• 12kV Indoor High Voltage Vacuum Circuit Breaker
  • 12kV Indoor High Voltage Vacuum Circuit Breaker
  • 12kV Indoor High Voltage Vacuum Circuit Breaker
12kV Indoor High Voltage Vacuum Circuit Breaker
discuss personally
Model
VDS4-12-3150
VDS4-12-2500
VDS4-12-2000
VDS4-12-1600
VDS4-12-1250
VDS4-12-630
Basic info
Brand ROCKWILL
Model NO. 12kV Indoor High Voltage Vacuum Circuit Breaker
Rated voltage 12kV
Rated normal current 3150A
Series VDS4
Product Detail

Product Introduction

The VDS4 series indoor high-voltage AC vacuum circuit breaker is designed for three-phase AC 50Hz power systems with a rated voltage ranging from 7.2 to 40.5kV. Widely applied in substations, power plants, industrial facilities, airports, and buildings, it excels at controlling and safeguarding electrical equipment. With its capabilities for frequent operations and rapid reclosing, it ensures reliable power management.

This breaker adheres to national standards, including GB/T 1984-2014 "High Voltage AC Circuit Breaker", JB/T 3855-2008 "High Voltage AC Vacuum Circuit Breaker", and DL/T 403-2000 "12kV~40.5kV Indoor AC High Voltage Vacuum Circuit Breaker Ordering Technical Requirements". It also complies with international regulations set by the International Electrotechnical Commission, such as IEC 62271-100, IEC 60694, and IEC 62271-1, guaranteeing quality and global compatibility.

Technical parameters

The following table details the key technical specifications of the product, comprehensively covering electrical performance, mechanical characteristics, and dimensional parameters to provide a clear reference for technical selection and application scenarios.

Features
The product offers multiple significant advantages, which can fully meet the diverse needs of industrial and power systems. Specifically included are:

  •  Excellent Electrical Performance of Fully Enclosed Pole

The main circuit of the VSV series vacuum circuit breaker adopts a fully enclosed structure, available in two types: insulated cylinder or solid pole.

  • Insulated Cylinder Structure:

The main electrical components are longitudinally installed in an epoxy resin cylinder cast via the APG process. This structure offers superior arc resistance, anti-aging properties, and high mechanical strength. It effectively shields the vacuum interrupter from external factors such as mechanical impacts and environmental pollution while enhancing the conductive circuit’s capability to withstand rated short-term (peak) withstand currents.

  • Sealed Pole Structure (P Series):

The miniaturized vacuum interrupter and other main circuit components are directly sealed in epoxy resin using advanced APG technology. This not only simplifies the pole assembly process and improves the reliability of the vacuum interrupter’s conductive circuit but also protects the interrupter’s outdoor surface from external mechanical forces and environmental influences.

  •  Corrosion-Resistant Mechanism with Advanced Design

Structural components undergo super anti-corrosion and anti-salt spray zinc-nickel alloy treatment.

Transmission parts are treated with high-hardness, wear-resistant, and corrosion-resistant nickel-phosphorus alloy.

International brand INA oil-free graphite bearings are used for transmission, ensuring high strength and excellent wear resistance.

  •  C2-Level Circuit Breaker Compliance

During capacitive current interruption, the breaker exhibits an extremely low probability of re-strike, fully meeting the requirements for C2-level circuit breakers.

  •  E2-Level Circuit Breaker Certification

The breaker has successfully passed all tests at the Shenyang High Voltage Electrical Appliance Research Institute and Xi’an High Voltage Electrical Appliance Research Institute testing centers. It complies with the E2-level standard, demonstrating:

  • 30 operations with full-rated short-circuit current for low-current breakers.

  • 20 operations with full-rated short-circuit current for high-current breakers.

 

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul
Vziman
08/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.