• 2.4KWh-10.24KWh Rack type energy storage battery(Industrial&Commercial energy storage)
  • 2.4KWh-10.24KWh Rack type energy storage battery(Industrial&Commercial energy storage)
2.4KWh-10.24KWh Rack type energy storage battery(Industrial&Commercial energy storage)
$9828.00
Model
C48200
C48200
C48200
C48200
C48100
C48100
C48100
C48100
C4850
C4850
C4850
C4850
Basic info
Brand POWERTECH
Model NO. Rack type energy storage battery
Energy storage capacity 10.24kWh
Cell quality Class A
Series Industrial&Commercial energy storage
Product Detail

DCK-en.png                                    

Peculiarity

  • High energy density.

  • Equipped with BMS battery management system, longer cycle life.

  • Beautiful appearance; Standard rack specifications, free combination, easy installation.

  • The panel integrates a variety of interfaces, supports multiple protocols, and ADAPTS to most photovoltaic inverters and energy storage converters.

  • Can be customized adjustment management battery charging and discharging strategy.

  • Modular design, easy maintenance.

Technical parameter

image.png

image.png

Note:

  • The A-class cell can charge and discharge 6000 times, and the B-class cell can charge and discharge 3000 times, and the default discharge ratio is 0.5C.

  •  Class A cell warranty 60 months, Class B cell warranty 30 months. 

What are the characteristics of rack-mounted energy storage batteries?

  • High integration:All components (such as battery modules, battery management system (BMS), inverter, energy management system (EMS), etc.) are integrated in one or more standard racks, which is convenient for transportation and on-site installation.The racks usually follow certain standard sizes, such as the standard server cabinet with a width of 19 inches.

  • Modular design:The rack-mounted energy storage battery allows users to add or remove specific modules as needed to expand or reduce the capacity of the energy storage system.The energy storage units in each rack can operate independently or be combined into a larger energy storage system in parallel or in series.

  • Standardized interfaces:The rack-mounted design usually adopts standardized interfaces, making components of different brands or models interchangeable or compatible, reducing the difficulty of system integration.

  • Easy installation and maintenance:The rack-mounted design makes the installation of the energy storage system very simple. Only the rack needs to be placed in an appropriate position and necessary electrical connections are made.During maintenance, each module can be easily accessed for inspection or replacement.

  • High space utilization:The design of standard racks can maximize space utilization, enabling the energy storage system to achieve a high energy storage density in a limited space.

  • Remote monitoring and management:The rack-mounted energy storage system usually integrates remote monitoring and management functions, and the system can be monitored and controlled in real time through the Internet or a dedicated network.This characteristic is very important for energy storage applications that require remote operation and maintenance.

  • Environmental adaptability:The rack-mounted design can integrate environmental conditioning equipment such as temperature control and humidity control to ensure that the battery operates under optimal working conditions.The rack itself can also be designed with characteristics such as dustproof and waterproof to improve the environmental adaptability of the system.

Know your supplier
POWERTECH
We are an electrical company that manufactures and sells high and low voltage electrical products.
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$120000000
Professional Experience
7 years
Workplace
580000m²
占位
占位
Related Products
Related Knowledges
Why are the ground fault point and the accident point not at the same location?
Why are the ground fault point and the accident point not at the same location?
Fault Transfer VoltageIn low - voltage distribution systems, there is a type of personal electric shock accident where the accident occurrence point and the system fault point are not at the same location. This kind of accident occurs because after a ground fault happens elsewhere, the generated fault voltage is conducted to the metal casings of other equipment through the PE wire or PEN wire. When the fault voltage on the metal casing of the equipment is higher than the human - body safe voltag
Leon
07/18/2025
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!