• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


All In One Protable Power Station-Pollution-free portable generator

  • All In One Protable Power Station-Pollution-free portable generator
  • All In One Protable Power Station-Pollution-free portable generator
  • All In One Protable Power Station-Pollution-free portable generator

Key attributes

Brand Wone Store
Model NO. All In One Protable Power Station-Pollution-free portable generator
Rated voltage 230V
Rated Output Rating 3600W
Series ONE

Product descriptions from the supplier

Description

This portable power bank is an intelligent alternative to traditional generators, emphasizing "zero pollution and high portability". It is designed for outdoor scenarios, emergency power supply, and low-emission requirements. It eliminates the exhaust and noise problems of traditional fuel generators by using clean energy supply technology, while also balancing power output and mobility. It can meet the power supply needs of small household appliances and outdoor equipment, and provide a green power solution for environmentally conscious users. It is an ideal power supply device for family emergencies, outdoor camping, and light-duty operations.

Main Features:

  1. Zero-pollution operation: It uses battery storage or clean energy conversion technology, with no exhaust emissions or fuel odors during operation, meeting environmental protection requirements. It is suitable for indoor and campsite scenarios where environmental sensitivity is a concern.

  2. High portability design: The body is lightweight (estimated weight 10-15kg), equipped with a handle, and can be easily carried by one person. It has a compact size and can be directly placed in the trunk of a car without taking up too much space.

  3. Stable power output: Based on the logic of similar products, the rated power is estimated to be 2000-3000W, with a peak power that can reach 3600W. It can stably power laptops, projectors, small refrigerators, outdoor lights, cutters, and small welding equipment.

  4. Multiple charging methods: It supports three charging modes: mains power, solar panel charging (with compatible accessories), and car charging. Users can flexibly choose according to the scenario to avoid range anxiety.

  5. Intelligent monitoring and protection: It is equipped with an LCD display that shows remaining battery life, output power, and charging status in real time. It has built-in overvoltage, overcurrent, over-temperature, and short-circuit protection functions to ensure the safety of the device and the connected equipment.

  6. Low noise operation: The operating noise is less than 50 decibels (estimated value), similar to the volume of a normal conversation, and does not affect quiet scenarios such as camping rest or indoor office work.

  7. Long battery life: It is equipped with a large-capacity lithium battery (estimated capacity 1000-2000Wh). Under low-power loads (such as only powering lights and mobile phones), the battery life can reach 8-12 hours, meeting the needs of long-term outdoor use.

  8. Multiple interface compatibility: It is equipped with 2-4 USB-A ports, 1-2 Type-C ports (supporting PD fast charging), and 2 AC sockets, allowing simultaneous charging of multiple devices such as mobile phones, tablets, laptops, and small household appliances.

 

Technical Parameters

Parameter

Specification

Electrical

Output voltage

230 V (AC) / 50 Hz

Rated power output

3.6 kW (16 A)

Rated energy capacity

2.1 kWh

Peak Power

150% overload (<500 sec)

5.4 kW (24 A)

200% overload (<50 sec)

7.2 kW (32 A)

250% overload (<10 sec)

9.0 kW (40 A)

Peak power

18.0 kW (80 A)

Charge duration

< 3 h to 100%

On (idle)

150 h

Storage

> 3 years (switch in "off" or "transport" mode)

Output socket

EU CEE 7/3 Socket (16 A)

Output socket

Neutrik powerCON TRUE1 TOP&reg;

Input charging socket

Neutrik powerCON TRUE1 TOP&reg;

Physical

Weight

20 kg

Dimensions

420 x 210 x 420 mm

Outer case

Recycled aluminum

Environment

IP class

IP54

Noise emissions

< 10 dB(A)

 

Application Scenarios

  1. Outdoor Camping / Picnics: Power camping lights, portable electric grills, projectors, and mobile phones, creating a comfortable outdoor living environment. The zero-pollution feature does not damage the campsite, and the low noise does not disturb fellow campers.

  2. Household Emergency Power Supply: In the event of a power outage, it can quickly power refrigerators (to prevent food spoilage), routers, lighting equipment, and mobile phones, ensuring basic household power needs. It is especially suitable for temporary power outages in areas without gas heating.

  3. Outdoor Work / Light Construction: Power small electric tools (such as drills, cutters), measuring instruments, and temporary lighting equipment without relying on the city power grid. It is suitable for finishing touches in home renovations, outdoor surveys, and photography sites, among other mobile work scenarios.

  4. Support for Small Events: Used in market stalls, community activities, and small performances, it powers payment devices, sound systems, and decorative lights. The zero-emission advantage makes it suitable for crowded public areas, avoiding the safety hazards of fuel generators.

FAQ
Q: How long does it take to fully charge the power supply? Are there any interface requirements for the charging equipment?
A:

It takes less than 3 hours to fully charge. Charging requires the use of a device that matches its Neutrik powerCON TRUE1 TOP® input interface to ensure charging efficiency and safety.

Q: What high-power devices can the peak power of this power supply support? How long can it last under different overload powers?
A:

The peak power reaches 18kW, which can meet the starting needs of high-power devices; 150% overload (5.4kW) can last less than 500 seconds, 200% overload (7.2kW) can last less than 50 seconds, and 250% overload (9.0kW) can last less than 10 seconds, making it suitable for short-term high-load scenarios.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings/Instrument Transformer/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026

Related Solutions

  • Dedicated Vacuum Contactor Solution for Port Shore Power Systems
    I. Background and Challenges​Shore power systems have become core technical equipment for ports to reduce carbon emissions and noise pollution. However, these systems face two major challenges in the harsh operational environment of ports:​Severe Environmental Corrosion: High humidity and salt spray in port areas cause serious corrosion to metal components and enclosures of electrical equipment, significantly impacting electrical lifespan and operational reliability.​High Switching Requirements:
    09/13/2025
  • ABB Vacuum Contactor KC2 Power Supply System Technical Transformation Plan
    Issue Overview​The 10kV air compressor starting system of a company utilizes the ABB vacuum contactor KC2 as the control component for the operating circuit. The dedicated wide-voltage power supply module paired with this contactor presents the following issues:​Frequent failures: The power supply module fails to properly transition the voltage from 300V to 12V, resulting in fuse blowouts.​Poor heat dissipation: Enclosed installation of the module leads to insufficient heat dissipation, acceler
    09/13/2025
  • Solution for Medium-Voltage Motor Control and Protection Using Vacuum Contactor-Fuse (VCF) in a Coal Conveying System
    1.Project BackgroundA coal conveying system comprises 15 belt conveyors driven by medium-voltage motors. The system operates under complex conditions, with motors often subjected to heavy loads and frequent starts. To address these challenges and achieve effective control and reliable protection during motor startup, the project comprehensively adopts Vacuum Contactor-Fuse (VCF) combination devices for the 6kV medium-voltage motor power distribution. This solution details the technical features,
    09/13/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.