• 6/10kV Three - phase dry - type grounding/earthing transformer
  • 6/10kV Three - phase dry - type grounding/earthing transformer
6/10kV Three - phase dry - type grounding/earthing transformer
discuss personally
Model
DKSC-10/1000
DKSC-6/800
Basic info
Brand ROCKWILL
Model NO. 6/10kV Three - phase dry - type grounding/earthing transformer
Rated voltage 10kV
Rated frequency 50/60Hz
Rated capacity 1000kVA
Series DKSC
Product Detail

Description

Designed for grounding protection in medium-voltage power grids, the 6/10kV three-phase dry-type grounding transformer adopts epoxy resin vacuum casting thin-insulation technology. Both high and low-voltage windings are wound with copper foils, ensuring partial discharge values below 10pC. Thanks to the foil winding structure, it features large interlayer capacitance and linear initial voltage distribution, delivering outstanding lightning impulse withstand capability. The windings have consistent reactance heights and balanced ampere-turns, with near-zero axial short-circuit force, ensuring excellent short-circuit resistance.
With insulation classes F/H, the transformer operates safely at 155℃/180℃ long-term. Its core uses mineral oxide-insulated cold-rolled silicon steel sheets, achieving low no-load loss and noise. Moisture-proof, flame-retardant, and self-extinguishing, it suits urban distribution networks, industrial facilities, etc. Covering capacities up to 10,000kVA, it establishes a stable neutral grounding system for ≤35kV systems.

Feature

  •  High Lightning Impulse Withstand Capability:Due to the high - and low - voltage windings all being wound with copper strips (foils), the interlayer voltage is low, the capacitance is large, and the initial voltage distribution of the foil - type winding is close to linear. Therefore, its lightning impulse withstand capability is strong.
  •  High Short - Circuit Withstand Capability:Because the reactance heights of the high - and low - voltage windings are the same, there is no helix angle phenomenon, and the ampere - turn balance between the coils is achieved. The axial force on the high - and low - voltage windings caused by short - circuit is almost zero. Therefore, its short - circuit withstand capability is strong.
  • Good Anti - Cracking Performance:The dry - type transformer adopts the epoxy resin “thin insulation (1 - 3mm) technology”, which meets the requirements of occasions with low temperature, high temperature, and a large temperature variation range, and meets the anti - cracking requirements after long - term operation. It solves the cracking problem that is difficult to solve with the “thick insulation (6mm) technology”, providing reliable technical guarantee for dry - type transformers.
  • Strong Overload Capacity:If the load losses of transformers with the same capacity are equal, the area of the copper foil will be increased correspondingly compared with the copper conductor. After the volume is increased, the dosage of the filling resin is increased correspondingly. Therefore, the heat capacity of the winding is large, and the short - term overload capacity of the transformer is strong.
  • Good Flame - Retardant Performance:The epoxy resin vacuum casting process is adopted without environmental pollution, which is beneficial to environmental protection. The transformer has the characteristics of maintenance - free, moisture - proof, resistance to damp - heat, flame - retardant, and self - extinguishing, and is suitable for various environments and harsh conditions.
  • Low Loss and Low Noise:The iron core usually adopts high - quality cold - rolled silicon steel sheets insulated with mineral oxides. Through advanced processing technology, the loss level and no - load current are reduced to the minimum, and a very low noise level is achieved. At the same time, the assembled iron core is coated with class F resin paint on its surface to prevent dust, corrosion, smoke, and rust.
  •  High Temperature Resistance Grade:The epoxy resin dry - type transformer belongs to class F or class H insulation, and can operate safely at a high temperature of 155℃ or 180℃ for a long time. With the same capacity, it has a small volume and light weight, which can save installation costs, etc.
  •  Relevant Technical Specifications:Capacity ≤ 10000kVA; Voltage ≤ 35kV;  Insulation grade: class F or H

Main technical parameter

Outline Dimensions Diagram

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)Under the action of an electric field, in an insulation system, discharge occurs only in some regions and does not penetrate between the conductors with the applied voltage. This phenomenon is called partial discharge. If partial discharge occurs near a conductor surrounded by gas, it can also be called corona.Partial discharge can occur not only at the edge of a conductor but also on the surface or inside an insulator. The discharge occurring on the su
Leon
07/19/2025
What types of FACTS controllers are there?
What types of FACTS controllers are there?
According to the type of connection FACTS Controller with the power system, it is classified as;Series Connected ControllerShunt Connected ControllerCombined Series-Series ControllerCombined Shunt-Series ControllerSeries-Connected ControllersSeries controllers introduce a voltage in series with the line voltage, typically using capacitive or inductive impedance devices. Their primary function is to supply or absorb variable reactive power as needed.When a transmission line is heavily loaded, the
Edwiin
07/19/2025
What are FACTS and related technologies?
What are FACTS and related technologies?
FACTS (Flexible Alternating Current Transmission System) refers to a power electronics-based system that uses static devices to enhance the power transfer capability and controllability of AC transmission networks.These power electronic devices are integrated into conventional AC grids to boost key performance metrics, including:Power transfer capacity of transmission linesVoltage stability and transient stabilityVoltage regulation precisionSystem reliabilityThermal limits of transmission infras
Edwiin
07/19/2025
What are the differences between HVAC and HVDC?
What are the differences between HVAC and HVDC?
Difference Between HVAC and HVDCElectricity generated in power plants is transmitted over long distances to electrical substations, which then distribute it to consumers. The voltage used for long-distance power transmission is extremely high, and we will explore the reasons for this high voltage later. Additionally, the transmitted power can be in either alternating current (AC) or direct current (DC) form. Therefore, power can be transmitted using either HVAC (High Voltage Alternating Current)
Edwiin
07/19/2025
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?Electricity travels long distances before reaching consumers. Power plants, often remote, supply electricity through hundreds of miles and multiple substations. High-voltage transmission reduces line losses, with both AC and DC used. Though AC is familiar via utility poles and home outlets, HVDC offers unique advantages in power transmission.The goal of power transmission is to minimize losses and costs. While both face influencing factors, HVDC has more
Edwiin
07/19/2025
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Neutral - Point Grounding Modes and Protection of Transformers in Power GridsFor systems ranging from 110 kV to 500 kV, an effective grounding method shall be adopted. Specifically, under all operating conditions, the ratio of zero - sequence reactance to positive - sequence reactance X0/X1 of the system should be a positive value and not exceed 3. Meanwhile, the ratio of zero - sequence resistance to positive - sequence reactance R0/X1should also be a positive value and not exceed 1.In 330 kV a
Leon
07/19/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!