Sheloshi polim shel miniaturi circuit breakers (MCB) yechol lehachpitz le'etgarot al pi tachlitam, siftei hatipa, hafatach ha'atzmi ve'itgarot meyuchadot. Lematara mitchutit shel etgarot sheloshi polim shel MCB:

1. Hachpitzah al pi tachlitam

3P (Shelosha Polim) MCB:

  • Tachlita: Nimtza b'mishkalim sheloshi polim she'ein lahem kav neutral (N). Nogea letachlitim k'v'davar motor sheloshi polim v'kailim teva'i she'ein tzricha lekav neutral.

  • Ma'ase: B'shituf chashalat o shum klali b'pol ehad, kol shlosha hapolim mitpatpatim b'yachad, misgir l'hatzat haklita shel haklita b'sikun.

3P+N (Shelosha Polim Plus Neutral) MCB:

  • Tachlita: Nimtza b'mishkalim sheloshi polim arba'a kavim shemazkir kav neutral. Nogea letachlitim k'v'davar mishkalim sheloshi polim u'fachim echad be'chad, k'mo batim noshim umishtachevim im taarich sheloshi polim.

  • Ma'ase: Haklita sheloshi polim notena shmirat chashalat u'shum klali, rak hakav neutral ein lo ta'asa mitpatpat. Aval b'shituf mitpatpat hakavim ha'atzmi, hakav neutral gam hu nifratzek l'hagshir mimeno sikun.

4P (Arba'a Polim) MCB:

  • Tachlita: Nimtza b'mishkalim sheloshi polim arba'a kavim shemazkir kav neutral. Nogea letachlitim she'mitbagshim shmirat chashalat shel hakav neutral, k'mo kailim delukati v'kailim refui'im.

  • Ma'ase: Arba'a polim MCB noten shmirat chashalat u'shum klali l'kol shlosha hapolim ve'hakav neutral. Im ye'ese chashalat b'pol ehad o hakav neutral, arba'a hapolim mitpatpatim b'yachad, misgir l'hatzat haklita shel haklita b'sikun.

2. Hachpitzah al pi siftei hatipa

Siftei hatipa shel MCB menatze'ach et zman hatipa bo nechoshavim yoter mi'hafatach hazeh. Etgarot tipa yekari'im melukachim:

  • B-Type: Mitpatpat b'3-5 pa'amim hafatach ha'atzmi. Nogea letachlitim purani'im u'kailim or hanacha, nimtza b'mishkalim noshim l'shimur kailim bayit u'l'shimur gviya.

  • C-Type: Mitpatpat b'5-10 pa'amim hafatach ha'atzmi. Nogea l'shimur kavim u'mishkalim im ma'agalim gedolim, k'mo kailim or v'motor. Zeh hu tipa ha'noga'a be'tachlitim teva'i'im u'mishtachevim.

  • D-Type: Mitpatpat b'10-20 pa'amim hafatach ha'atzmi. Nogea l'shimur kailim im ma'agalim adiri'im, k'mo transformatorim v'solenoidim. Tipa zu idealit lemishkalim im ma'agalim gadol.

  • K-Type: Mitpatpat b'8-12 pa'amim hafatach ha'atzmi. Nogea letachlitim induktivi'im v'mishkalim motorim im ma'agalim adiri'im. Nimtza l'shimur u'neged transformatorim, kavim yudape'i'im, v'motorim m'chashalat u'shum klali.

  • Z-Type (o A-Type): Mitpatpat b'2-3 pa'amim hafatach ha'atzmi. Eino nogea k'v'davar, tipa noga'a l'shimur semiconductors o tachlitim meyuchadot.

3. Hachpitzah al pi hafatach ha'atzmi

Hafatach ha'atzmi shel MCB sheloshi polim tipatych b'10A ad 63A o yoter, al pi tachlita. Etgarot hafatach ha'atzmi yekari'im melukachim:

  • 10A

  • 16A

  • 20A

  • 25A

  • 32A

  • 40A

  • 50A

  • 63A

4. Hachpitzah al pi tachlita

  • MCB Shel Kolel: Nogea l'shimur chashalat u'shum klali b'mishkalim noshim, mishtachevim u'teva'i'im.

  • Residual Current Circuit Breaker with Overcurrent Protection (RCBO): Yoter m'shimur chashalat u'shum klali, RCBO noten shmirat ma'agal shavi (ma'agal hitpashtut). Otam mitpatpatim b'chidush b'zman ma'agal hitpashtut over pa'amim set, misgir l'shimur gviya. Nogea letachlitim ruchi'im, matbakhim, hamamot, v'makomim asher shimur elektri'im hu mikre'i.

  • Current-Limiting MCB: Tipa zo mitgaberet al mispar ma'agal b'zman chashalat, metgaberet al hasaron l'hafatach u'kailim. Nogea letachlitim asher ma'agal chashalat yesh l'shimur chazak.

5. Hachpitzah al pi derech hashlama

  • DIN Rail Mounting: Derech hashlama ha'noga'a, nogea lekavim noshim u'teva'i'im. DIN rail-mounted MCBs yecholim lehashlim u'lefrot b'chidush, osim shimur u'chiluf easy.

