HRC Fuse (High Rupturing Capacity Fuse) and its Types

Edwiin
Edwiin
Field: Power switch
China

What is a High Rupturing Capacity (HRC) Fuse?

A High Rupturing Capacity (HRC) fuse is a type of protective device used in electrical systems to safeguard against overcurrent and short-circuit faults. It is engineered to safely interrupt high-magnitude fault currents without causing damage to surrounding equipment or itself. HRC fuses can reliably handle and clear large fault currents, typically up to 80 kA or higher, while eliminating risks of explosion or fire.

An HRC fuse contains a fuse element designed to safely carry short-circuit currents for a specified duration. If the fault is cleared within this period, the fuse remains intact; otherwise, the element melts and disconnects the circuit from the power supply, ensuring circuit safety.

While glass is a commonly used material for HRC fuse bodies, it is not the only option—other chemical compounds may be employed depending on specific requirements. The external enclosure of an HRC fuse is fully airtight to protect internal components from environmental factors. A key limitation of semi-enclosed HRC fuses is their lower and less predictable breaking capacity compared to fully enclosed types.

HRC Fuse with Tripping Device

When a fuse blows due to a fault condition, it triggers the tripping device, causing the circuit breaker to actuate. The fuse body is made of ceramic material, with metallic caps fixed at each end, connected by a series of silver fuse elements.

One end of the fuse is equipped with a plunger that, under fault conditions, strikes the tripping mechanism of the circuit breaker to prompt it to operate and interrupt the circuit. The plunger is connected to the other end of the cap via a fusible link and a tungsten wire.

When a fault occurs, the silver fuse element blows first, and the current is transferred to the tungsten wire. The plunger's stroke is designed such that it does not eject from the fuse body during fault conditions.

Advantages of HRC Fuse with Tripping Device

  • Single-Phase Fault Protection in Three-Phase Systems:When a single-phase fault occurs in a three-phase system, the plunger trips the circuit breaker, opening all three phases simultaneously to prevent unbalanced single-phase power supply.

  • Cost Reduction for Circuit Breakers:By allowing the fuse to handle the primary interruption of fault currents, the circuit breaker only needs to account for the effects of short circuits, enabling the use of less expensive breaker models.

  • Reduced Fuse Replacement Frequency:The tripped circuit breaker can handle small currents, eliminating the need to replace the fuse frequently (except in cases of high-current faults).

  • High Breaking Capacity Range:Low-voltage HRC fuses are available with breaking capacities ranging from 16,000A to 30,000A at 400V (some models extend to 80kA to 120kA), widely used for overload and short-circuit protection in low-voltage distribution systems.

Types of HRC Fuse

  • NH Fuse

  • Din Type

  • Blade Contact

NH Type

NH fuses provide overload and short-circuit protection for low and medium voltage systems, serving as backup protection for motor starters and other equipment against short circuits and overloads. These fuses are lightweight and compact in size.

Din Type

DIN-type fuses are available with a wide range of rated currents, suitable for various applications and featuring specific performance characteristics under different temperature conditions. They can be used across different voltage levels and are applicable for transformer protection even in the absence of low-voltage (LV) secondary or backup protection. They exhibit excellent clearing capability for low overcurrent conditions and ideal short-circuit performance. DIN fuses are widely used in air and gas-insulated switchgear, mining, transformers, and feeder sectionalizing.

Blade Type

Also known as spade or plug-in fuses, blade-type fuses feature a plastic body with two metal caps for socket installation. Primarily used in automotive wiring for short-circuit protection, they are lightweight and have a low cutoff current. They also serve as backup protection for motors against short circuits. Available in various sizes, shapes, and current ratings (printed on the top), these fuses offer flexibility for different applications.

Advantages & Disadvantages
Advantages

  • Clears both high and low fault currents

  • Does not degrade with age

  • Operates at high speed

  • Provides reliable protective discrimination

  • Requires no maintenance

  • More cost-effective than other circuit-interrupting devices with the same rating

  • Ensures consistent performance

  • Fast fusing operation without noise or smoke

Disadvantages

  • Requires replacement after each operation

  • Heat generated by the arc may affect adjacent switches

Applications

  • Transformer Protection: Commonly used to safeguard transformers from overcurrent and short-circuit faults

  • Motor Protection: Serves as backup protection for motors against overloads and short circuits

  • Automotive Systems: Applied in automotive electrical systems to protect wiring and components

  • Motor Stators: Specifically designed for electrical fault protection in motor stators

  • Backup Protection: Functions as backup protection for various electrical equipment and systems

  • Low-Voltage Distribution Systems: Prevents and mitigates fault impacts in low-voltage networks

  • Industrial Applications: Used in diverse industrial settings to protect electrical circuits and equipment

  • Feeder Sectionalizing: Ensures reliability and safety in electrical distribution through feeder sectionalization

  • Air and Gas-Insulated Switchgear: Protects components within air and gas-insulated switchgear

  • Mining Operations: Provides circuit protection in mining environments

Final Thoughts

After evaluating the advantages and disadvantages of HRC fuses in low-voltage installations, their ease of replacement, high-speed short-circuit/overcurrent protection, and contribution to industrial power distribution stability and semiconductor protection are evident. In low-voltage systems, fuses and circuit breakers complement each other: HRC fuses can provide backup protection to circuit breakers with high breaking capacity.

Give a tip and encourage the author!
Recommended
Why You Can't Remove Siemens GIS Bushing Cover for PD Testing
Why You Can't Remove Siemens GIS Bushing Cover for PD Testing
As the title suggests, when performing live partial discharge (PD) testing on Siemens GIS using the UHF method—specifically by accessing the signal through the metal flange of the bushing insulator—you must not directly remove the metal cover on the bushing insulator.Why?You won’t realize the danger until you try. Once removed, the GIS will leak SF₆ gas while energized! Enough talk—let’s go straight to the diagrams.As shown in Figure 1, the small aluminum cover inside the red box is typically th
James
10/24/2025
Why Cement Sealing Is Banned for GIS Wall Penetrations?
Why Cement Sealing Is Banned for GIS Wall Penetrations?
Indoor GIS equipment typically involves wall-penetrating installations, except in cases with cable in/out connections. In most cases, the main or branch bus duct extends from indoors through a wall to the outdoor side, where it connects to porcelain or composite bushings for overhead line connections. The gap between the wall opening and the GIS bus enclosure, however, is prone to water and air leakage and therefore usually requires sealing. This article discusses why cement-based sealing is not
Echo
10/24/2025
How Acoustic Imaging Locates GIS Defects
How Acoustic Imaging Locates GIS Defects
In recent years, acoustic imaging technology for GIS defect detection has developed rapidly. This technology enables intuitive sound source localization, helping operation and maintenance personnel focus on the exact location of GIS defects, thereby improving the efficiency of defect analysis and resolution.Sound source localization is only the first step. It would be even more ideal if common GIS defect types could be automatically identified using artificial intelligence (AI), along with intel
Edwiin
10/24/2025
On-Line Testing for Surge Arresters Below 110kV: Safe and Efficient
On-Line Testing for Surge Arresters Below 110kV: Safe and Efficient
An On-Line Testing Method for Surge Arresters at 110kV and BelowIn power systems, surge arresters are critical components that protect equipment from lightning overvoltage. For installations at 110kV and below—such as 35kV or 10kV substations—an on-line testing method effectively avoids the economic losses associated with power outages. The core of this method lies in using online monitoring technology to evaluate arrester performance without interrupting system operation.The test principle is b
Oliver Watts
10/23/2025
Related Products
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.