• 160kW 180kW 200kW 240kW 320KW GBT CCS1 CHAdeMO CCS2 Connector Double Gun Fast DC EV Charging Station
  • 160kW 180kW 200kW 240kW 320KW GBT CCS1 CHAdeMO CCS2 Connector Double Gun Fast DC EV Charging Station
  • 160kW 180kW 200kW 240kW 320KW GBT CCS1 CHAdeMO CCS2 Connector Double Gun Fast DC EV Charging Station
  • 160kW 180kW 200kW 240kW 320KW GBT CCS1 CHAdeMO CCS2 Connector Double Gun Fast DC EV Charging Station
  • 160kW 180kW 200kW 240kW 320KW GBT CCS1 CHAdeMO CCS2 Connector Double Gun Fast DC EV Charging Station
160kW 180kW 200kW 240kW 320KW GBT CCS1 CHAdeMO CCS2 Connector Double Gun Fast DC EV Charging Station
discuss personally
Model
WZ08-160kW-2EJ-20INGYNN
WZ08-160kW-2EU-20INGYNN
WZ08-160kW-2CE-20INGYNN
WZ08-160kW-2E-20INGYNN
WZ08-160kW-2C-20INGYNN
Basic info
Brand RW Energy
Model NO. 160kW 180kW 200kW 240kW 320KW GBT CCS1 CHAdeMO CCS2 Connector Double Gun Fast DC EV Charging Station
Rated Output Rating 160kW
Output Voltage DC 200-1000V
Power Conversion Efficiency ≥95%
Connector Options CCS2+CHAdeMO
Cable Length 5m
Input Voltage 380V
Series DC EV Chargers
Product Detail

Description:

This series of DC fast chargers offers 160kW, 180kW, 200kW, 240kW, and 320kW power options with GBT, CCS1, CHAdeMO, CCS2 connectors, supporting dual-gun simultaneous charging to meet the high-efficiency energy replenishment needs of global EVs. Compatible with domestic GB/T vehicles, European/American CCS models, and Japanese CHAdeMO standards, it enables plug-and-charge convenience for all major EV brands.

Key Features:

  • Full Power Range Coverage: Five power configurations from 160kW to 320kW, suitable for light buses, passenger cars, and electric trucks. The 320kW model charges vehicles from 10% to 80% in just 30 minutes.

  • Dual-Gun Parallel Charging: Two independent charging guns support simultaneous operation, with each gun delivering up to 320kW, significantly enhancing station throughput and reducing user wait times.

  • Universal Compatibility: Integrates four major charging standards (GBT/CCS1/CHAdeMO/CCS2), compatible with over 99% of global EVs, including Tesla, BYD, Volkswagen, Nissan, etc.

  • Intelligent Power Management: Dynamic power allocation system optimizes current distribution between guns, ensuring stable output even during simultaneous charging.

  • Efficient Cooling & Safety: Liquid-cooled thermal management with smart temperature control enables operation in -30°C to 55°C environments. Equipped with overvoltage/overcurrent protection, leakage monitoring, and fireproof design.

  • Flexible Deployment: Wall-mounted or floor-standing installation options, adaptable to highway rest areas, commercial parking lots, and logistics parks. Seamless integration with third-party management platforms.

Specifications:

Project  Technical Parameter
 Power

160kW/180kW/200kW

/240kW/320kW

 Model WZ08/09/10/11/12
Connector  GBT/CCS2/CHAdeMO/CCS1
Max Power 240kW
 Emergency Stop Button Yes
Communication Protocol OCPP1.6 
Input Voltage 380V(-25%,+25%)AC
Frequency、Output Voltage 50Hz、50V~1000VDC
Protection Grade IP54
Power distribution Average power distribution
Power factor >0.99
Peak efficiency 95.5%
 Overall efficiency 94%
auxiliary powersupply 12V
humidness <95%
Soft startup time 3 - 8S
Output voltage error <±0.5%
Output current error >30A ,<±1%;<30A ,<±0.3A
Voltage accuracy <0.5%
Steady flow accuracy <1%
 Voltage ripple <1%
 Current sharing <5%
 Load adjustment rate <1%
 Emc GB/T19826 - 2014:5.4
Starting mode Swipe card/small program scan code
Insulation resistance >10MΩ
 Withstand voltage AC2500V
 Display screen 7"touch screen
 Installation mode Floor
Operating temperature -35°C~+55°C
Charging gun length 5m/7m/8m
 Altitude <2000m 
Outer dimension WZ08:700mm600mm1900mm 
Harmonic distortion <5%

How to fast charge a car at a fast DC EV charging station with dual charging guns?

