2000kVA 11kV 3 Phase Oil-immersed distribution transformer three-phase

  • 2000kVA 11kV 3 Phase Oil-immersed distribution transformer three-phase
  • 2000kVA 11kV 3 Phase Oil-immersed distribution transformer three-phase
  • 2000kVA 11kV 3 Phase Oil-immersed distribution transformer three-phase

Key attributes

Brand Vziman
Model NO. 2000KVA 11KV 3 Phase Oil-immersed distribution transformer three-phase
Rated voltage 11kV
Rated capacity 2000kVA
Series S
Description

Description:

Oil immersed transformer ,use our company special calculation and validation procedures to make sure theperformance of products. superior process equipment ,elaborate materialselecting and efficient manufacturing make the transformer have smallvolume,light weight,low loss,low partial discharge,low noise characteristics.

The product is stable,reliable,economic, environmental protection. lt can beapplied to many places such as power plants,transformer substation ,largeindustrial mining and petrochemical enterprise and so on.

Features:

  • Ultralow no-load loss

  • Energy saving and great power consuming efficiency

  • Copper coil winding, strong short circuit resistance ability

  • Dyn11 coil connection decrease the influences of harmonic wave

  • Fully sealed structure for maintenance free

  • Slow insulation aging & longer serving life

Parameters:

Oil-immersed distribution transformer three-phase

Model NO.

S-2000-11

Product classification

Distribution transformer

Rated capacity

2000kVA

Primary voltage

11kV

Secondary voltage

0.4kV

Number of phase

3

Number of winding

2

Rated frequency

50Hz

Tap changer

OCTC

Tap range

±2×2.5%

Vector group

Dyn11

Cooling system

ONAN

No-load loss

3250+10%

Load loss

16000+10%

Standard

IEC60076

Impedance

4.5±10%

Basic insulation level

75/28kv

Winding material ( H.V & L.V)

Copper

The way the bushing appears

Porcelain

Power frequency withstand voltage

——

Lightning impulse

——

The temperature rise—Winding

55k

The temperature rise --Top oil

65k

Tank color

——

Creepage distance

——

Environmental requirement

——

Transformer structure

——

External dimensions:

企业微信截图_17240295175304.png

Size

2026mm×1520mm×1925mm

Weight

2535KG


External dimensions:

Max. ambient temperature


Altitude



Product show:    

   

Yawei 160kVA 10kv Hot Selling Oil-Filled Three-Phase Distribution Transformer with UL


What are the benefits of oil-immersed transformers?

Excellent Cooling Performance:

  • High-Efficiency Heat Dissipation: Oil-immersed transformers use insulating oil as the cooling medium. The thermal conductivity of the oil is much higher than that of air, enabling it to more effectively transfer the heat inside the transformer to the outer surface of the oil tank and then dissipate it into the air through natural convection or forced cooling methods.

  • Uniform Cooling: The oil can evenly cover the iron core and windings, ensuring a more uniform temperature distribution in each part and reducing the risk of local overheating.

Good Insulation Performance:

  • High Insulation Strength: Insulating oil has excellent insulation properties and can provide a higher insulation strength than air, effectively preventing corona discharge and breakdown phenomena and enhancing the operational safety of the transformer.

  • Extended Lifespan: Good insulation performance can reduce the damage to insulation materials caused by electric field stress, thus prolonging the service life of the transformer.

High Reliability:

  • Stable Operation: Oil-immersed transformers can still operate stably under high-temperature, high-humidity, and harsh environmental conditions, making them suitable for various industrial and commercial application scenarios.

  • Multiple Protections: Modern oil-immersed transformers are equipped with multiple protective measures, such as gas relays, pressure release valves, and temperature sensors, which can detect and handle abnormal situations in a timely manner to improve safety.

Large Capacity and High-Voltage Applications:

  • Suitable for High Power: Oil-immersed transformers are suitable for application scenarios with large capacity and high voltage, such as main transformers in power systems and power supply for large industrial equipment.High Efficiency: High-quality winding materials and advanced manufacturing processes make oil-immersed transformers highly efficient, with low losses, energy-saving, and environmentally friendly.


Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 10000m² Total staff: 300 Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Related Products
Related Knowledges
  • Surge Arrester Structure and Electrical Testing Technology
    1.Critical Role of Surge Arresters in Power System Overvoltage ProtectionThe surge arrester serves as the primary line of defense against overvoltage in power systems. Its operational status directly determines the insulation safety of major equipment such as transformers, motors, and switchgear. Zinc Oxide Arresters (MOA), with their superior non-linear voltage-current characteristics, have become the most widely used protective devices in modern grids. Deeply understanding their internal confi
    04/11/2026
  • Comprehensive Comparison of Energy Efficiency Standards for Three-Phase Power Transformers
    1. OverviewThe national standard for "Minimum Allowable Values of Energy Efficiency and the Energy Efficiency Grades for Power Transformers" has undergone a major update. The new version, GB 20052-2024, was issued on April 29, 2024, and is scheduled for official implementation on February 1, 2025, at which time it will fully replace the current GB 20052-2020.This revision aligns with China's "Dual Carbon" goals, aiming to further enhance the energy efficiency of power equipment, phase out outdat
    04/10/2026
  • Technical Comparison of Recloser PMA vs SOM Mechanisms
    As devices that frequently break fault currents, recloser operating mechanisms must meet requirements for high consistency, extremely short opening and closing times, and tens of thousands of mechanical cycles. Traditional spring-operated mechanisms (SOM) achieve operation through mechanical energy storage and complex linkage systems, whereas permanent magnetic actuators (PMA) introduce direct electromagnetic drive and magnetic latching. As engineers with 29 years of experience, we know that mec
    04/08/2026
  • 110kV Transformer Partial Discharge Ultrasonic Localization Technology
    Importance of Partial Discharge Localization in 110kV Live Line TestingPartial discharge (PD) serves as a critical early warning sign of insulation deterioration within 110kV transformers. If left undetected, persistent discharge can cause irreversible carbonization of the oil-paper insulation, eventually leading to catastrophic dielectric failure. In the context of 110kV substation maintenance, ultrasonic localization has emerged as a primary diagnostic tool due to its high immunity to electrom
    04/08/2026
  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026