• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


2000kVA 11kV 3 Phase Oil-immersed distribution transformer three-phase

  • 2000kVA 11kV 3 Phase Oil-immersed distribution transformer three-phase
  • 2000kVA 11kV 3 Phase Oil-immersed distribution transformer three-phase
  • 2000kVA 11kV 3 Phase Oil-immersed distribution transformer three-phase

Key attributes

Brand Vziman
Model NO. 2000KVA 11KV 3 Phase Oil-immersed distribution transformer three-phase
Rated voltage 11kV
Rated capacity 2000kVA
Series S
Description

Description:

Oil immersed transformer ,use our company special calculation and validation procedures to make sure theperformance of products. superior process equipment ,elaborate materialselecting and efficient manufacturing make the transformer have smallvolume,light weight,low loss,low partial discharge,low noise characteristics.

The product is stable,reliable,economic, environmental protection. lt can beapplied to many places such as power plants,transformer substation ,largeindustrial mining and petrochemical enterprise and so on.

Features:

  • Ultralow no-load loss

  • Energy saving and great power consuming efficiency

  • Copper coil winding, strong short circuit resistance ability

  • Dyn11 coil connection decrease the influences of harmonic wave

  • Fully sealed structure for maintenance free

  • Slow insulation aging & longer serving life

Parameters:

Oil-immersed distribution transformer three-phase

Model NO.

S-2000-11

Product classification

Distribution transformer

Rated capacity

2000kVA

Primary voltage

11kV

Secondary voltage

0.4kV

Number of phase

3

Number of winding

2

Rated frequency

50Hz

Tap changer

OCTC

Tap range

±2×2.5%

Vector group

Dyn11

Cooling system

ONAN

No-load loss

3250+10%

Load loss

16000+10%

Standard

IEC60076

Impedance

4.5±10%

Basic insulation level

75/28kv

Winding material ( H.V & L.V)

Copper

The way the bushing appears

Porcelain

Power frequency withstand voltage

——

Lightning impulse

——

The temperature rise—Winding

55k

The temperature rise --Top oil

65k

Tank color

——

Creepage distance

——

Environmental requirement

——

Transformer structure

——

External dimensions:

企业微信截图_17240295175304.png

Size

2026mm×1520mm×1925mm

Weight

2535KG


External dimensions:

Max. ambient temperature


Altitude



Product show:    

   

Yawei 160kVA 10kv Hot Selling Oil-Filled Three-Phase Distribution Transformer with UL


What are the benefits of oil-immersed transformers?

Excellent Cooling Performance:

  • High-Efficiency Heat Dissipation: Oil-immersed transformers use insulating oil as the cooling medium. The thermal conductivity of the oil is much higher than that of air, enabling it to more effectively transfer the heat inside the transformer to the outer surface of the oil tank and then dissipate it into the air through natural convection or forced cooling methods.

  • Uniform Cooling: The oil can evenly cover the iron core and windings, ensuring a more uniform temperature distribution in each part and reducing the risk of local overheating.

Good Insulation Performance:

  • High Insulation Strength: Insulating oil has excellent insulation properties and can provide a higher insulation strength than air, effectively preventing corona discharge and breakdown phenomena and enhancing the operational safety of the transformer.

  • Extended Lifespan: Good insulation performance can reduce the damage to insulation materials caused by electric field stress, thus prolonging the service life of the transformer.

High Reliability:

  • Stable Operation: Oil-immersed transformers can still operate stably under high-temperature, high-humidity, and harsh environmental conditions, making them suitable for various industrial and commercial application scenarios.

  • Multiple Protections: Modern oil-immersed transformers are equipped with multiple protective measures, such as gas relays, pressure release valves, and temperature sensors, which can detect and handle abnormal situations in a timely manner to improve safety.

Large Capacity and High-Voltage Applications:

  • Suitable for High Power: Oil-immersed transformers are suitable for application scenarios with large capacity and high voltage, such as main transformers in power systems and power supply for large industrial equipment.High Efficiency: High-quality winding materials and advanced manufacturing processes make oil-immersed transformers highly efficient, with low losses, energy-saving, and environmentally friendly.


Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 10000m² Total staff: 300 Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Related Products
Related Knowledges
  • How has g3 technology changed the global climate?
    The Alternative to SF6 for High Voltage ApplicationsRemoving Greenhouse Gases from the GridNineteen of the warmest years on record have occurred since 2000, where greenhouse gases (GHGs) are at the root cause of climate change. Sulfur hexafluoride (SF₆), an insulating gas used in high-voltage switchgear, is estimated to contribute 23,500 times more than carbon dioxide (CO₂) to the greenhouse effect and can remain in the atmosphere for 3,200 years. Previously, Power Generation and Transmission ut
    05/09/2026
  • Difference Between Maintenance Earthing Switches and Fast Earthing Switches?
    Maintenance earthing switches and fast earthing switches (FES) are two types of switches with distinct characteristics.Maintenance Earthing SwitchesThese are typically configured alongside the disconnectors on both sides of a circuit breaker. Their sole purpose is to provide safety grounding on both sides of the circuit breaker during equipment maintenance.Fast Earthing Switches (FES)These are positioned on the line side of the outgoing disconnector in an outgoing circuit. They serve two primary
    05/08/2026
  • SiC MOSFET Solid State Circuit Breakers for Low Voltage Protection
    1. Core Principle SummaryIn simple terms, its core principle can be summarized as a three-step AC-DC-AC conversion, with the key step being to increase the frequency first, then transform the voltage.2. Working PrincipleRectification:First, the input line-frequency AC power (e.g., 50 Hz or 60 Hz) is rectified into DC power using power electronic devices (such as IGBTs). This step converts low-frequency AC into stable DC, preparing it for subsequent processing.High-Frequency Chopping (Inversion):
    05/03/2026
  • Solid-State Circuit Breakers Set to Revolutionize Circuit Protection
    Custom modules built with SiC MOSFETs minimize the impacts of short circuits and overloadsNearly every electrical engineer has wondered at some point whether it is possible to design a non-mechanical circuit breaker. There are plenty of reasons for this line of thought: would it not be better to use semiconductors to interrupt faults or handle overload conditions?However, deeper investigation inevitably reveals major obstacles. For one thing, the breakdown voltage of familiar power devices is ar
    05/03/2026
  • 2025 Complete Guide to Solar Cell Selection-Scenario Adaptation
    Solar Panel – Comprehensive Guide to Solar Cell SelectionA systematic selection reference for photovoltaic engineers and technicians, covering technical principles, key parameters, application scenarios and development trends.Data baseline: 2024–2025 industrial mass-production levels (CPIA data)1. The Role of Solar Cells in Photovoltaic SystemsMore than 90% of the conversion efficiency and power generation performance of PV modules are determined by solar cells. As the core semicondu
    05/03/2026
  • Technological Evolution of Silicon Carbide (SiC) Based DC Solid-State Circuit Breakers
    1. Introduction: Protection Challenges in the DC Distribution EraAs the global energy transition accelerates, DC microgrids, high-voltage DC (HVDC) power supplies for data centers, and large-scale energy storage systems have become critical components of power systems. However, DC systems lack a natural zero-crossing point and possess extremely low system impedance, leading to a rapid rate of rise of fault current (di/dt). Traditional mechanical circuit breakers, limited by millisecond-level ope
    04/25/2026
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.