Model
WZ08-160kW-2EJ-20INGYNN
WZ08-160kW-2EU-20INGYNN
WZ08-160kW-2CE-20INGYNN
WZ08-160kW-2E-20INGYNN
WZ08-160kW-2C-20INGYNN
Basic info
Brand RW Energy
Model NO. 160kW 180kW 200kW 240kW 320KW GBT CCS1 CHAdeMO CCS2 Connector Double Gun Fast DC EV Charging Station
Rated Output Rating 160kW
Output Voltage DC 200-1000V
Power Conversion Efficiency ≥95%
Connector Options CCS2+CHAdeMO
Cable Length 5m
Input Voltage 380V
Series DC EV Chargers
Product Detail

Description:

This series of DC fast chargers offers 160kW, 180kW, 200kW, 240kW, and 320kW power options with GBT, CCS1, CHAdeMO, CCS2 connectors, supporting dual-gun simultaneous charging to meet the high-efficiency energy replenishment needs of global EVs. Compatible with domestic GB/T vehicles, European/American CCS models, and Japanese CHAdeMO standards, it enables plug-and-charge convenience for all major EV brands.

Key Features:

  • Full Power Range Coverage: Five power configurations from 160kW to 320kW, suitable for light buses, passenger cars, and electric trucks. The 320kW model charges vehicles from 10% to 80% in just 30 minutes.

  • Dual-Gun Parallel Charging: Two independent charging guns support simultaneous operation, with each gun delivering up to 320kW, significantly enhancing station throughput and reducing user wait times.

  • Universal Compatibility: Integrates four major charging standards (GBT/CCS1/CHAdeMO/CCS2), compatible with over 99% of global EVs, including Tesla, BYD, Volkswagen, Nissan, etc.

  • Intelligent Power Management: Dynamic power allocation system optimizes current distribution between guns, ensuring stable output even during simultaneous charging.

  • Efficient Cooling & Safety: Liquid-cooled thermal management with smart temperature control enables operation in -30°C to 55°C environments. Equipped with overvoltage/overcurrent protection, leakage monitoring, and fireproof design.

  • Flexible Deployment: Wall-mounted or floor-standing installation options, adaptable to highway rest areas, commercial parking lots, and logistics parks. Seamless integration with third-party management platforms.

Specifications:

Project  Technical Parameter
 Power

160kW/180kW/200kW

/240kW/320kW

 Model WZ08/09/10/11/12
Connector  GBT/CCS2/CHAdeMO/CCS1
Max Power 240kW
 Emergency Stop Button Yes
Communication Protocol OCPP1.6 
Input Voltage 380V(-25%,+25%)AC
Frequency、Output Voltage 50Hz、50V~1000VDC
Protection Grade IP54
Power distribution Average power distribution
Power factor >0.99
Peak efficiency 95.5%
 Overall efficiency 94%
auxiliary powersupply 12V
humidness <95%
Soft startup time 3 - 8S
Output voltage error <±0.5%
Output current error >30A ,<±1%;<30A ,<±0.3A
Voltage accuracy <0.5%
Steady flow accuracy <1%
 Voltage ripple <1%
 Current sharing <5%
 Load adjustment rate <1%
 Emc GB/T19826 - 2014:5.4
Starting mode Swipe card/small program scan code
Insulation resistance >10MΩ
 Withstand voltage AC2500V
 Display screen 7"touch screen
 Installation mode Floor
Operating temperature -35°C~+55°C
Charging gun length 5m/7m/8m
 Altitude <2000m 
Outer dimension WZ08:700mm600mm1900mm 
Harmonic distortion <5%

How to fast charge a car at a fast DC EV charging station with dual charging guns?

