• ​Digital Multi-function Power Meter
  • ​Digital Multi-function Power Meter
  • ​Digital Multi-function Power Meter
​Digital Multi-function Power Meter
$15.00
Model
RQY-72E
RQY-80E
RQY-96E
Basic info
Brand Wone Store
Model NO. ​Digital Multi-function Power Meter
size 80*80mm
Series RQY
Product Detail

The Digital Multi-function Power Meter is a modern power monitoring core device that integrates high-precision measurement, comprehensive monitoring, and intelligent communication. Utilizing a clear and intuitive digital display interface, it provides full-spectrum real-time data of the power system for you. It is the ideal choice for realizing fine-grained energy consumption management, enhancing operational efficiency, and ensuring power supply security in industrial automation, building management, data centers, and power distribution systems.

Core Functions, At a Glance:

  • Precision Measurement: Monitors critical electrical parameters including three-phase/single-phase voltage, current, active/reactive/apparent power, power factor, frequency, etc., in real-time, with leading accuracy (high precision).

  • Energy Metering: Accurately meters active energy and reactive energy (import/export), providing a reliable basis for energy consumption analysis and billing.

  • Power Quality Insight: Offers optional monitoring of power quality parameters such as harmonic content, voltage/current unbalance, etc., aiding in optimizing power supply quality.

  • Clear Display: Employs a high-brightness LED or LCD display (typically dual-row or multi-row), presenting data clearly and intuitively with rich information, facilitating fast on-site reading.

  • Flexible Communication: Integrates standard communication interfaces such as RS485, supporting mainstream industrial protocols like Modbus-RTU, Profibus, CANopen (depending on model configuration), enabling seamless integration into SCADA, EMS, BMS and other systems for remote monitoring and data acquisition (SCADA).

  • Intelligent Alarming: Provides out-of-limit alarm functionality, promptly detecting potential risks such as voltage anomalies or current overload.

  • Data Logging: Certain models feature historical data logging capability, facilitating history tracing and analysis.

Product Advantages, Worthy of Trust:

  • High Accuracy and Reliability: Ensures stable measurements and accurate, trustworthy data, meeting high-standard application requirements.

  • Comprehensive Function Integration: Addresses multiple monitoring needs with a single meter, reducing installation complexity and cost.

  • Convenient and Flexible Installation: Offers multiple form factors (square or DIN-rail mounted), allowing easy adaptation to various distribution panels/cabinets (switchboard/cabinet).

  • Powerful Compatibility: Utilizes standard communication protocols, ensuring easy integration with existing systems.

  • Rugged and Durable: Features an industrial-grade design, wide operating temperature range (e.g., -25°C to +70°C), and strong interference resistance (high immunity).

  • Assists Energy Efficiency Enhancement: Provides precise data support for energy audits and energy-saving renovations.

Technical Specifications:

Parameter Specification
Connection Three-phase four-wire Y34 / Three-phase three-wire V33
Signal Input - Voltage Range 400V / 100V
Signal Input - Voltage Overload Continuous: 1.2x, Instantaneous: 2x
Signal Input - Voltage Consumption < 1VA
Signal Input - Current Range 5A / 1A
Signal Input - Current Overload Continuous: 1.2x, Instantaneous: 2x
Signal Input - Current Consumption < 1VA
Frequency 40-65Hz
Power Supply AC220V (default) or AC/DC 80-270V
Energy Pulse Output Passive optocoupler collector output
Pulse width: 80ms ±20%
Communication • Interface: RS485 (physically isolated)
       • Protocol: MODBUS-RTU
       • Baud rate: 1200-9600 bps
       • Parity: N81/E81/O81
Analog Output • Range: 0/4-20mA or 0-5/10V
       • Configurable variables via programming
Relay Output • Type: Programmable alarm/trip relay
       • Rating: 5A/250V AC, 5A/30V DC
       • Trigger sources: Battery alarm, DI, AI, remote
Digital Input (DI) • Type: Dry contact
       • Function: Programmable alarm mapping
Accuracy Class • Voltage/Current: 0.5
       • Active Energy: 0.5S
       • Reactive Energy: 1.0
       • Frequency: ±0.1Hz
Display High-definition LCD (integrated nixie tube type)
Environmental • Operating: -10°C to +55°C
       • Storage: -20°C to +75°C
Safety Standards • Insulation resistance: >5MΩ (signal/power/earth)
       • Dielectric strength: >2kV AC (signal/power/output)

Wiring diagram:
  Wiring diagram.png


Know your supplier
Wone Store
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/MV & LV CT PT/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!