  • Panel Mounting: Nogea letachlitim asher MCB tzrich l'hishtalem al panel, k'mo kavim noshim u'mishtachevim.

Itar

B'chirat MCB sheloshi polim tayar al pi tachlitim yekari'im, tipa shel masa, hafatach ha'atzmi, v'tachlitim shel shimur. Etgarot sheloshi polim shel MCB melukachim 3P, 3P+N, ve'4P, im siftei hatipa k'B, C, D, K, ve'Z. Hafatach ha'atzmi tipatych b'10A ad 63A. Yoter m'zeh, MCB yecholim l'bachor al pi tachlitim shel shimur ma'agal shavi, shimur ma'agal, o tachlitim meyuchadot.

תנו טיפ לעודדו את המחבר!

מומלץ

תאונות טרנספורטר ראשי ובעיות בפעולת גז קל
1. רישום תאונה (19 במרץ 2019)ב-19 במרץ 2019 בשעה 16:13 דיווח רקע הניטור על הפעלת גז קל של המתחנה הראשית מס' 3. בהתאם ל"תקנות תפעול מתחנות חשמל" (DL/T572-2010), בדקו אנשי הפעלה ותחזוקה (O&M) את המצב בשטח של המתחנה הראשית מס' 3.אימות בשטח: לוח הגנת המתחנה הראשית מס' 3 מסוג WBH דיווח על הפעלת גז קל של פאזה B בגוף המתחנה הראשית, ואיפוס לא היה יעיל. אנשי הפעלה ותחזוקה בדקו את מד הגז של פאזה B ואת קופסת דגימת הגז של המתחנה הראשית מס' 3, וביצעו מבחנים על זרם הארקה של הליבה והמקלות של גוף המתחנה הרא
02/05/2026
תקלות וטיפול בהם של כבישת חד-פאס בקווים של חלוקה ב-10kV
מאפיינים ומכשירי זיהוי של תקלה באדמה של פאזה אחת1. מאפייני תקלה באדמה של פאזה אחתאותות התראה מרכזיים:פעמון ההתראה מצלצל, ולוחית המנורה המתייחסת ל״תקלה באדמה בקטע אוטו-דינמי [X] קילו-וולט מספר [Y]״ מתבהקת. במערכות שבהן נקודת האפס מחוברת לאדמה דרך סליל פטרסן (סליל דיכוי קשת), גם המנורה המציינת את ״הפעלת סליל פטרסן״ מתבהקת.הוראות מדידת עמידות הבודדים:מתח הפאזה הפגועה יורד (במקרה של חיבור לא מלא לאדמה) או יורד לאפס (במקרה של חיבור מלא לאדמה).מתח שתי הפאזות האחרות עולה — מעל מתח הפאזה הנורמלי במקרה ש
01/30/2026
הפעלה של מודל חיבור נקודה ניטרלית עבור טרנספורמציות רשת חשמל 110kV~220kV
הסדר של אופני התחברות נקודה נייטרלית ל Boden בטרנספורמטורי רשת חשמל ב-110kV~220kV צריך לעמוד בדרישות הסיבולת החשמלית של נקודות הנייטרליות של הטרנספורמרים, וצריך גם להחזיק את המבנה של השדה האפסי של תחנות התאורה בערך קבוע, תוך שמירה על כך שהשדה האפסי המשולב בכל נקודת קצר Retorna לא יעלה על פי שלושה מהשדה החיובי המשולב.עבור טרנספורמנים ב-220kV וב-110kV בפרויקטים חדשים ושיפוצים טכנולוגיים, אופני ההתחברות שלהם של נקודות הנייטרליות צריכים לענות באופן מדויק על הדרישות הבאות:1. טרנספורמנים אוטומטייםנקוד
01/29/2026
למה תחנות מתח משתמשות באבנים, גרגרי חול, פצליים וסלע מרוסק?
למה תחנות מתח משתמשות באבני חצץ, גבישים וסיליקא? בתחנות מתח, ציוד כגון טרנספורמנים להספק ופיזור, קווי העברה, טרנספורמנים מתח, טרנספורמנים זרם ומשתני פסק כולם דורשים עיגול. מעבר לעיגול, נחקור כעת לעומק מדוע אבני חצץ וסיליקא בשימוש נפוץ בתחנות מתח. למרות שהם נראים רגילים, האבנים הללו משחקות תפקיד בטיחותי ופונקציונלי קריטי. בתכנון עיגול בתחנות מתח—ובמיוחד כאשר מיושמים מספר שיטות עיגול—נפרשות סיליקא או אבני חצץ על פני השטח מסיבות מפתחיות רבות. המטרה העיקרית של פרישה של אבני חצץ בחצר תחנת מתח היא להפ
01/29/2026
שלח הצעת מחיר
+86
לחץ כדי להעלות קובץ
הורדה
קבל את IEE Business אפליקציה коммерческая
השתמש באפליקציה IEE-Business כדי למצוא ציוד, לקבל פתרונות, להתחבר למומחי ולתת חלק בתיאום תעשייתי בכל זמן ובכל מקום – לתמיכה מלאה בפיתוח פרויקטי החשמל העסקים שלך