Center Vee Switch Unitized for Wind Power Substations

  • Center Vee Switch Unitized for Wind Power Substations

Key attributes

Brand ROCKWILL
Model NO. Center Vee Switch Unitized for Wind Power Substations
Rated voltage 145kV
Rated normal current 4000A
Series RDS
Description

The Center Vee Switch Unitized is a high-voltage switching device with a double-column V-type structure design. It is mainly used for circuit switching and electrical isolation under no-load conditions in power systems, and has significant advantages especially in scenarios such as wind power and substations.

Features

  • Fully Assembled and adjusted prior to shipment for quick installation

  • Rotating Blade Mechanisn

  • Reverse Loop Contacts

  • Laminated Shunt Hinge

  • Double Row Stainless Steel Bearing

Technical Parameters

Parameter (IEC Terminology) Specification / Rating
Equipment Type Outdoor Double-Column Center Break V-Type Disconnector
Rated Voltage (Ur​) 12kV / 24kV / 36kV / 72.5kV / 126kV / 145kV
Rated Normal Current (Ir​) 3150A / 4000A (Aligned with the 3000A–4000A range)
Rated Frequency (fr​) 50 Hz / 60 Hz
Rated Short-time Withstand Current (Ik​) 40 kA / 50 kA / 63 kA (for 3 seconds)
Rated Peak Withstand Current (Ip​) 100 kA / 125 kA / 160 kA
Rated Lightning Impulse Withstand Voltage (BIL) To earth and between poles: up to 650 kV (for 145kV)
Across the isolating distance: up to 730 kV
Rated Power-frequency Withstand Voltage (1 min) To earth and between poles: up to 275 kV (for 145kV)
Across the isolating distance: up to 315 kV
Mechanical Endurance Class Class M2 (10,000 extended mechanical operating cycles)
Contact Design Reverse Loop Contacts (Self-locking electromagnetic force under short-circuit currents)
Hinge Design Laminated Shunt Hinge
Mechanism & Bearings Rotating Blade Mechanism with Double Row Stainless Steel Bearing
Interrupter Attachments Compatible with Turner TECORupter (For switching bus-transfer currents, small capacitive/inductive currents)
Installation Status Fully Assembled and adjusted prior to shipment (Unitized)

Environmental Conditions

  • Ambient Air Temperature: -40°C to +40°C (Capable of carrying 4000A full load at maximum temperature).
  • Altitude: ≤ 1000m (Standard); versions with reinforced insulation available for high-altitude applications (2000m or 3000m).
  • Maximum Wind Speed: 34 m/s (equivalent to 700 Pa wind pressure on cylindrical surfaces), suitable for high-wind installation sites.
  • Ice Coating: 10 mm or 20 mm (Maintains operability for ice-breaking due to the rotating blade mechanism).
  • Humidity: Average daily relative humidity ≤ 95%, average monthly relative humidity ≤ 90%.
  • Seismic Withstand Capability: Horizontal acceleration 0.3g, Vertical acceleration 0.15g.
  • Site Pollution Severity (SPS): Heavy (Class III) or Very Heavy (Class IV), with a nominal creepage distance of ≥ 25 mm/kV or 31 mm/kV.

Documentation Resource Library Disconnector

Restricted
12 to 550kV Center Side Break Disconnect Switch Installation and Instruction Manuals 12 to 550kV Center Side Break Disconnect Switch Installation and Instruction Manuals
Installation Manual
English
PDF
Restricted
12 to 800kV Center Vee Center Break Disconnect Switch Installation and Instruction Manuals 12 to 800kV Center Vee Center Break Disconnect Switch Installation and Instruction Manuals
Installation Manual
English
PDF
Restricted
252 to 1100kV Double End Break Disconnect Switch Installation and Instruction Manuals 252 to 1100kV Double End Break Disconnect Switch Installation and Instruction Manuals
Installation Manual
English
PDF
Public.
Rockwill Electric Group Profile Rockwill Electric Group Profile
Brochure
English

Frequently asked questions

No, it is fully assembled and adjusted prior to shipment, which significantly reduces on-site installation time and labor costs.

It features reverse loop contacts that generate a self-locking electromagnetic force during short circuits, preventing the contacts from blowing open. 

Yes, the double-column Center Vee structure requires a significantly smaller footprint than traditional designs, making it ideal for space-constrained upgrades.

Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m² Total staff: 700+ Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Medium and High Voltage Switchgear/Power and Distribution Transformers/Instrument Transformers and Sensors/Lightning Protection and Electrical Insulation/Substations and E-Houses/Electrical Panel and Controlgear
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application