| Brand | Switchgear parts | 
| Numero sa Modelo | 12kV eco-friendly nga fully sealed (air insulated without SF6 gas) upper isolation circuit breaker switch | 
| Naka nga boltahang rated | 12kV | 
| Rated Current | 630A | 
| Rated na nga kusog sa pag-abli sa short circuit | 25kA | 
| Serye | KHV-12 | 
Ang serye niini nga eco-friendly nga gas insulated switch gamit ang epoxy resin aron mopressure inject sa tri-phase vacuum arc extinguishing chamber. Ang epoxy resin usa ka malampuson nga gipanggamit nga insulating material sa industriya, ug tungod sa iyang excellent nga insulation performance ug mataas nga material stability, gigamit na kini giwahan sa electrical industry. Ang insulation medium sa switch sa high-voltage cabinet mao ang zero grade dry air o 99.99% pure N gas nga naghimo sa GB/T8979-2008. Ang main circuit arc extinguishing system sa switch body gibale sa pole, ug adunay busbar overlap surface sa itaas nga bahin sa static knife, labi ka convenient alang sa busbar overlap. Ang serye niini nga mga switch gitugyan sa operating mechanism nga independiente nga giproduktahan sa kompanya. Ang buong cabinet application adunay kompleto nga mechanism interlocking function, ug ang operating mechanism nagpahimulos sa pito ka prevention requirements sa power distribution system. Kini usab makapag-expand sa installation program lock, lock, flexible configuration sa secondary auxiliary, ug customize special application solutions para sa uban-uban nga proyekto.
Model description

| Serial Number | Item | Unit | Parameter | Remark | 
|---|---|---|---|---|
| 1 | Rated Voltage | kV | 12 | |
| 2 | Rated Current | A | 630 | |
| 3 | Rated Breaking Current / Thermal Stability Time | kA/s | 20/4; 25/3 | |
| 4 | Rated Peak Withstand Current | kA | 50/63 | |
| 5 | Rated Short-circuit Making Current | kA | 50/63 | |
| 6 | Short-circuit Making Times | times | 30 | |
| 7 | Power Frequency Withstand Voltage: Phase-to-Ground / Phase-to-Phase | kV | 42 | In Dry Air or N₂ | 
| 8 | Power Frequency Withstand Voltage: Break | kV | 48 | In Dry Air or N₂ | 
| 9 | Lightning Impulse: Phase-to-Ground / Phase-to-Phase | kV | 75 | In Dry Air or N₂ | 
| 10 | Lightning Impulse: Break | kV | 85 | In Dry Air or N₂ | 
| 11 | Main Circuit Resistance | μΩ | ≤60 | Vacuum Arc Extinguishing Chamber + Disconnector | 
| 12 | Mechanical Life of Arc Extinguishing Chamber | times | 10000 | |
| 13 | Mechanical Life of Isolation / Earthing Switch | times | 5000 | |
| 14 | Gas Tank Pressure | bar | 1.25 | 
Installation dimensions

 
                                         
                                         
                                         
                                         
                                        