• 550kV HV Gas Insulated Switchgear (GIS)
550kV HV Gas Insulated Switchgear (GIS)
discuss personally
Model
ZF27-550/6300-63
Basic info
Brand ROCKWILL
Model NO. 550KV GIS Gas Insulated Switchgear (GIS)
Rated voltage 550kV
Rated normal current 6300A
Series ZF27
Product Detail

Description:


The ZF27 - 550, an independently developed 550KV - level Gas Insulated Switchgear (GIS), boasts technical parameters at the international leading edge. Tailored for 550KV power systems, it enables seamless control, measurement, and protection. Comprising key components like circuit breakers, disconnectors, earthing switches, quick earthing switches, current transformers, busbars, and air - insulated bushings for power inlets and outlets, other components are enclosed in an earthed shell with SF6 gas serving as both arc - extinguishing and insulating medium. It can be flexibly configured into various connection modes per user needs.


Main Features:


  • The circuit breaker features a single - fracture arcing chamber with a simple, rational structure and advanced technology.

  • It offers robust breaking capabilities, an extended electrical contact lifespan, and a long service life.

  • The circuit breaker unit can be installed on - site without opening the chamber and filled with SF6 gas directly, preventing dust and foreign matter ingress.

  • The innovative hydraulic operating mechanism has minimal external piping, reducing the likelihood of oil leakage.

  • During operation, the hydraulic operating mechanism is automatically regulated by the pressure switch, maintaining a constant rated oil pressure regardless of ambient temperature. Its relief valve safeguards against overpressure risks.

  • In case of pressure loss, the hydraulic operating mechanism prevents slow tripping during pressure restoration.

  • The closing resistance of the product can be optionally installed or removed based on user requirements.

Technical Parameters:

1718679970148.png

What are the technical parameters of gas-insulated Switchgear?

Rated Voltage:

  • Common rated voltage levels include 72.5kV, 126kV, 252kV, 363kV, and 550kV. The rated voltage determines the maximum operating voltage that the equipment can withstand and is a crucial factor in the design and selection of GIS (Gas-Insulated Switchgear) equipment. It must match the voltage level of the power system to ensure that the equipment operates safely and reliably under both normal and fault conditions.

Rated Current:

  • The rated current ranges from a few hundred amperes to several thousand amperes, such as 1250A, 2000A, 3150A, 4000A, etc. The rated current indicates the maximum current that the equipment can carry continuously without damage. When selecting the equipment, it is necessary to consider a certain margin based on the actual load conditions to ensure that the equipment does not fail due to overload during normal operation and can also meet future load growth requirements.

Rated Short-Circuit Breaking Capacity:

  • Typically, the rated short-circuit breaking capacity ranges from 31.5kA to 63kA or even higher. This parameter measures the equipment's ability to interrupt short-circuit currents. When a short-circuit fault occurs in the power system, the short-circuit current increases dramatically. The GIS equipment must be able to quickly and reliably interrupt the short-circuit current to prevent the fault from escalating. The rated short-circuit breaking capacity must be greater than the maximum possible short-circuit current in the system to ensure the safety performance of the equipment during a short-circuit condition.

SF₆ Gas Pressure:

  • The rated pressure of SF₆ gas in the equipment is generally between 0.3MPa and 0.7MPa. The actual operating pressure may be adjusted according to the specific requirements of the equipment and environmental factors such as temperature. During operation, it is necessary to monitor and control parameters such as the pressure, humidity, and purity of the SF₆ gas to ensure they remain within specified limits. This ensures the insulation and arc-quenching performance of the equipment.



Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!