When two electric vehicles are connected to two charging guns of a charging pile, the charging pile establishes a communication connection with the Battery Management System (BMS) of each vehicle through the communication lines inside the charging guns. It confirms the vehicle's identity information, battery status (such as State of Charge, SOC, battery temperature, etc.), and charging requirements. The charging pile needs to dynamically allocate the total output power according to the actual charging needs of both vehicles. This is typically achieved through an internal power management system that decides how to distribute power based on each vehicle's charging request and the current state of the power grid. For example, if one vehicle has a lower battery capacity and the other has a higher battery capacity, the charging pile may prioritize providing a greater charging power to the vehicle with the lower battery capacity. Power conversion then takes place.

Know your supplier
RW Energy
Zhejiang Rockwell Energy Technology Co., Ltd. is an international enterprise specializing in the research, development and manufacturing of recloser controllers, power quality management, power monitoring systems and other high-end power equipment. In today's critical period of global energy transition and power system upgrading, the company has gathered a group of top talents in the fields of power engineering, automation control, software development, etc., who carry the enthusiasm and persistence for the power business, and are committed to overcoming the complex problems in the power system, and promoting the intelligent development of the power industry with innovative technology. Mission: To make global electricity smarter, more reliable and more efficient with innovative technology. Vision: To be the leader in global power intelligence.
Main Categories
High voltage/New energy/Tester
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
30000m²
占位
占位
Related Products
Related Knowledges
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)Under the action of an electric field, in an insulation system, discharge occurs only in some regions and does not penetrate between the conductors with the applied voltage. This phenomenon is called partial discharge. If partial discharge occurs near a conductor surrounded by gas, it can also be called corona.Partial discharge can occur not only at the edge of a conductor but also on the surface or inside an insulator. The discharge occurring on the su
Leon
07/19/2025
What types of FACTS controllers are there?
What types of FACTS controllers are there?
According to the type of connection FACTS Controller with the power system, it is classified as;Series Connected ControllerShunt Connected ControllerCombined Series-Series ControllerCombined Shunt-Series ControllerSeries-Connected ControllersSeries controllers introduce a voltage in series with the line voltage, typically using capacitive or inductive impedance devices. Their primary function is to supply or absorb variable reactive power as needed.When a transmission line is heavily loaded, the
Edwiin
07/19/2025
What are FACTS and related technologies?
What are FACTS and related technologies?
FACTS (Flexible Alternating Current Transmission System) refers to a power electronics-based system that uses static devices to enhance the power transfer capability and controllability of AC transmission networks.These power electronic devices are integrated into conventional AC grids to boost key performance metrics, including:Power transfer capacity of transmission linesVoltage stability and transient stabilityVoltage regulation precisionSystem reliabilityThermal limits of transmission infras
Edwiin
07/19/2025
What are the differences between HVAC and HVDC?
What are the differences between HVAC and HVDC?
Difference Between HVAC and HVDCElectricity generated in power plants is transmitted over long distances to electrical substations, which then distribute it to consumers. The voltage used for long-distance power transmission is extremely high, and we will explore the reasons for this high voltage later. Additionally, the transmitted power can be in either alternating current (AC) or direct current (DC) form. Therefore, power can be transmitted using either HVAC (High Voltage Alternating Current)
Edwiin
07/19/2025
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?Electricity travels long distances before reaching consumers. Power plants, often remote, supply electricity through hundreds of miles and multiple substations. High-voltage transmission reduces line losses, with both AC and DC used. Though AC is familiar via utility poles and home outlets, HVDC offers unique advantages in power transmission.The goal of power transmission is to minimize losses and costs. While both face influencing factors, HVDC has more
Edwiin
07/19/2025
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Neutral - Point Grounding Modes and Protection of Transformers in Power GridsFor systems ranging from 110 kV to 500 kV, an effective grounding method shall be adopted. Specifically, under all operating conditions, the ratio of zero - sequence reactance to positive - sequence reactance X0/X1 of the system should be a positive value and not exceed 3. Meanwhile, the ratio of zero - sequence resistance to positive - sequence reactance R0/X1should also be a positive value and not exceed 1.In 330 kV a