| Brand | ROCKWILL | 
| Numero sa Modelo | 27kV Outdoor High - Voltage Vacuum recloser | 
| Naka nga boltahang rated | 27kV | 
| Rated Current | 800A | 
| Rated na nga kusog sa pag-abli sa short circuit | 20kA | 
| Mga pasabot sa tiyak nga higayon nga pagtahan sa kusog nga pataas | 70kV/min | 
| Rated Lightning Impulse Withstand Voltage | 150kV | 
| Manual na pagkonekta | Yes | 
| Mekanikal na kandado | No | 
| Serye | RCW | 
Deskripsyon:
Ang serye RCW sa automatic circuit reclosers gihimo alang sa paggamit sa overhead distribution lines ug distribution substations. Sila kompatibel sa power systems nga nagoperasyon sa 50/60Hz, nakakatabang sa voltage classes gikan sa 11kV hangtod sa 38kV. Ug may rated current capacity hangtod sa 1250A, ang mga reclosers niini nagsama sa daghang mga function sama sa control, protection, measurement, communication, fault detection, ug real-time monitoring sa closing ug opening operations. Gisusunod sa integration terminal, current transformer, permanent magnetic actuator, ug dedicated recloser controller, ang serye RCW sa vacuum reclosers maghatag og comprehensive solution para sa power distribution network management.
Mga Puna:
Flexible Current Ratings: Optional ratings within the rated current range to suit diverse application needs.
Customizable Protection: A variety of optional relay protection and logic schemes for users to choose from, ensuring adaptability to different system requirements.
Versatile Communication: Optional communication protocols and I/O ports available, enabling seamless integration with various monitoring and control systems.
User - Friendly Software: Equipped with PC software that supports controller testing, setup, programming, and updates, simplifying operation and maintenance.
Mga Parameter:


Mga External dimensions:

Mga Environmental requirement:

Unsa ang mga key points para sa selection sa outdoor vacuum reclosers?
System Parameter Matching: Choose a recloser that matches the rated voltage, rated current, and short-circuit current levels of the power system. Ensure that the rated voltage of the recloser is equal to or higher than the system voltage, the rated current meets the requirements of the line load current, and the rated short-circuit breaking and making currents are greater than the maximum possible short-circuit current in the system.
Reclosing Performance Requirements: Consider the specific requirements of the power system for the reclosing function, such as the number of reclosures, reclosing time intervals, and reclosing success rate. Based on different application scenarios and power supply reliability requirements, select a recloser with appropriate reclosing performance. For example, for critical power supply lines, a recloser with a higher number of reclosures and flexible reclosing time intervals may be required.
Type of Operating Mechanism: Choose an appropriate operating mechanism based on actual needs. Spring-operated mechanisms are suitable for outdoor environments where high reliability is required and maintenance conditions are relatively poor. Permanent magnet-operated mechanisms are better suited for applications requiring high action speed and frequent operations.
Environmental Adaptability: Given the harsh conditions of outdoor environments, consider the environmental adaptability of the recloser. This includes weather resistance, pollution resistance, and water and dustproof performance. Selecting a recloser with good environmental adaptability ensures stable performance during long-term outdoor operation.
Brand and Quality: Choose well-known brands and high-quality recloser products. These products have strict quality control systems in design, manufacturing, and testing, ensuring the performance and reliability of the product. Additionally, good after-sales service is an important factor to consider when choosing a brand, as it ensures timely resolution of issues that may arise during equipment operation.