Interruptor specialis pro turbine eolica 40.5kV

  • 40.5kV wind power special load switch

Attributa principalia

Marca Wone
Numerus Modeli Interruptor specialis pro turbine eolica 40.5kV
Votum nominatum 40.5kV
currus electricus nominatus 1250A
Frequenta nominata 50(Hz)
currentus interruptus 50kA
Series NFZ77

Descriptiones productorum a fornitori

Descriptio

Describtiō:

Principālēs cōnsistit ex armātūrā, interruptōre disiunctiōnis (in interruptōre disiunctiōnis installātur limitātor cursūs fusiōnis), vācuō interruptōre, interruptōre terrae, mēchanismō operatiōnis spīrae, etc. Id aptum est ad trīplex commūnicātiōnem AC 35kV, 50Hz, aut cum completīs ēquipamentīs dīstributtivīs, switchgear annulāris, combinātō substationis, etc.

Industriae applicatiōnēs:

Largē utitur in generatiōne ventī, constructiōne et renovatiōne rete urbānae, industriīs et minibus, aedificiīs altīs et facilitātibus publicīs, etc., et potest uti pro dīstributtione, contrōle et protectiōne unitātum dīstributtivārum annulārium aut ēquipamentīs terminālibus.

Characteristīcae:

  • Vacuō interruptōre ultrāmoderō.

  • Structūra compacta et parvus magnitūdō. 

  • Longa vita electrica et frequentia operatiōnis.

  • Fōrta claudendi et disiungendi capacitas, sēcūra et fidēlis.

  • Facile operāri et conservāri.

  • Flexibilis mēchanismus spīrae actūs

  • Utatur motōre electricō (cum manuālī) spīrae energiae condendae.

  • Habet capacitem controlandī remotē.

  • Sunt duae methodī: electromagnetica synthēsis et interpretātiō.

  • Potest equipāri cum functione protectionis supercurrentis.

  • Potens all-in-one characteristīcae

  • Integrat circuitōrum interruptōrem, disiunctōrem et interruptōrem terrae.

  • Fractūrae disiunctiōnis visibilia et cultrōs terrae cum capacitate claudendi.

  • Fidēles interclusiōnes mechanicās adversus errōres.

  • Capacitas disiungendi currēntiam nominālam (NFZR77-40.5D/T63-31.5 disiungibilis currēntiam short-circuit) et praeventiōnem ab exitū phase equipmentī.

Parametri technici:

image.png

image.png

Monstrātiō productī:

image.png


Monstrātiō productī:

20140829094947.jpg


Cūr nōs eligere:

  • Habēmus teamam servitium professionalēm

  • Habēmus bonam post venditam

  • Possumus qualitātem nostrōrum productōrum garantīre

Quid est interruptor oneris ventī?

Interruptor oneris ventī est dispositivum commutandi specializātum utendum in systematibus generantibus ventī. Principaliter utitur ad contrōlandum et protegendum lineās connexiōnis inter turbines ventī et reticulum electricum. Interruptor potest connectere et disiungere certam currēntiam oneris sub conditiōnibus normalibus et potest celeriter secāre circuitum quando occurrunt casūs taliās sicut superōnus aut short-circuits, sicque protegens equipmentum generantem ventī et reticulum electrum.

Principium Operatiōnis:

Cum turbine ventī generat electricitatem normaliter et suppeditat ad reticulum, interruptor oneris ventī est in positurā clausā, permittens currēntiam fluere per systemam contactuum inter generator et reticulum. Cum opus sit maintenance aut inspectiō turbine ventī, aut cum occurrit casus in reticulo (taliās sicut superōnus aut short-circuit), mēchanismus operativus agit contactus separāre. Hoc tempore, systema arc extinguendi activatur, celeriter extinguens arcum generatum per separationem contactuum, sicque interrompendo circuitum et providendo protectiōnem pro systemate electricō. Postquam casus solvit, interruptor oneris ventī potest reclosari ad reconstituendum connectionem inter turbine ventī et reticulum.



Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 65666m²m² Numerus omnium laborantium: 300+ Summa Annua Exportatio (USD): 50000000
Locus Operis: 65666m²m²
Numerus omnium laborantium: 300+
Summa Annua Exportatio (USD): 50000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: cable et filum/Energia nova/Instrumenta inspectionis/apparatus electrum altum voltus/Aedificii electritas Apparatus electricus/Apparatus electri bassa tensione/Instrumenta et mensurae/Instrumenta productiva/aestus apparatus/Ferramentae electricitatis
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum