China

Misalai Insulation Resistance na Maida

A nan tsari insulation resistance da ita ce mafi yawan karamin birnin kasa daga insulation zuwa amfani da shi.

Maida insulation resistance yana da muhimmanci. A gaba na lura ne suka yi karatu a wasu lokaci bayan a yi amfani da test voltage. Tsari na amfani da voltage suna cikin 1 minute ko 10 minutes. Saboda haka, za a iya kiran insulation resistance a matsayin 1 minute insulation resistance ko 10 minute insulation resistance idan an yi wata wannan lokacin.
NB: – Amfani da voltage na maida insulation resistance yana cikin birnin kasa.
Idan a yi amfani da birnin kasa across the insulation, zai faru
current kan insulation. Wannan current yana da biyu masu muhimmiyar banga.

  1. Current da ke faru across leakage path over the surface of the solid insulator. Wannan leakage path yana form mainly saboda moisture, dust etc. wadanda suka jiha natural ce a tsakiyar solid insulator.

  2. Current da ke faru through the volume of the insulator body.

Na biyu a cikin current yana cikin uku masu muhimmiyar banga kamar yadda ake bayyana a cikin:

  • Saboda insulation materials suna cikin dielectric nature, zai faru capacitive charging current, ba tare da application of test voltage. Wannan current yana instantaneous in nature. Zai zama da wuya a fadada lokaci. Saboda haka, wannan current ba sa iya samun wani takarda a cikin karatu idan an yi shi bayan 1 minute ko daidai.

  • Akwai wata banga a cikin current da ake kira absorption current. Yana decay from high value to zero. The insulation resistance value taken within first few minutes of test is largely dominated by absorption current.

  • Wata kuma da muhimmiyar banga a cikin current shine conduction current. Yana basta da wuri throughout the insulation resistance test. Saboda haka, ba tare da charging current then absorption current becomes insignificant, the test result is mainly predominated by this conduction current.

Sannan kafin a yi karatu insulation resistance, leakage current and conduction current ne suka faru.
Saboda haka, karatu insulation resistance yana da yawa a yi bayan 15 seconds ko 1 minute ko sometimes after 10 minutes during the test.

Hanyar Maida Insulation Resistance

Akawo kimiyya da ake amfani da su don maida insulation resistance wa electrical equipment.

  1. Direct-indicating ohmmeter with hand driven dc generator. Wannan ya fi sani a wurin da ake kiran hand driven megger saboda Megger shine wanda ya fi shahara a matsayin mai ban sha wannan instrument.

  2. Direct-indicating ohmmeter with motor driven dc generator. Wannan ya fi sani a wurin da ake kiran motorized megger.

  3. Direct-indicating ohmmeter with self-contained battery.

  4. Direct-indicating ohmmeter with self-contained rectifier. Wannan instrument takes power from an external AC supply.

  5. Resistance bridge circuit with self-contained galvanometer and battery.

Za a iya yi measurement of insulation resistance with an external dc supply. In that case, we take voltage and current reading with the help of a dc voltmeter and a micro ranged dc ammeter, respectively.

In that case, we can calcula the insulation resistance with the help of ohm’s law

Where, V is the voltmeter reading and I is the ammeter reading.

The ammeter is micro ranged because, a very tiny current passes through the insulation during test and he current is in that range only. But at the moment of voltage application, the micrometer has to take initial capacitive charging current as well as absorption current. So the ammeter should be capable of withstanding both of these currents for at least initial duration. The voltmeter, ammeter and source should also be capable of withstanding short circuit current in the case of insulation failure if occurs during measurement.

When we use direct indicating ohmmeter of simply megger, the leads of the instrument are connected across the insulator to be tested. After driving the instrument the value of insulation resistance is indicated on the analog or digital dial of the instrument directly.
In both of the above-mentioned methods of insulation resistance measurement, the reading is taken after a standard time delay to get more accurate and error-free reading.

