What is an oil-immersed transformer?

Vziman
Vziman
Field: Manufacturing
China

Oil-Immersed Transformers: Overview, Features, and Applications

An oil-immersed transformer is a widely used type of power transformer that employs a liquid—typically insulating oil—as both an insulating and cooling medium.

Key Features of Oil-Immersed Transformers:

  • Insulating Oil: Insulating oil serves as the primary dielectric medium, electrically isolating the windings from the core and ground. With its high dielectric strength, it effectively prevents electrical breakdown between windings or between windings and the grounded core.

  • Cooling Mechanism: In addition to insulation, the oil provides efficient cooling through conduction and natural convection. The windings and core are fully immersed in the oil, which absorbs heat generated during operation. Due to its high thermal capacity, the oil helps transfer and dissipate heat, maintaining safe operating temperatures.

  • Pressure Relief Devices: As insulating oil expands when heated during operation, oil-immersed transformers are typically equipped with pressure relief devices. These safety mechanisms release excess oil vapor or pressure in the event of internal overpressure, protecting the tank from rupture or explosion.

  • Maintenance and Monitoring: Regular oil sampling and maintenance are essential to ensure the continued performance of the insulating oil. Key tests include dielectric strength, moisture content, and dissolved gas analysis (DGA). Degraded oil should be filtered, reconditioned, or replaced as needed. Transformers are also equipped with monitoring instruments such as oil level indicators, temperature gauges, and pressure sensors to continuously assess operational health.

  • Wide Range of Applications: Oil-immersed transformers are extensively used in power transmission and distribution systems, power plants, industrial facilities, and substations. They are available in a broad range of voltage and power ratings, providing stable, reliable, and efficient power supply under diverse operating conditions.

Advantages and Considerations:
Oil-immersed transformers offer excellent insulation performance, high short-circuit withstand capability, effective cooling, and long service life. However, they require more maintenance compared to dry-type transformers, have larger physical dimensions and weight, and pose potential environmental risks in the event of oil leakage. Therefore, careful evaluation of site conditions, environmental regulations, and operational requirements is essential when selecting an oil-immersed transformer for a specific application.

Give a tip and encourage the author!
Recommended
Complete Guide to Circuit Breaker Selection and Setting Calculation
Complete Guide to Circuit Breaker Selection and Setting Calculation
How to Select and Set Circuit Breakers1. Types of Circuit Breakers1.1 Air Circuit Breaker (ACB)Also known as a molded frame or universal circuit breaker, all components are mounted within an insulated metal frame. It is typically open-type, allowing easy replacement of contacts and parts, and can be equipped with various accessories. ACBs are commonly used as main power supply switches. Overcurrent trip units include electromagnetic, electronic, and intelligent types. They provide four-stage pro
Echo
10/28/2025
Low-Voltage Distribution Cabinet Maintenance Steps and Safety Guide
Low-Voltage Distribution Cabinet Maintenance Steps and Safety Guide
Maintenance Procedure for Low-Voltage Power Distribution FacilitiesLow-voltage power distr ibution facilities refer to the infrastructure that delivers electrical power from a power supply room to end-user equipment, typically including distribution cabinets, cables, and wiring. To ensure the normal operation of these facilities and guarantee user safety and power supply quality, regular maintenance and servicing are essential. This article provides a detailed introduction to the maintenance pro
Edwiin
10/28/2025
Low-Voltage Electrical Work Safety Preparation and Operation Guide
Low-Voltage Electrical Work Safety Preparation and Operation Guide
Low-Voltage Electrician Safety Operating Procedures1. Safety Preparation Before performing any low-voltage electrical work, personnel must wear approved protective equipment, including insulating gloves, insulating boots, and insulating workwear. Carefully inspect all tools and equipment for proper operation. Report any damage or malfunction immediately for repair or replacement. Ensure adequate ventilation at the worksite. Avoid prolonged work in confined spaces to prevent fire hazards or poiso
Echo
10/28/2025
How to Handle Common Faults in RMU and Transformer Substations?
How to Handle Common Faults in RMU and Transformer Substations?
1. Ring Main Unit (RMU) and Transformer SubstationThe ring main unit (RMU) and transformer substation is a critical terminal in a distribution ring network system. The operational status of this terminal is directly affected by the performance of the distribution ring network system. Therefore, this section discusses the advantages, system composition, and key characteristics of the distribution ring network.1.1 Advantages of RMU and Transformer SubstationDue to technological limitations, radial