| Brand | ROCKWILL |
| Model NO. | Metal Enclosed Capacitor Banks supplier |
| Rated voltage | 12kV |
| Rated frequency | 50/60Hz |
| Capacity | 30 MVAr |
| Series | ACUS-E |
Metal enclosed capacitor bank is a modular, compact reactive power compensation cabinet. It can be configured as fixed or multi-step switched type. The switched version automatically switches stages to optimize power factor. The whole set is fully assembled and factory tested before delivery.
It integrates primary power components, control, protection and auxiliary equipment inside one metal enclosure. It suits indoor and outdoor installation for power utilities, renewable energy plants and heavy industrial users.
The metal enclosed capacitor bank injects controllable capacitive reactive power into the grid to offset inductive reactive power from loads. Fixed banks stay continuously energized. Multi-step switched banks receive signals from the power factor controller, switching contactors stage by stage.
It stabilizes voltage, improves power factor, reduces line losses and mitigates harmonic issues with optional detuning or filter reactors. Comprehensive protection relays monitor current, voltage, unbalance and earth faults to guarantee safe operation.
We provide fully factory assembled and tested metal enclosed capacitor banks, complying with IEC, IEEE/ANSI, CSA international standards. Modular design separates incoming unit, power unit and control cubicle, easy for maintenance and future expansion.
The enclosure material options include corrosion-resistant aluminum, galvanized steel or stainless steel, with IP65 / NEMA 4X high protection grade for outdoor harsh environments. Complete protection suite covers overcurrent, earth fault, unbalance, over/under voltage and arc fault mitigation.
All copper busbars are tinned hard drawn copper for reliable conductivity. We support customized capacity, voltage and seismic/wind resistance requirements for mining, chemical, solar and wind farm projects.
| Category | Item | Parameter |
|---|---|---|
| General | Rated Voltage | Up to 12 kV |
| Maximum Output Capacity | Up to 30 Mvar | |
| Frequency | 50 Hz / 60 Hz | |
| Installation Location | Indoor / Outdoor | |
| Ambient Temperature | -10 ℃ ~ +50 ℃ | |
| Altitude | <1000 m | |
| Humidity | Max 90% RH, non-condensing | |
| Insulation Level | Up to 200 kV BIL | |
| Short Circuit Withstand Current | Up to 50 kA for 1 s | |
| Bank Configuration | Fixed, single-step or multi-step switched | |
| Interlock | Optional mechanical / solenoid interlock | |
| Arc Fault Protection | Optional arc fault mitigation | |
| Busbar | Tinned hard drawn copper | |
| Applicable Standards | IEC, IEEE/ANSI, CSA | |
| Wind & Seismic Rating | ASCE 7-10 wind, IEEE 693 seismic standard | |
| Enclosure | Enclosure Material | Corrosion resistant AA aluminum, zinc-coated steel, stainless steel |
| Base Frame | Hot dipped galvanized steel | |
| Protection Class | IP65 / NEMA 4X | |
| Door Lock | 3-point lock handle, 1/4 turn blind lock | |
| Installation | Base fixed mounting | |
| Lifting Method | Forklift & crane lifting from base | |
| Cable Entry | Bottom entry, optional side entry | |
| Capacitor Unit | Phase Type | Single phase / Three phase |
| Fusing | Internal fused or unfused | |
| Discharge Resistor | Built-in | |
| Total Loss | <0.15 W/kvar (including discharge resistors) | |
| Dielectric | Polypropylene film | |
| Tank Material | Stainless steel | |
| Bushing | Grey porcelain (1/2/3 bushings) | |
| Reactor | Inrush Reactor | Single phase, air core |
| Detuning / Filter Reactor | Single / three phase, iron core or air core | |
| Contactor | Type | Vacuum contactor, transient-free optional |
| Phase | 3-phase | |
| Rated Current | 1250 A | |
| Isolator & Earth Switch | Type | Air-insulated |
| Phase | 3-phase | |
| Rated Current | 1250 A | |
| HRC Fuse | Rated Current | Up to 315 A |
| Short Time Withstand Current | Max 63 kA | |
| Power Factor Controller | Core | Microprocessor, harmonic immunity |
| Control Voltage | 100 VAC ~ 240 VAC | |
| PF Setting Range | 0.7 inductive ~ 0.7 capacitive |
Note: Higher or lower ratings are available upon customized request.
Power distribution utilities, solar farms, wind farms, mining, pulp & paper, chemical, petrochemical, cement and other heavy industrial power supply systems.
Yes. Arc fault mitigation system is an optional package for this capacitor bank. When internal arc faults occur, the system quickly detects the arc signal and triggers protection actions to limit arc energy and reduce hazards to on-site operators. We can provide arc flash calculation support and safety documentation to meet site electrical safety regulations for heavy industrial plants.
A detuning reactor is mainly used to detune the circuit away from harmonic resonance points and avoid harmonic amplification between the capacitor bank and grid.
A filter reactor works together with capacitors to form a tuned filter branch, which can actively absorb specific harmonic orders. Our engineers will analyze your on-site harmonic spectrum and recommend the proper reactor type and tuning scheme.
The modular design supports future expansion. If you reserve empty module compartments and control capacity during the initial order, you can add extra power stages later without replacing the whole cabinet. We can pre-reserve busbar interfaces and controller logic channels, and provide upgrade guidance and program adjustment service when you expand capacity.
A complete interlock logic is implemented for safety isolation. The isolator cannot be closed when the cabinet door is open; the cabinet door can only be opened after the earthing switch is closed. The capacitor built-in discharge resistors will drain residual voltage. The interlock system prevents mis-operation and accidental contact with live parts during inspection and maintenance.
Absolutely. We can carry out structural design and finite element calculation according to regional wind and seismic codes. The cabinet frame, base and fixing structure will be reinforced accordingly. We can provide structural calculation reports and supporting documents for wind farm owner review and approval.