• 5kVA-1000kVA Solar isolation transformers
5kVA-1000kVA Solar isolation transformers
discuss personally
Model
SG-200kVA
SG-100kVA
SG-1000kVA
Basic info
Brand ROCKWILL
Model NO. 5kVA-1000kVA Solar isolation transformers
Rated frequency 50/60Hz
Rated capacity 200kVA
Series SG
Product Detail

Product Overview

The transformer is the main component of various power supplies and electrical equipment, the transformer is composed of cylindrical windings and laminated iron cores, and the iron cores are stacked with new high-quality high-silicon silicon steel sheets and fully mitered joints. The company adopts advanced production technology, with imported Spanish winding machine and a full set of vacuum pressure impregnation equipment; The winding adopts the whole column winding method; Vacuum impregnation of the transformer to make the insulation grade of the transformer reach class F or H. The output and input voltages of the transformer can be designed according to customer needs.

Product features:

  • Scientific and reasonable design, the voltage change rate is controlled within 1~1.5%.

  • It is made of high-quality new silicon steel sheet, which can effectively reduce iron loss and improve efficiency.

  • It is made of high-quality wire rod with high temperature resistance, which minimizes its own loss and greatly improves the efficacy.

  • The use of H-class insulation, high temperature resistant insulation materials, improve the high voltage strength, insulation grade, and prolong the service life.

  • High efficiency design, up to more than 98%.

  • Patented design, beautiful, novel, high power density, small size, high space utilization.

  • The product chassis is divided into stainless steel and iron boxes, and there are inlet and outlet holes outside the box shell for the installation of power lines. If necessary, voltmeter, ammeter, temperature control alarm system, etc. can be added according to user requirements.

Technical data:

Product Advantages:

  • 100% full power.

  • Imported silicon steel sheet Low iron loss High magnetic induction strength.

  • LED display Clear and intuitive display.

  • Adopt high temperature resistant DM0.2 insulating paper Insulating sleeve 155°C.

  • Pure copper coil Wire two-layer insulating paint Low wire loss Not easy to oxidize.

  • The box has a built-in cooling fan,Intelligent control of temperature control meter .

  • The chassis is painted with the latest technology, and the rainproof design is IP65 certified.

Material description of transformer:

  • Iron core:Adopts new high-quality high-silicon silicon steel sheet, the main material is 0.35 thick H18, H14, H12, Z11 high-quality silicon steel sheet, we select the most suitable material according to customer requirements and use conditions, so that the transformer performance design to achieve the best. (The conventional material is a new high-quality silicon steel sheet).

  • The wire:Rod is made of PEW, UEW, EIW, SEIW, FEAI enameled wire and glass wire coated wire, and the temperature resistance level is F class (155 °C), H class (180 °C), HC class (200 °C), C class (220 °C). (The conventional temperature resistance level is H class 180°C).

  • Insulating material:High temperature resistant insulating paper is used as insulating material, which has multiple properties of high temperature insulation, flame retardant and moisture resistance.

  • Terminal block :The terminal block adopts the terminal block for small power, which is beautiful in appearance and has excellent voltage resistance, temperature resistance and flame retardant performance. The high power adopts high-quality copper bar.

  •  Iron feet:Mainly use CNC bending cold plate

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
What are the accident scenarios in a substation?
What are the accident scenarios in a substation?
Handling of Minor Action of Transformer Gas RelayImmediately check and record the protective relay action signals, and report to the dispatcher and station manager.Closely monitor the transformer’s voltage, current, temperature, oil level, oil color, sound, and cooler operation, and assign personnel to conduct an external inspection of the transformer.If significant abnormalities are found during the inspection, report to the dispatcher and take the faulty transformer offline. If no obviou
Leon
07/30/2025
Power System Voltage Level Classification
Power System Voltage Level Classification
What Is a Voltage Class?Definition of Voltage Class:Voltage classes (or voltage levels) refer to a set of standardized rated voltages used in power systems and electrical equipment. A rated voltage is the nominal voltage at which equipment is designed to operate under normal conditions; essentially, a voltage class defines the intended working voltage range for a system or device.Analogy to Consumer Appliances:Household appliances (e.g., refrigerators, TVs) operate at a nominal voltage—typ
Vziman
07/30/2025
What is the reason for conducting five impulse tests before commissioning a transformer?
What is the reason for conducting five impulse tests before commissioning a transformer?
Verification of Insulation IntegrityWhen a new or overhauled transformer is energized under open-circuit (no-load) conditions, switching surges—caused by operations such as opening or closing the no-load transformer circuit—can generate overvoltages. These reach 4.0–4.5 times the phase voltage if the neutral point is isolated or earthed through a Petersen coil, and up to 3.0 times the phase voltage when the neutral is solidly grounded. The full-voltage, no-load impact test deli
Rockwell
07/30/2025
Analysis of the Causes of Large - scale Failures of Surge Arresters in 10 kV Distribution Lines
Analysis of the Causes of Large - scale Failures of Surge Arresters in 10 kV Distribution Lines
1. IntroductionDuring power system operation, main equipment faces threats from internal and atmospheric overvoltages. Surge arresters, especially metal oxide arresters (MOAs) with excellent nonlinear volt - ampere characteristics, are key for protection due to their good performance, large current - carrying capacity, and strong pollution resistance. However, long - term exposure to power frequency voltages, along with component quality, manufacturing processes, and external environments, makes
Leon
07/30/2025
Key Points of Online Monitoring Technology for Zinc Oxide Surge Arresters
Key Points of Online Monitoring Technology for Zinc Oxide Surge Arresters
1 Architecture of the Online Monitoring System for Zinc Oxide Surge ArrestersThe online monitoring system for zinc oxide surge arresters comprises three layers: the station control layer, bay layer, and process layer.Station Control Layer: Includes a monitoring center, a Global Positioning System (GPS) clock, and a B - code clock source.Bay Layer: Consists of online monitoring Intelligent Electronic Devices (IEDs).Process Layer: Features monitoring terminals for Potential Transformers (PTs) and
Oliver Watts
07/30/2025
Improvement and Application of the Test Device for Surge Arrester Online Monitor
Improvement and Application of the Test Device for Surge Arrester Online Monitor
1 Significance of Surge Arrester Online Monitors1.1 Enhance Power System Safety, Reduce Lightning DamageDuring lightning strikes, surge arresters play a core role in discharging overvoltage. Online monitors ensure arrester stability, detect potential faults in real - time, and trigger alarms for timely intervention—effectively reducing lightning - induced damage to power equipment and systems, and maintaining stable operation.1.2 Real - Time Status Monitoring, Improve Maintenance Efficienc
Edwiin
07/30/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!