• 252kV outdoor self-energy power high voltage SF6 circuit breaker
252kV outdoor self-energy power high voltage SF6 circuit breaker
discuss personally
Model
LW58-252(W)/T5000-63
LW58-252(W)/T4000-50
Basic info
Brand ROCKWILL
Model NO. 252kV outdoor self-energy power high voltage SF6 circuit breaker
Rated voltage 252kV
Rated normal current 5000A
Rated frequency 50/60Hz
Rated short circuit breaking current 63kA
Series LW58-252
Product Detail

Product introduction:

The LW58-252(W) outdoor self-energy high-voltage SF₆ circuit breaker is designed for 252kV, 50Hz AC power systems, serving as a critical control and protection device for power grid interconnections. Utilizing SF₆ gas for arc quenching and insulation, it features a self-energy power arc extinguishing double-action interrupter structure paired with a new-type spring operating mechanism. Renowned for its robust switching capability, low operating power, low noise, and high reliability, its technical indicators align with advanced domestic and international counterparts.

This three-phase SF₆ circuit breaker upgrades from single-pole, single-mechanism operation to a three-phase mechanical linkage system driven by a single mechanism. This design reduces mechanical complexity, enhances three-phase linkage reliability, and eliminates the risk of single-phase misoperation.

Main characteristic:

  • Self-Energy Arc Extinguishing Technology: The double-action structure ensures stable breaking capacity under diverse loads.

  • High Operational Efficiency: Requires minimal operating power, with a mechanical life cycle of up to 10,000 cycles for prolonged reliability.

  • Superior Contact Design: Copper-tungsten arc contacts use integral sintering, withstanding high temperatures, minimal arc erosion, and over 20 full breaking operations.

Reliable Sealing & Insulation:

  • Annual SF₆ gas leakage rate < 0.5% via precision sealing technology.

  • Stringent dehumidification processes ensure SF₆ moisture content far below industry standards.

  • High insulation level with creepage distance > 31mm/kV.

Advanced Materials:

  • Arc extinguishing chamber valve plates use lightweight zinc-base alloy for stable gas dynamics and breaking performance.

  • Imported PTFE-composite nozzles offer excellent ablation resistance and consistent arc quenching.

  • Premium Components: Secondary circuit electrical units and SF₆ density relays are high-quality impact-resistant or joint-venture products.

  • Pure Spring Operating Mechanism: Forged from high-strength alloy steel, key components resist wear, ensuring low failure rates during frequent operations.

Main technical parameters:

1732504456227.png

Instructions on placing orders  : 

  • Model and format of the circuit breaker;

  • Rated electrical parameters (voltage, current, breaking current, etc);

  • Working conditions for using (environment temperature, altitude, and environment pollution level);

  • Rated control circuit electrical parameters (Rated voltage of energy-store moter and Rated voltage of opening, closing coil);

  • Names and quantities of spare items needed, parts and special equipment and tools (to be otherwise ordered);

  • The wire connecting direction of the primary upper terminal.

What are the main types of tank circuit breakers?

SF6 Gas-Insulated Circuit Breaker:

  • SF6 Gas-Insulated Circuit Breaker: Uses sulfur hexafluoride (SF6) gas as the insulating and arc-quenching medium. SF6 gas has excellent insulating properties and arc-quenching capabilities, allowing it to meet the high voltage and high current breaking and insulation requirements in a small space. It is widely used in high-voltage and ultra-high-voltage power systems.

Oil-Immersed Circuit Breaker:

  • Oil-Immersed Circuit Breaker: Uses insulating oil as the insulating and arc-quenching medium. Insulating oil has good insulating properties and heat dissipation capabilities, effectively extinguishing arcs and cooling the contacts. However, due to the fire risk and environmental pollution associated with insulating oil, its application range has gradually decreased. Currently, it is mainly used in specific situations where fire prevention requirements are not stringent.


Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
What are the common faults of low-voltage voltage transformers?
What are the common faults of low-voltage voltage transformers?
Open - Circuit Fault on the Secondary SideOpen - circuit in the secondary side is a typical fault of low - voltage voltage transformers, showing abnormal voltmeter readings (zero/fluctuation), faulty power meters, buzzing noises, and core overheating. When open - circuited, the secondary voltage spikes (no secondary current to balance the primary EMF), causing core saturation, flux distortion, and potential overheating/damage.Causes include loose terminals, poor contact, or human error. In low
Felix Spark
07/18/2025
Analysis of the Principle of Second - harmonic Restraint for Overcurrent Protection of Distribution Automation Switches
Analysis of the Principle of Second - harmonic Restraint for Overcurrent Protection of Distribution Automation Switches
Substance of Second - harmonic Restraint in Overcurrent ProtectionThe substance of second - harmonic restraint in overcurrent protection is to use the second - harmonic component to judge whether the current is a fault current or an excitation inrush current. When the percentage of the second - harmonic component to the fundamental - wave component is greater than a certain value, it is judged to be caused by the excitation inrush current, and the overcurrent protection is blocked.Therefore, the
Leon
07/18/2025
What are the typical connection methods for 35kV distribution lines?
What are the typical connection methods for 35kV distribution lines?
Typical Wiring Diagram of 35kV Line Radial π ConnectionWhen a 35kV line adopts a radial power grid structure, a single - side power supply or a double - side power supply radial type can be used according to the situation of the power supply points, and a loop - out interval is reserved at the end of the line.Typical Wiring Diagram of 35kV Line Radial T - ConnectionFor double - radial lines, it is advisable to select a double - side power supply. When the power supply points do not meet the r
Leon
07/18/2025
Why are the ground fault point and the accident point not at the same location?
Why are the ground fault point and the accident point not at the same location?
Fault Transfer VoltageIn low - voltage distribution systems, there is a type of personal electric shock accident where the accident occurrence point and the system fault point are not at the same location. This kind of accident occurs because after a ground fault happens elsewhere, the generated fault voltage is conducted to the metal casings of other equipment through the PE wire or PEN wire. When the fault voltage on the metal casing of the equipment is higher than the human - body safe voltag
Leon
07/18/2025
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!