability, thermal insulation, and ventilation. It demonstrates stable performance in various environments, with corrosion resistance, dustproof, and waterproof properties, while maintaining an aesthetically pleasing appearance. Multiple shell materials are available, including steel plates, composite plates, stainless steel plates, and cement plates, with protection grades up to IP67. 

Functional Configuration 

Independent Compartments: 

  • Divided into three separate areas: high voltage room, low voltage room, and transformer room. 

  • High Voltage Room: Equipped with XGN15, HXGN17, or SF6 switchgear, ensuring efficient high-voltage management. Low Voltage Side: Utilizes panel or cabinet-mounted structures, enabling the creation of customized power supply schemes. It supports functions like power distribution, lighting control, reactive power compensation, and energy metering. The main switch can be a universal circuit breaker or an intelligent circuit breaker, providing flexible installation and easy operation. 

  • Transformer Options: Available with fully sealed oil-immersed transformers or dry type transformers to suit different application needs. 

  • Superior Busbar System: Supports three-phase four-wire or three-phase five-wire systems. Constructed from high-quality three-phase tinned copper busbars, it offers high mechanical strength and excellent heat dissipation capabilities.

Operating Conditions 

  • Temperature: Ambient air temperature ranges from -45 °C to 45 °C. 

  • Altitude: Suitable for altitudes up to 1000m; can be extended to 4000m with customized transformers and low-voltage components. 

  • Installation: Recommended for installation with a vertical inclination not exceeding 5°, in environments free from severe vibrations and impacts. 

  • Humidity: Operational in air humidity levels of up to 90% at +25℃.

  •  Environmental Requirements: Designed for use in areas without conductive dust, explosion hazards, or gases that could corrode metal and electrical components. Outdoor installations should be in locations where wind speeds do not exceed 35m/s. For conditions outside these norms, we offer custom solutions tailored to your specific requirements.

Ordering Guidelines 

When placing an order, please provide the following details:

 Main loop scheme diagram and secondary loop system diagram. Electrical schematic diagram of the auxiliary circuit and wiring terminal layout. Equipment layout drawing, combination drawing, and floor plan drawing. Model, specification, and quantity of main electrical components. Incoming and outgoing line methods and cable specifications. Preferred equipment shell material and color. Any other special requirements can be discussed and accommodated through direct negotiation with our manufacturing team. 

We warmly invite customers to visit our factory. With our OEM/ODM services, we can also customize the protection level according to your specific project demands.

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
What are the common faults of low-voltage voltage transformers?
What are the common faults of low-voltage voltage transformers?
1. Open - Circuit Fault on the Secondary SideOpen - circuit in the secondary side is a typical fault of low - voltage voltage transformers, showing abnormal voltmeter readings (zero/fluctuation), faulty power meters, buzzing noises, and core overheating. When open - circuited, the secondary voltage spikes (no secondary current to balance the primary EMF), causing core saturation, flux distortion, and potential overheating/damage.Causes include loose terminals, poor contact, or human error. In lo
Oliver Watts
07/16/2025
A Quick Verification Method for Low-Voltage Current Transformers
A Quick Verification Method for Low-Voltage Current Transformers
1. Selection of Low - Voltage Current Transformer ConfigurationThere are many factors leading to wrong selection of low - voltage current transformers in civil construction projects. For example, common factors include design problems: the calculated coefficient designed for the load of electrical equipment is relatively large, or the transformation ratio of the current transformer is selected incorrectly. Such a series of reasons will affect the use of electrical equipment. Therefore, in the co
James
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!