• 145kV  Dead Tank SF6  Circuit Breaker
145kV Dead Tank SF6 Circuit Breaker
discuss personally
Model
LW-145
Basic info
Brand ROCKWILL
Model NO. 145kV Dead Tank SF6 Circuit Breaker
Rated voltage 145kV
Rated frequency 50/60Hz
Series LW
Product Detail

Description:

The 145kV dead tank SF6 circuit breaker is a high-reliability high-voltage device designed to ensure stable operation of power systems. It adopts a dead tank structure, with live parts sealed in a metal casing filled with SF6 gas, ensuring rapid arc extinction and efficient fault current interruption to safeguard grid safety. The low-center-of-gravity design gives it strong seismic resistance, adapting to harsh environments such as extreme climates. The equipment integrates bushings and current transformers to support multi-functional control such as measurement and protection. With long mechanical/electrical life and a sealed structure, maintenance frequency is significantly reduced. Equipped with anti-misoperation interlocking devices, it ensures the safety of personnel and equipment. Widely used in power, metallurgy, transportation and other fields, it performs excellently in medium and high voltage scenarios.

Product Advantages:

  • The spring operating mechanism of the circuit breaker is safe and stable, maintenance-free, and highly reliable, and meets the requirements of oil-free and gas-free operating mechanism.
  • Self-energy-compressed combined arc extinguisher.
  • The equipment is shipped after the lightning impact test, which eliminates the hidden danger of insulation discharge caused by production and assembly, and ensures the stable and reliable product quality.
  • The quality of the insulators is stable and reliable.
  • High parameterization: The technical parameters of the products are all of the highest standards in the industry.
  • The domestic first-class design team, suppliers and internal control system ensure the safety, stability and reliability of the products, and the products and inspection standards manufactured in the factory have been recognized by the State Grid and the Southern Power Grid Supervision.
  • Using advanced R&D tools such as finite element analysis software, functional analysis, whole-process quality characteristic chain, size chain analysis, potential failure mode and effect analysis (FEMA), etc., the modular design is realized on the basis of ensuring the safety, stability and reliability of product performance.
  • Earthquake resistance of magnitude 9.

Product features:

  • Spring operating mechanism, reliable performance;
  • Excellent breaking performance
  • E2-M2-C2 circuit breaker, electrical life 20 times, mechanical life 10000 times.
  • Strong rated flow capacity;
  • Excellent insulation level, small local discharge;
  • Excellent corrosion resistance;
  • Advanced design tools;
  • Strict process assembly and quality control.

 Use of the environment:

  • Installation location: indoor/outdoor;
  • Ambient air temperature :
  • Maximum temperature: +55°C;
  • Minimum temperature: -40°C; Maximum daily temperature difference: 32 K;
  • Altitude: ≦3000m;
  • Sunshine intensity (noon on sunny day): 1000 W/㎡;
  • Pollution level: III./IV. grade;
  • Icing thickness: 10mm/20mm;
  • Wind speed/wind pressure: 34m/s (equivalent to 700Pa on the surface of the cylinder);
  • Humidity: average daily relative humidity: ≦95%; Monthly average relative humidity: ≦90%;
  • Earthquake resistance: nine degrees;
  • Horizontal acceleration: 0.3g;
  • Vertical acceleration: 0.15g.

Use of the product:

In densely populated areas, in harmony with existing buildings, in important and critical substations, in confined space substation expansions, in flexible retrofits and replacements, in places with heavy loads, for economical and reliable energy management, in power stations, etc.
LW58A-126/145 SF6 canister circuit breaker is one of the new generation of switchgear of Shanghai Siyuan High Voltage Switchgear Co., Ltd., which has won the trust of users with its compact design and reliable performance.
 
Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul
Vziman
08/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!