12KV amicus naturae (aeris insulatus sine SF6 gas) interruptor circuiti vacui (superior isolatio)

  • 12KV environmentally friendly (air insulated without SF6 gas) vacuum circuit breaker switch (upper isolation)
  • 12KV environmentally friendly (air insulated without SF6 gas) vacuum circuit breaker switch (upper isolation)

Attributa principalia

Marca Switchgear parts
Numerus Modeli 12KV amicus naturae (aeris insulatus sine SF6 gas) interruptor circuiti vacui (superior isolatio)
Votum nominatum 12kV
currus electricus nominatus 630A
currentis rumpendi nominale in circuitu commutato 25kA
Series VHK-12

Descriptiones productorum a fornitori

Descriptio

Circuitus interruptor isolatus sub armario VHK-12 ad protectionem ambientalem adoptat structuram semiclausam, quae habet praestantias electrici campi aequabilis, disiunctionis fidelem, longam vitam servitii, manutentionis nullam et installationem facilem. Hoc productum principaliter utitur in armariis annularibus aer insulatis ambiens conservantes. Ut component principale intra armarium, id gerit functiones circuiti principalem claudendi et aperiendi, et habet functiones claudendi et aperiendi currentem oneris nominati et claudendi et disiungendi currentem circuitus brevis.
Conditiones ambientales ad usum:
1) Temperatura ambientalis: maxima temperatura +40 ° C, minima temperatura -15 ° C (depositio et transportatio permittuntur ad -30 ° C);
2) Altitudo: ≤ 2000 metrorum;
3) Humiditas ambientalis: media relativa diurna humiditas <95%, media relativa mensualis humiditas ≤ 90%;
4) Intensitas seismica: non superans octo gradus;
5) Locus usus: absque periculo inflammabilium vel explosibilium, absque vaporisatione aquae, gasibus corrosivis, vel vibrationibus gravis
Pro scenariis usus specialibus qui differunt ab conditionibus operationis normalibus, usor producti debet convenire cum manufactore. Exempli gratia, quando instrumenta electrica installantur ad altitudine super 2000 metrorum, instructiones speciales debent fieri ut manufactus productum adiustet in productione.

Descriptio modeli

Parametri producti

Numerus serialis Item Unitas Parameter Notula
1 Tensio nominata KV 12  
2 Currentus nominatus A 630  
3 Currentus disiunctionis nominatus / Tempus stabilitatis thermicae KA/S 20/4; 25/3  
4 Currentus peak sustinendus nominatus KA 50/63  
5 Currentus circuitus brevis faciendi nominatus KA 50/63  
6 Tempora faciendi circuitus brevis tempora 30  
7 Tensio sustinenda frequentiae potentiæ: Phase-to-Ground / Phase-to-Phase KV 42 In aere sicco vel N₂
8 Tensio sustinenda frequentiae potentiæ: Disiunctio KV 48 In aere sicco vel N₂
9 Impulsus fulminis: Phase-to-Ground / Phase-to-Phase KV 75 In aere sicco vel N₂
10 Impulsus fulminis: Disiunctio KV 85 In aere sicco vel N₂
11 Resistentia circuiti principalem μΩ ≤60 Camera extinguendi arcum vacuo + disiunctio
12 Vita mecanica camerae extinguendi arcum tempora 10000  
13 Vita mecanica disiunctionis / commutationis terre tempora 5000  
14 Pressio vasculi gasei bar 1.25  

Dimensiones installationis

Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 1000m² Numerus omnium laborantium: Summa Annua Exportatio (USD): 300000000
Locus Operis: 1000m²
Numerus omnium laborantium:
Summa Annua Exportatio (USD): 300000000
Servitia
Genus Negotii: Venditio
Categorias Principales: pars componentium/Instrumenta inspectionis/apparatus electrum altum voltus/Apparatus electri bassa tensione/Instrumenta et mensurae/Instrumenta productiva/Ferramentae electricitatis
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026
  • Quid est Differentia Inter Transformatores Rectificatores et Transformatores Potentiae?
    Quid est transformator rectificans?"Conversio potentiae" est terminus generalis qui conversionem, inversionem et conversionem frequentiae comprehendit, inter quas conversio praecipue usitatissima est. Apparatus rectificans convertit potentiam AC input in DC output per rectificationem et filtrationem. Transformator rectificans servit ut transformator alimentationis pro talibus apparatibus rectificantibus. In applicationibus industrialibus, plerumque alimenta DC obtinentur per combinandum transfor
    01/29/2026
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum