• 2000KVA 1600KVA 11KV 13.2KV 13.8KV  Pad-Mounted Transformers
2000KVA 1600KVA 11KV 13.2KV 13.8KV Pad-Mounted Transformers
discuss personally
Model
ZGS-11
Basic info
Brand ROCKWILL
Model NO. 2000KVA 1600KVA 11KV 13.2KV 13.8KV Pad-Mounted Transformers
Rated voltage 11kV
Series ZGS
Product Detail

Product Description
Rockwill's pad-mounted transformers are engineered for superior performance across a comprehensive power range from 75 kVA to 5000 kVA. Our units incorporate integrated high-voltage fuses and switches for complete circuit protection, featuring innovative elbow connector technology that enables safe live-line connections and maintenance operations using hot sticks. Designed for reliability, all transformers undergo rigorous testing and comply with leading industry standards including CSA, ANSI C57, DOE, and IEEE requirements.

The ZGS11-H(Z) series represents our next-generation combined transformer solution, offering an optimized compact design that delivers exceptional space efficiency without compromising performance. These units are specifically engineered for urban load center applications, providing enhanced power distribution efficiency and improved supply quality.

Key Features & Benefits

Advanced Safety System

  • Fully sealed, oil-filled construction with complete insulation
  • Integrated high-voltage protection with visible break switches
  • Tamper-resistant enclosure with secure locking mechanism

Network Flexibility

  • Dual-mode operation for both loop and radial feed configurations
  • Plug-and-play cable connection system
  • Compatible with SCADA and smart grid applications

Premium Performance

  • Ultra-low no-load and load losses (meets DOE 2016 efficiency standards)
  • Acoustic noise levels below NEMA standards
  • 150% overload capacity for emergency operation

Robust Construction

  • Military-grade corrosion protection (ASTM B117 salt spray tested)
  • -40°C to +50°C operational temperature range
  • Seismic-rated design (Zone 4 compliance)

Smart Ready Design

  • Built-in monitoring points for IoT integration
  • Optional remote temperature and load monitoring
  • Predictive maintenance capability

Typical Applications
• Urban distribution network upgrades and expansions
• High-density residential and commercial developments
• Critical infrastructure power systems (hospitals, data centers)
• Industrial parks and manufacturing facilities
• Renewable energy interconnection points

Parameters

Specification

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)Under the action of an electric field, in an insulation system, discharge occurs only in some regions and does not penetrate between the conductors with the applied voltage. This phenomenon is called partial discharge. If partial discharge occurs near a conductor surrounded by gas, it can also be called corona.Partial discharge can occur not only at the edge of a conductor but also on the surface or inside an insulator. The discharge occurring on the su
Leon
07/19/2025
What types of FACTS controllers are there?
What types of FACTS controllers are there?
According to the type of connection FACTS Controller with the power system, it is classified as;Series Connected ControllerShunt Connected ControllerCombined Series-Series ControllerCombined Shunt-Series ControllerSeries-Connected ControllersSeries controllers introduce a voltage in series with the line voltage, typically using capacitive or inductive impedance devices. Their primary function is to supply or absorb variable reactive power as needed.When a transmission line is heavily loaded, the
Edwiin
07/19/2025
What are FACTS and related technologies?
What are FACTS and related technologies?
FACTS (Flexible Alternating Current Transmission System) refers to a power electronics-based system that uses static devices to enhance the power transfer capability and controllability of AC transmission networks.These power electronic devices are integrated into conventional AC grids to boost key performance metrics, including:Power transfer capacity of transmission linesVoltage stability and transient stabilityVoltage regulation precisionSystem reliabilityThermal limits of transmission infras
Edwiin
07/19/2025
What are the differences between HVAC and HVDC?
What are the differences between HVAC and HVDC?
Difference Between HVAC and HVDCElectricity generated in power plants is transmitted over long distances to electrical substations, which then distribute it to consumers. The voltage used for long-distance power transmission is extremely high, and we will explore the reasons for this high voltage later. Additionally, the transmitted power can be in either alternating current (AC) or direct current (DC) form. Therefore, power can be transmitted using either HVAC (High Voltage Alternating Current)
Edwiin
07/19/2025
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?Electricity travels long distances before reaching consumers. Power plants, often remote, supply electricity through hundreds of miles and multiple substations. High-voltage transmission reduces line losses, with both AC and DC used. Though AC is familiar via utility poles and home outlets, HVDC offers unique advantages in power transmission.The goal of power transmission is to minimize losses and costs. While both face influencing factors, HVDC has more
Edwiin
07/19/2025
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Neutral - Point Grounding Modes and Protection of Transformers in Power GridsFor systems ranging from 110 kV to 500 kV, an effective grounding method shall be adopted. Specifically, under all operating conditions, the ratio of zero - sequence reactance to positive - sequence reactance X0/X1 of the system should be a positive value and not exceed 3. Meanwhile, the ratio of zero - sequence resistance to positive - sequence reactance R0/X1should also be a positive value and not exceed 1.In 330 kV a
Leon
07/19/2025
×