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Ba da kyau kuma kara mai rubutu!
Tambayar Da Yawanci
Istifararsa Dukkantar THD Don Tarihin Kirkiro na Sisinta Tsakiya
Istifararsa Dukkantar THD Don Tarihin Kirkiro na Sisinta Tsakiya
Toleransi Eror dari Distorsi Harmonik Total (THD): Analisis Komprehensif Berdasarkan Skenario Aplikasi, Ketepatan Alat, dan Standar IndustriRentang toleransi eror untuk Distorsi Harmonik Total (THD) harus dievaluasi berdasarkan konteks aplikasi spesifik, ketepatan alat pengukuran, dan standar industri yang berlaku. Berikut ini adalah analisis mendalam dari indikator kinerja utama dalam sistem tenaga, peralatan industri, dan aplikasi pengukuran umum.1. Standar Eror Harmonik dalam Sistem Tenaga1.1
Edwiin
11/03/2025
Kabilarin Yakin Da Kasa a 24kV Eco-Friendly RMUs: Yadda Da Kyau & Yadda A Yi
Kabilarin Yakin Da Kasa a 24kV Eco-Friendly RMUs: Yadda Da Kyau & Yadda A Yi
An samun hanyar inganci da kuma hanyar ingancin hawa mai sauya shi ne abu na gurbin 24 kV ring main units. Tare da hanyar ingancin hawa mai sauya shi, za a iya lalace da ci gaban inganci ko kuma cikakken fase da kyau zuwa rayuwar. Tabbacin pole ya zama yadda ake taimaka da hanyar ingancin hawa mai sauya shi da kuma magana da vacuum interrupter da kuma mafi girman adadin adadin.Don 24 kV outgoing busbar, idan an rike fase spacing a 110 mm, maka vulcanizing wajen busbar ya zama yadda ake bude dukk
Dyson
11/03/2025
Yadda Tattalin Tech Take Mika SF6 a Ring Main Units na Yanzu
Yadda Tattalin Tech Take Mika SF6 a Ring Main Units na Yanzu
Anfani na ring main (RMU) suna amfani da su a tattalin arziki na takardun gaba, tun daga haka za su kofin zuwa masu amfani kamar jama'a, makarantun kayan adawa, gwamnati, hanyoyi, da sauransu.A cikin substation na jama'a, RMU yana bayyana shugaban 12 kV, wanda ya zama 380 V ne a kan transformers. Anfani na low-voltage switchgear ke tattara energy mai tsawon kasa zuwa masu amfani. Don transformer na 1250 kVA a cikin jama'a, RMU na medium-voltage yana da muhimmanci ga konfigurashin na biyu na inco
James
11/03/2025
Me kadan da THD? Yadda Ya Haɗa da Gaskiya na Ƙarfin Kirkiyya & Farkon Aiki
Me kadan da THD? Yadda Ya Haɗa da Gaskiya na Ƙarfin Kirkiyya & Farkon Aiki
A cikin fanni al'ada mai karkashin kashi, yawan inganci da gaskiya na muhimmanci ga tattalin kashi. Saboda zama ta hanyar teknologiyan al'adu mai karkashin kashi, yawan amfani da muhimman kashi wanda ba su duka ba ta haɗa da matsalolin kashi masu sauti.Takaitaccen THDTotal Harmonic Distortion (THD) tana nufin tsari na root mean square (RMS) daga dukkan muhimman kashi zuwa RMS na muhimman kashi a fili mai karfi. Wannan shi ne abu mai girma, ana iya bayyana shi a baya a latsa. THD mai kadan ya nun
Encyclopedia
11/01/2025
Aika tambaya
Kwamfuta
Samun IEE Business Application
Yi amfani da IEE-Business app don samun abubuwan aikin, samun halayyin, haɗi da malamai, kuma kai tsauraran takaiddun kasoshin duka lokaci, duka wurin—dole bai karfin takamaltar hulɗin ku na alintakargida da kasuwanci.