Customization 7.2kV 10kV 15kV 15.5kVclass S13 series oil immersed fully sealed power transformer

  • Customization 7.2kV 10kV 15kV 15.5kVclass S13 series oil immersed fully sealed power transformer

Key attributes

Brand ROCKWILL
Model NO. Customization 7.2kV 10kV 15kV 15.5kVclass S13 series oil immersed fully sealed power transformer
Rated voltage 10kV
Rated frequency 50/60Hz
Rated capacity 200kVA
Series S13

Product descriptions from the supplier

Description

Product Description

As a pioneer in China's power transformer industry, we have specialized in the R&D and manufacturing of power transformer equipment for decades, and established industry standards with core technologies.

The  7.2kV 10kV 15kV 15.5kV Class S13 Series Oil-Immersed Fully Sealed Power Transformer is a high-efficiency distribution transformer designed for reliability and longevity. As part of the S13 series, it meets stringent energy efficiency standards, significantly reducing no-load losses compared to conventional models. Its fully sealed, oil-immersed construction eliminates the need for a conservator, preventing insulating oil from contacting ambient air and moisture. This makes it an exceptionally robust and maintenance-free solution for continuous operation in utility and industrial power distribution networks.

This power transformer is fully compliant with international standards including IEC 60076-1, IEEE C57.12.00, ANSI C57.12.90, AS/NZS 60076.5 and EN 61558-1. It meets quality requirements and is widely adaptable to the operational needs of power grids in multiple overseas regions.

Product model

  • S: Three-phase

  • 13: Performance Level

  • M: Fully Sealed

  • □: Rated Capacity (kVA)

  • □: Rated High Voltage

Conditions of use

  • Altitude: No more than 1000m, indoor or outdoor.

  • Ambient temperature: The highest ambient air temperature is +40℃, the highest daily average temperature is +30℃, maximum annual average temperature is +20℃, and the minimum temperature is -25℃.

  • Transformers can be provided to operate under special conditions according to user requirements.

Performance Parameters: Technical Parameters of S13-30~3150/10kV Series Oil-immersed Fully Sealed Power Transformer

The voltage classes of some of these Power Transformer include 6kV, 6.3kV, 6.6kV, 6.9kV, 7.2kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV, 13.2kV, 13.8kV, 14.5kV, 14.4kV, 15kV, 15.5kV, 15.6kV, 17.5kV, 20kV, 21.9kV, 22kV, 24kV, 30kV, 33kV, 33.5kV, 34.5kV, 35kV, 36kV, 38kV, 38.5kV, 40.5kV, 44kV, 45kV, 46kV, 66kV  69kV.72.5kV 88kV 110kV 115kV 123kV 125kV 126kV 132kV 138kV 145kV 150kV 154kV 161kV 170kV  220kV 225kV 230kV 245kV 275kV 330kV 345kV 363kV 380kV 400kV 500kV Power transformers of voltage ,and aboveand customization is available.

Model

Capacity (kVA)

Rated Voltage

Connection Group

No-load Loss (W)

Load Loss (W)

No-load Current (A)

Short-circuit Impedance %

Weight

Outline Dimensions

 (Length * Width * Height mm)

Gauge

High Voltage (kV)

Low Voltage (kV)

Oil Weight (kg)

Core Weight (kg)

Total Weight (kg)

S13-M-30/10

30

6

6.3

10

10.5

11

 

 

 

 

 

Voltage Regulation Range ±5% or ±2×2.5%


0.4

Dyn11

Yyn0

80

630

1.4

4.0

90

200

400

1050 * 630 * 1040

400 * 400

S13-M-50/10

50

100

910

1.2

100

220

460

1020 * 680 * 1080

S13-M-63/10

63

110

1090

1.1

110

250

500

1060 * 690 * 1090

S13-M-80/10

80

130

1310

1.0

115

290

550

1070 * 700 * 1100

S13-M-100/10

100

150

1580

0.9

120

350

620

1090 * 710 * 1120

S13-M-125/10

125

170

1890

0.8

145

390

700

1130 * 730 * 1180

S13-M-160/10

160

200

2310

0.8

175

460

830

1160 * 750 * 1180

550 * 550

 

S13-M-200/10

200

240

2730

0.7

190

520

910

1190 * 750 * 1260

S13-M-250/10

250

290

3200

0.7

200

610

1000

1230 * 770 * 1280

S13-M-315/10

315

350

3830

0.6

220

730

1430

1280 * 830 * 1290

S13-M-400/10

400

410

4520

0.5

260

900

1430

1310 * 830 * 1340

660 * 660

S13-M-500/10

500

490

5410

0.5

280

1000

1600

1389 * 890 * 1380

S13-M-630/10

630

580

6200

0.4

4.5

330

1100

1830

1490 * 980 * 1410

S13-M-800/10

800

700

7500

0.4

450

1280

2300

1560 * 1000 * 1560

820 * 820

S13-M-1000/10

1000

830

10300

0.4

550

1450

2700

1700 * 1130 * 1650

S13-M-1250/10

1250

980

12000

0.3

630

1800

3200

1830 * 1230 * 1710

S13-M-1600/10

1600


1180

14500

0.3

800

2100

3700

1880 * 1270 * 1790

S13-M-2000/10

2000

1410

17400

0.3

5.5

1050

2600

4500

1980 * 1310 * 1900

920 * 920

S13-M-2500/10

2500

1660

20240

0.3

1200

3100

5500

2360 * 1580 * 2300

S13-M-3150/10

3150

1980

24100

0.3

1400

4100

7200

2700 * 1780 * 2500

Note: for transformers rated at 500 kva and below, the load loss values above the diagonal lines in the table apply to dyn 11 or yzn 11 connection groups, and the load loss values below the diagonal lines apply to yyno connection groups.

Key Technical Features

  • High Energy Efficiency (S13 Class):Incorporates advanced core materials and design to achieve superior energy performance, notably lowering no-load losses and resulting in substantial cost savings over the transformer's lifetime.

  • Fully Sealed, Maintenance-Free Design:The hermetically sealed tank with corrugated or smooth tank walls ensures no breathing of the insulating oil. This prevents oxidation and moisture absorption, eliminating the need for periodic oil filtration or testing.

  • Enhanced Reliability and Durability:The sealed construction protects the internal insulation system from environmental contaminants and humidity fluctuations, ensuring stable dielectric strength and a long service life even in harsh conditions.

  • Robust Oil-Immersed Technology:Provides excellent heat dissipation and overload capacity. The insulating oil effectively cools the core and windings, allowing for reliable performance under peak load demands.

  • Safe and Environmentally Considerate:Designed with pressure relief devices for safety. The sealed system minimizes the risk of oil leakage, protecting the surrounding environment.

 

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.