interruptrix circuitalis superior isolata sine gas SF6 insulata aere pro IEE-Business

  • 12kV environmentally friendly fully sealed (air insulated without SF6 gas) upper isolation circuit breaker switch

Attributa principalia

Marca Switchgear parts
Numerus Modeli interruptrix circuitalis superior isolata sine gas SF6 insulata aere pro IEE-Business
Votum nominatum 12kV
currus electricus nominatus 630A
currentis rumpendi nominale in circuitu commutato 25kA
Series KHV-12

Descriptiones productorum a fornitori

Descriptio

Haec series commutatorum insulatorum gas insulatis amicae ambienti utitur resina epoxyda ad injectionem pressionis in camera arcus extinguendi vacui triphasica. Resina epoxyda est materialis insulator communis in industria, et propter eius excellentem qualitatem insulatoriam et stabilitatem materialis altam, late usus est in industria electrica. Medium insulatorius commutatoris in armario alta tensio est aer siccus gradus nihili vel N gas puritas 99.99% conformis GB/T8979-2008. Systema arcus extinguendi circuiti principali corporis commutatoris inclusum est in polo, et superne in cultro statico est facies superpositiva busbar, quae valde facilis est ad superpositionem busbar. Haec series commutatorum coniuncta est cum mechanismo operationis a societate independenter producta. Totum armarium applicationis habet functionem interlocking mechanismi integram, et mechanismus operationis satisfacit requirimentis quinque praeservationis systematis distributionis electricitatis. Potest etiam expandere programmam installationis luculum, luculum, flexibiliter configurare auxilia secundaria et specialia solutiones applicationis diversis projectis.

Descriptio modello

Numerus serii Item Unitas Parametri Notatio
1 Tensio nominata kV 12  
2 Currens nominatus A 630  
3 Currens ruptura nominatum / Tempus stabilitatis thermicae kA/s 20/4; 25/3  
4 Currens picus nominatus sustentabilis kA 50/63  
5 Currens brevis factus nominatus kA 50/63  
6 Tempora facta brevis tempora 30  
7 Tensio sustentabilis frequentialis: Phase ad terram / Phase ad phase kV 42 In aere sicco vel N₂
8 Tensio sustentabilis frequentialis: Ruptura kV 48 In aere sicco vel N₂
9 Impulsus fulminis: Phase ad terram / Phase ad phase kV 75 In aere sicco vel N₂
10 Impulsus fulminis: Ruptura kV 85 In aere sicco vel N₂
11 Resistentia circuiti principali μΩ ≤60 Camera arcus extinguendi vacua + disjunctorem
12 Vita mechanica camerae arcus extinguendi tempora 10000  
13 Vita mechanica disjunctoris / interruptoris terreni tempora 5000  
14 Pressio vasculi gas bar 1.25  

Dimensiones installationis

 

FAQ
Q: Quid est commutator circuitus disiunctivus cum isolatione superpositus in armario ecologicum et quae sunt eius functiones cardinales
A:

Est pars integrata componentis electrici, installata in parte superiore armarii aerei insulati sine SF6, combinans functiones commutatoris disiunctionis et interruptoris circuitus. Functiones cardinales eius tria sunt: ① Duplex protectio & disiunctio: potest secare currentem normalis oneris et currentem faultae circuitus brevis, et post aperturam creare intervallum insulatum visibile ad securitatem manutentionis assecurandam; ② Interlocking securitatis: mechanice interconnectat cum ianuis armarii, commutatoribus terrae et busbar principalibus, ut evitet operationes erroneas sicut disiunctio viva et clausura cum earthing; ③ Conformitas environmentalis: adoptat insulationem aeream sine gas SF6, vitans effectum hothouse et producta decompositionis venenosa, in lineam cum globalibus politicis low-carbon. Largiter usurpatur in systematibus distributionis mediae tensionis 10kV/12kV sicut substationes et parcos industriales.

Q: Cur uestus interruptor separativus superpositus aptus est pro armariis ecologicis sine SF6?
A:

Coniunctio fundatur in requisitis pro tutela ambientali et compatibilitate structurale duobus rationibus principali: ① Coniunctio ad tutelam ambientalem: Adoptat designum insulationis aeris, quod perfecte congruit cum attributo nucleo "SF6-liber" armariorum ecologicorum, evitans pericula iuris de restrictione SF6; ② Compatibilitas structurale: Positio installationis supera est propinqua bus ductui principali armariorum ecologicorum, breviens longitudinem connectionis bus ductus, minuens dissipationem potentiae et meliorans stabilitatem operationis; ③ Commoditas manutentionis: Positio superior facilis aditus, minuens difficultatem manutentionis in situ et breviens tempus manutentionis. In systematis medi-voltalibus 10kV/12kV, intervallum insulationis aeris (≥125mm) potest plene satisfacere requisitis insulationis

Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 1000m² Numerus omnium laborantium: Summa Annua Exportatio (USD): 300000000
Locus Operis: 1000m²
Numerus omnium laborantium:
Summa Annua Exportatio (USD): 300000000
Servitia
Genus Negotii: Venditio
Categorias Principales: pars componentium/Instrumenta inspectionis/apparatus electrum altum voltus/Apparatus electri bassa tensione/Instrumenta et mensurae/Instrumenta productiva/Ferramentae electricitatis
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026
  • Quid est Differentia Inter Transformatores Rectificatores et Transformatores Potentiae?
    Quid est transformator rectificans?"Conversio potentiae" est terminus generalis qui conversionem, inversionem et conversionem frequentiae comprehendit, inter quas conversio praecipue usitatissima est. Apparatus rectificans convertit potentiam AC input in DC output per rectificationem et filtrationem. Transformator rectificans servit ut transformator alimentationis pro talibus apparatibus rectificantibus. In applicationibus industrialibus, plerumque alimenta DC obtinentur per combinandum transfor
    01/29/2026
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum