• 110kV Class oil-immersed transformer
  • 110kV Class oil-immersed transformer
  • 110kV Class oil-immersed transformer
110kV Class oil-immersed transformer
discuss personally
Model
SFSZ-90000/121
SFSZ-90000/110
SFSZ-63000/121
SFSZ-63000/110
SFSZ-50000/121
SFSZ-50000/110
SFSZ-40000/121
SFSZ-40000/110
SFSZ-31500/121
SFSZ-31500/110
SFSZ-25000/121
SFSZ-25000/110
SFSZ-16000/121
SFSZ-16000/110
SFSZ-12500/121
SFSZ-12500/110
SFSZ-10000/121
SFSZ-10000/110
SFSZ-8000/110
SFSZ-8000/121
SFSZ-6300/121
SFSZ-6300/110
SFS10-90000/121
SF10-90000/121
SFS10-90000/110
SF10-90000/110
SFS10-50==63000/121
SF10-63000/121
SFS10-63000/110
SF10-63000/110
SFS10-50000/121
SF10-50000/121
SFS10-50000/110
SF10-50000/110
SFS10-40000/121
SF10-40000/121
SFS10-40000/110
SF10-40000/110
SFS10-31500/121
SF10-31500/121
SFS10-31500/110
SF10-31500/110
SFS10-25000/121
SF10-25000/121
SFS10-25000/110
SF10-25000/110
SFS10-20000/121
SF10-20000/121
SFS10-20000/110
SF10-20000/110
SFS10-16000/121
SF10-16000/121
SFS10-16000/110
SF10-16000/110
SFS10-12500/121
SF10-12500/121
SFS10-12500/110
SF10-12500/110
SFS10-10000/121
SF10-10000/121
SFS10-10000/110
SF10-10000/110
SFS10-8000/121
SF10-8000/121
SFS10-6300/110
SF10-8000/110
SFS10-6300/121
SF10-6300/121
SFS10-6300/110
SF10-6300/110
Basic info
Brand ROCKWILL
Model NO. 110kV Class oil-immersed transformer
Rated capacity 8000kVA
Primary voltage 121kV
Secondary voltage 6.3kV
Methods of regulation N/A
Winding type Three Winding
Series SF/SFS Series
Product Detail

Overview

Premium Durability: Superior insulation and mechanical resilience allow for extended system life and overall system reliability.reducing the frequency of outages. 

Certified Quality: Oil-immersed power transformers are manufactured, tested and delivered in our accordance with all applicable standards (ANSI, IEEE) maintaining US compliance which simplifies service and retrofitting.

Energy Efficient: Designed to accommodate heavier base loading for extended periods of time with low energy loss and minimal partial discharge for optimized energy savings.

 

Operating condition

1.working temperature:-30℃~40℃

2.Relative humidity: ≤90% (25℃) 

3.No corrosive gas, no obvious dirt, etc.

4.Altitude: ≤1000m

 

Applications:

The 110kV power transformers that are primarily used in high-voltage transmission and substation applications to step up or step down voltage for efficient power distribution. Common applications include utility grid substations, large industrial plants, renewable energy integration (wind and solar farms), and heavy infrastructure projects.


If you need to know about more parameters , Please check the model selection manual.↓

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!