Metal Enclosed Capacitor Banks supplier

Add us on Google
  • Metal Enclosed Capacitor Banks supplier

Key attributes

Brand ROCKWILL
Model NO. Metal Enclosed Capacitor Banks supplier
Rated voltage 12kV
Rated frequency 50/60Hz
Capacity 30 MVAr
Series ACUS-E
Description

Metal enclosed capacitor bank is a modular, compact reactive power compensation cabinet. It can be configured as fixed or multi-step switched type. The switched version automatically switches stages to optimize power factor. The whole set is fully assembled and factory tested before delivery.

It integrates primary power components, control, protection and auxiliary equipment inside one metal enclosure. It suits indoor and outdoor installation for power utilities, renewable energy plants and heavy industrial users.

Working Principle

The metal enclosed capacitor bank injects controllable capacitive reactive power into the grid to offset inductive reactive power from loads. Fixed banks stay continuously energized. Multi-step switched banks receive signals from the power factor controller, switching contactors stage by stage.

It stabilizes voltage, improves power factor, reduces line losses and mitigates harmonic issues with optional detuning or filter reactors. Comprehensive protection relays monitor current, voltage, unbalance and earth faults to guarantee safe operation.

Why Choose Us?

We provide fully factory assembled and tested metal enclosed capacitor banks, complying with IEC, IEEE/ANSI, CSA international standards. Modular design separates incoming unit, power unit and control cubicle, easy for maintenance and future expansion.

The enclosure material options include corrosion-resistant aluminum, galvanized steel or stainless steel, with IP65 / NEMA 4X high protection grade for outdoor harsh environments. Complete protection suite covers overcurrent, earth fault, unbalance, over/under voltage and arc fault mitigation.

All copper busbars are tinned hard drawn copper for reliable conductivity. We support customized capacity, voltage and seismic/wind resistance requirements for mining, chemical, solar and wind farm projects.

Key Features

  • Compact modular metal enclosure, integrated primary & secondary equipment
  • Two configuration: fixed type or multi-step automatic switched type
  • Indoor & outdoor applicable, high IP65 / NEMA 4X enclosure protection
  • Tinned hard drawn copper busbar, stable current transmission
  • Complete protection relays: overcurrent, earth fault, unbalance, over & under voltage
  • Optional arc fault mitigation, mechanical/solenoid interlock
  • Built-in discharge resistors for capacitors, low loss polypropylene film capacitor elements
  • Optional inrush, detuning or filter reactors to suppress inrush current and harmonics
  • Auxiliary components: cabinet heaters, cooling fans, thermostats, safety interlocks
  • Seismic and wind resistant design available for heavy industry and renewable sites
  • Factory pre-assembled and tested, short on-site installation period

Module Composition

Incomer Module

  • Incoming cable termination busbars
  • Air-insulated isolator and earth switch
  • Surge arresters
  • Circuit breakers
  • Protection voltage transformers & line current transformers
  • Control voltage transformers
  • Live line indicator

Power Module

  • Single / three phase capacitors
  • Inrush reactors, detuning or filter reactors
  • HRC fuses
  • Vacuum contactors
  • Pressure switches
  • Earthing stick
  • Safety interlocks
  • Cabinet lights, heaters, cooling fans, thermostats

Control Cubicle

  • Microprocessor power factor controller with Modbus communication
  • Safety interlock keys
  • Overcurrent & earth fault protection relay
  • Capacitor unbalance protection relay
  • Overload, overvoltage & undervoltage protection relay
  • Local / remote, manual / automatic switching function

Technical Specifications

Category Item Parameter
General Rated Voltage Up to 12 kV
Maximum Output Capacity Up to 30 Mvar
Frequency 50 Hz / 60 Hz
Installation Location Indoor / Outdoor
Ambient Temperature -10 ℃ ~ +50 ℃
Altitude <1000 m
Humidity Max 90% RH, non-condensing
Insulation Level Up to 200 kV BIL
Short Circuit Withstand Current Up to 50 kA for 1 s
Bank Configuration Fixed, single-step or multi-step switched
Interlock Optional mechanical / solenoid interlock
Arc Fault Protection Optional arc fault mitigation
Busbar Tinned hard drawn copper
Applicable Standards IEC, IEEE/ANSI, CSA
Wind & Seismic Rating ASCE 7-10 wind, IEEE 693 seismic standard
Enclosure Enclosure Material Corrosion resistant AA aluminum, zinc-coated steel, stainless steel
Base Frame Hot dipped galvanized steel
Protection Class IP65 / NEMA 4X
Door Lock 3-point lock handle, 1/4 turn blind lock
Installation Base fixed mounting
Lifting Method Forklift & crane lifting from base
Cable Entry Bottom entry, optional side entry
Capacitor Unit Phase Type Single phase / Three phase
Fusing Internal fused or unfused
Discharge Resistor Built-in
Total Loss <0.15 W/kvar (including discharge resistors)
Dielectric Polypropylene film
Tank Material Stainless steel
Bushing Grey porcelain (1/2/3 bushings)
Reactor Inrush Reactor Single phase, air core
  Detuning / Filter Reactor Single / three phase, iron core or air core
Contactor Type Vacuum contactor, transient-free optional
Phase 3-phase
Rated Current 1250 A
Isolator & Earth Switch Type Air-insulated
Phase 3-phase
Rated Current 1250 A
HRC Fuse Rated Current Up to 315 A
Short Time Withstand Current Max 63 kA
Power Factor Controller Core Microprocessor, harmonic immunity
Control Voltage 100 VAC ~ 240 VAC
PF Setting Range 0.7 inductive ~ 0.7 capacitive

Note: Higher or lower ratings are available upon customized request.

Application Scenarios

Power distribution utilities, solar farms, wind farms, mining, pulp & paper, chemical, petrochemical, cement and other heavy industrial power supply systems.

Solutions - Capacitor Banks

Case Studies - Capacitor Banks

Documentation Resource Library Capacitor Banks

Rockwill Electric Group Profile
Public
Rockwill Electric Group Profile Rockwill Electric Group Profile
Brochure
English
Rockwill Ecosystem Profile
Public
Rockwill Ecosystem Profile Rockwill Ecosystem Profile
Profile
English
6 to 35kV Static Var Generator(SVG) Brochure
Restricted
6 to 35kV Static Var Generator(SVG) Brochure 6 to 35kV Static Var Generator(SVG) Brochure
Brochure
English
PDF
Power compensation equipment SVG/FC/APF Catalog
Restricted
Power compensation equipment SVG/FC/APF Catalog Power compensation equipment SVG/FC/APF Catalog
Catalogue
English
PDF
6 to 35kV Liquid-Cooled high performance SVG
Public
6 to 35kV Liquid-Cooled high performance SVG 6 to 35kV Liquid-Cooled high performance SVG
Operating Instruction
English
RWSVG Series Dynamic Reactive Power Compensation Device
Restricted
RWSVG Series Dynamic Reactive Power Compensation Device RWSVG Series Dynamic Reactive Power Compensation Device
Operating Instruction
English
PDF

Certifcations Capacitor Banks

  • ISO9001 quality management system certificate

Frequently asked questions

Yes. Arc fault mitigation system is an optional package for this capacitor bank. When internal arc faults occur, the system quickly detects the arc signal and triggers protection actions to limit arc energy and reduce hazards to on-site operators. We can provide arc flash calculation support and safety documentation to meet site electrical safety regulations for heavy industrial plants.

A detuning reactor is mainly used to detune the circuit away from harmonic resonance points and avoid harmonic amplification between the capacitor bank and grid.

A filter reactor works together with capacitors to form a tuned filter branch, which can actively absorb specific harmonic orders. Our engineers will analyze your on-site harmonic spectrum and recommend the proper reactor type and tuning scheme.

The modular design supports future expansion. If you reserve empty module compartments and control capacity during the initial order, you can add extra power stages later without replacing the whole cabinet. We can pre-reserve busbar interfaces and controller logic channels, and provide upgrade guidance and program adjustment service when you expand capacity.

A complete interlock logic is implemented for safety isolation. The isolator cannot be closed when the cabinet door is open; the cabinet door can only be opened after the earthing switch is closed. The capacitor built-in discharge resistors will drain residual voltage. The interlock system prevents mis-operation and accidental contact with live parts during inspection and maintenance.

Absolutely. We can carry out structural design and finite element calculation according to regional wind and seismic codes. The cabinet frame, base and fixing structure will be reinforced accordingly. We can provide structural calculation reports and supporting documents for wind farm owner review and approval.

Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m² Total staff: 700+ Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Medium and High Voltage Switchgear/Power and Distribution Transformers/Instrument Transformers and Sensors/Lightning Protection and Electrical Insulation/Substations and E-Houses/Electrical Panel and Controlgear

Comments

Share your question or perspective
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Login
or continue with
New here?
Register