| Muhimmiya | Schneider |
| Model NO. | 12~40.5kV AC metal-enclosed gas-insulated switchgear A C 12~40.5kV gas-insulated switchgear na ake kula da haɗuƙi |
| Rated Voltage | 40.5kV |
| Siri | WS-G 12~40.5kV |
Labarai
WS-G Daɗi Inganci Da Zan Iya Karkashin Yakin Aikinsu
Gas-insulated switchgear WS-G na Schneider Electric yana da inganci da zan iya karkashin yakin aikinsu mafi yawa, wanda ya iya taimakawa tsarin karamin birnin da za ta shirya da haɗin kwallon jiki. Ana amfani da interfacen bayanai na masu amfani don koyarwa, wanda ya iya taimakawa masu amfani don koyarwa. Switchgear WS-G ta dace da rike-rinkuna da ke nuna muhimmancin yakin aikinsu.
WS-G Daidaita Inyan Mataki
WS-G yana daidaita wa fadin da kuma kayayyaki na karamin birnin, infrastructures, mining, metallurgy, petrochemical, gas, railway power supply, container bases da marine industries.
WS-G yana amfani da gas-insulated switchgear da voltage rated zuwa 40.5kV, current rated zuwa 3150A, da kuma breaking current rated zuwa 40kA. Ana amfani da design concept na modern da inyan mataki, wanda ana da options da ma'ana suka ce don zan iya zaba da su.
WS-G an designed for single busbar ko double busbar system. Wannan switchgear mai kyau da modular yana da flexibility da kuma freedom of maintenance throughout its lifetime. Yana daidaita cikin places inda space yana da ƙwarewa ko inda za a canza switches da take da foundation.
WS-G yana daidaita wajen samun karfi da kuma zama economical. Ana iya samun karfi da kuma kawo da kanta, kafin a yi installation, extension, or removal. Saboda B-link innovative busbar connection, ba a buƙata da gas handling operations a site.
WS-G an test it according to IEC standards, European EN standards, Chinese GB standards, and other national standards.
Fadada Masu Amfani
Ba a buƙata da gas handling don expansions da cabinet replacement
Innovative, fault-resistant busbar connections
Friendly operation interface
Operational reliability and safety of personnel handing
Low lifetime costs
Environmentally friendly and easy to recycle
Fadada da Ingancin WS-G

Innovative B-Link improves busbar connection
The busbar of each ws-g switchgear is installed in an independent inflatable chamber according to the system requirements. They are integrated into the insulating gas monitoring system and are not affected by the external environment. The connection with the adjacent switch cabinet bus is through our innovative bus connection system: B-link connection.
B-link connection system ba a buƙata da any maintenance. It is easy to install at the user's site and does not require gas treatment. When expanding or replacing the switchgear, no gas handling is required and the gas chamber is not affected. The B-link connection system does not require any maintenance. It is easy to install at the user's site and requires no gas handling. When expanding or replacing the switchgear, no gas handling is required and the gas chamber is not affected. The voltage control technology, housing grounding, soft and durable silicone rubber insulation used in the B-link connection system make the connection of the switchgear easier and the electric field distribution more uniform.
Further advantages of the B-Link system include:
All silicone rubber insulation parts have been installed on the switch cabinet in the factory, and partial discharge test has been conducted.
The on-site installation of B-link system is visible. When the B-link connection system of the adjacent switch cabinet is disassembled, an insulation distance is formed between the separated busbars without gas treatment. If necessary, the resistance of each section of busbar can be measured separately for the entire busbar system or one switchgear.

Reducing space requirements and improving space utilization
WS-G saves investment costs due to its small space footprint. WS-G can replace the old switchgear in the existing power distribution room. When the existing switchgear is dismantled, the WS-G can be debugged in sections. Reduce power outages.
WS-G is designed for standard wall mounting. It does not require installation channels. All operations and maintenance procedures can be done in front of the cabinet.
Freestanding mounting options is also available.
Improved switchgear management - no gas handling required on site
WS-G does not require gas treatment for installation or expansion in the field. All inflatable chambers delivered to the site for installation have a rated inflation pressure. All inflatable chambers have been tested for leakage prevention in the factory.
No gas treatment is required for the installation and renewal of the switch cabinet on site, and it does not affect the plenum.
Operating conditions and technical characteristics
Surrounding environment and working conditions
WS-G series switchgear is recommended to operate under normal working conditions in accordance with IEC62271, GB11022/T and GB 3906 standards.

Technical characteristics

WS-G main wiring scheme
Typical scheme
Single busbar system

Typical scheme
Dual busbar system

Typical scheme
Busbar auxiliary module

Cabinet arrangement (Single busbar segmentation)

WS-G application example
Spatial distribution map of civil engineering