When two electric vehicles are connected to two charging guns of a charging pile, the charging pile establishes a communication connection with the Battery Management System (BMS) of each vehicle through the communication lines inside the charging guns. It confirms the vehicle's identity information, battery status (such as State of Charge, SOC, battery temperature, etc.), and charging requirements. The charging pile needs to dynamically allocate the total output power according to the actual charging needs of both vehicles. This is typically achieved through an internal power management system that decides how to distribute power based on each vehicle's charging request and the current state of the power grid. For example, if one vehicle has a lower battery capacity and the other has a higher battery capacity, the charging pile may prioritize providing a greater charging power to the vehicle with the lower battery capacity. Power conversion then takes place.

Know your supplier
RW Energy
Zhejiang Rockwell Energy Technology Co., Ltd. is an international enterprise specializing in the research, development and manufacturing of recloser controllers, power quality management, power monitoring systems and other high-end power equipment. In today's critical period of global energy transition and power system upgrading, the company has gathered a group of top talents in the fields of power engineering, automation control, software development, etc., who carry the enthusiasm and persistence for the power business, and are committed to overcoming the complex problems in the power system, and promoting the intelligent development of the power industry with innovative technology. Mission: To make global electricity smarter, more reliable and more efficient with innovative technology. Vision: To be the leader in global power intelligence.
Main Categories
High voltage/New energy/Tester
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
30000m²
占位
占位
Related Products
Related Knowledges
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
What are the common faults of low-voltage voltage transformers?
What are the common faults of low-voltage voltage transformers?
1. Open - Circuit Fault on the Secondary SideOpen - circuit in the secondary side is a typical fault of low - voltage voltage transformers, showing abnormal voltmeter readings (zero/fluctuation), faulty power meters, buzzing noises, and core overheating. When open - circuited, the secondary voltage spikes (no secondary current to balance the primary EMF), causing core saturation, flux distortion, and potential overheating/damage.Causes include loose terminals, poor contact, or human error. In lo
Oliver Watts
07/16/2025
A Quick Verification Method for Low-Voltage Current Transformers
A Quick Verification Method for Low-Voltage Current Transformers
1. Selection of Low - Voltage Current Transformer ConfigurationThere are many factors leading to wrong selection of low - voltage current transformers in civil construction projects. For example, common factors include design problems: the calculated coefficient designed for the load of electrical equipment is relatively large, or the transformation ratio of the current transformer is selected incorrectly. Such a series of reasons will affect the use of electrical equipment. Therefore, in the co
James
07/16/2025
A Quick Verification Method for Low-Voltage Current Transformers
A Quick Verification Method for Low-Voltage Current Transformers
To ensure safe operation of the power system, power equipment operation must be monitored/measured. General devices can’t connect to primary high - voltage equipment directly; instead, large primary currents are scaled down for current transformation, electrical isolation, and use by measurement/protection devices. For AC large - current measurement, conversion to a unified current eases secondary instrument use.Current transformers split into measurement - and protection - type, with accu
Oliver Watts
07/16/2025
Research on Low - Voltage Anti - DC Current Transformer and Detection Device
Research on Low - Voltage Anti - DC Current Transformer and Detection Device
1. Overview of Components and IssuesTA (low-voltage current transformer) and electric energy meters are key components of low-voltage electric energy metering. The load current of such meters is no less than 60A. Electric energy meters vary in type, model, and anti-DC performance, and are connected in series in the metering device. Due to the lack of anti-DC capability, they suffer from metering errors under DC component loads, usually caused by non-linear loads. With the increasing use of DC or
Dyson
07/16/2025
Anti - Theft Device for Low - Voltage Current Transformers
Anti - Theft Device for Low - Voltage Current Transformers
1. Innovation BackgroundWith the progress of society and economic development, the electricity demand of power users is expanding increasingly. Lawbreakers, aiming to save electricity costs and pursue high profits, gradually use high - tech methods to steal electricity, causing huge economic losses to power supply enterprises. Currently, popular electricity theft methods in the market include illegally opening the wiring cover of low - voltage transformers in electric energy metering boxes, alte
Dyson
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!