• 15kV MV outdoor vacuum Auto Circuit recloser
  • 15kV MV outdoor vacuum Auto Circuit recloser
15kV MV outdoor vacuum Auto Circuit recloser
$7500.00
Model
RCW-F15G/630-16
RCW-F15G/400-12.5C
RCW-F15G/1250-25C
RCW-F15G/1250-25
RCW-F15G/800-20C
RCW-F15G/800-20
RCW-F15G/400-12.5
Basic info
Brand ROCKWILL
Model NO. 15kV MV outdoor vacuum Auto Circuit recloser
Rated voltage 15kV
Rated normal current 630A
Rated short circuit breaking current 16kV
Power frequency withstand voltage 45kV/min
Rated lightning impulse voltage 120kV
manual closing No
Series RCW
Product Detail

Description:

The RCW   series automatic circuit reclosers can use on overhead distribution lines as well as distribution substation applications for allvoltage classes 11kV up to 38kV at 50/60Hz power system.  and it’s rated current can reach 1250A.The RCW   series automatic circuit reclosers integrates the functions of control, protection, measurement, communication, fault detection, on-line monitoring of closing or opening.The RCW   series vacuum recloser is mainly combined with integration terminal, current transformer, permanent magnetic actuator and it’s recloser controller.

Features:

  • Optional grades available in rated current range

  • With optional relay protection and logic for user selection

  • With optional communication protocols and I/O ports for users to choose

  • PC software for controller testing, setup, programming, updates

Parameters:

Rated maximum voltage

15KV

Rated maximum current

400A

Rated frequency

50Hz

Rated short circuit breaking current

12.5KA

Rated peak value withstand current

31.5KA

Rated 1min power frequencywithstand voltageThree-phase Epoxy resin pole

45KV

Rated lightning impulse voltage(Three-phase Epoxy resin pole)

120KV

Operation sequence

C-0.5-CO-2-CO-5-CO(Magnetic actuator)

Mechanical life

n:30000(Magnetic actuator)

Power supply and operating voltage

110/220V( Customized)

Ratio of current transformer

400/1A( Customized)

Number of voltage sensorsThree-phase Epoxy resin pole

≤6

Opening time

≤30ms(Magnetic actuator)

Closing time

≤40ms(Magnetic actuator)

Minimum creepage distance

31level4mm/kv

Minimum distance between phases

360mm

Potential transformer

110/220V( Customized)

Cable length

6,8,12m( Customized)

Cable clampThree-phase Epoxy resin pole

4-hole NEMA

Lightning arrester

≤6

Mounting type

Single / double column

With optional relay protection& logics for user choice

Instantaneous over-current protection

Timing over-current protection

Negative sequence over-current protection

Directional over-current protection(*)

Over-voltage protection./Under voltage protection

Programable protection relay curves total 10 nos ANSI/IEC curves

Cold load pickup protection TCC +Hot line tag

Earth protection EF/SEF +Zone Sequence Co-ordination

More relay functions can be customized

With optional communication protocols & I/O port for user choice

RS-232 and RS-485 ports supporting

DNP3.0 communication protocol support(*)

Modbus communication protocol is optional(*)

IEC 60870-5-101 communication protocol support

IEC 60870-5-104 communication protocol support.(*)

The recloser can communicate through GPRS(Or GSM) modem with English or Specified language (*)

With optional functions for use

Rated currents, System phase current.

Rated voltages, System phase voltage& secondary low voltage power supply voltage. Frequency, 

power(kWh), reactive power(kV arh), power factor

With optional reclosing interval for user pre-program

Reclosing times setting support

Dead time setting support

With events recording function

SOE 10000 operations record

Fault record and normal operation record

Note: (*) mean should customized by manufacturer if needed

Environmental requirement:

Maximum temperature:

+40℃

Minimum temperature:

-30℃

Monthly average humidity

                          95%

Humidity:

                          90%

Above sea level:

2500m or higher

Ambient air not apparently polluted by corrosive and flammable gas, vapor

Product show:

企业微信截图_17104644186528.png


Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Analysis of the Integrated Application of Smart Meters and Meter Reading, Verification, and Billing Information Systems
Analysis of the Integrated Application of Smart Meters and Meter Reading, Verification, and Billing Information Systems
Meter reading, verification, and billing are critical operations for power companies, and their efficiency directly impacts the company's sustainable development. In recent years, with the widespread adoption of intelligent technologies, smart meters have been promoted and applied in power companies, driving transformation in meter reading and billing operations. The integrated application of smart meters and meter reading, verification, and billing information systems has become a key developme
Echo
09/01/2025
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!