Three Phase Wattmeter

03/15/2025

Three Phase Wattmeter

Definition: A Three - Phase Wattmeter is an instrument employed for measuring the power in a three - phase circuit. In a three - phase Wattmeter, two individual Wattmeter elements are integrated within a single housing. Their moving coils are positioned on the same spindle.

Three - Phase Wattmeter Structure

A three - phase wattmeter consists of two elements. Each single element is a combination of a pressure coil and a current coil. In the wattmeter, the current coils are regarded as fixed coils, while the pressure coils serve as the moving coils.

Working Principle of the Three - Phase Wattmeter

The three - phase wattmeter operates based on the principle that when a current - carrying conductor is placed in a magnetic field, a torque is generated. When the power being measured passes through the moving coils, a torque is developed on these coils. Torque is a form of mechanical force whose effect can cause an object to deflect in a circular motion.

In a three - phase wattmeter, torque is developed on both elements. The value of the torque on each element is proportional to the power passing through it. The total torque on the three - phase wattmeter is the sum of the torques on the individual wattmeter elements.

Let's understand this with the help of mathematical expressions.

Suppose the deflecting torque developed on coil 1 is (D1) and the power passing through that element is \(P_1\). Similarly, the torque developed on coil 2 is (D2) and the power passing through it is (P2).

01.jpg

The total torque develops in the coil is expressed as

02.jpg

Connections of Three - Phase Wattmeter

Consider a circuit with two wattmeters. The current coils of both wattmeters are connected across any two phases, for example, the R and Y phases. The pressure coils of both wattmeters are connected across the third phase, namely the B phase.

Influence of Mutual Interference and Mitigation Measures

The mutual interference between the elements of a three - phase wattmeter can affect its accuracy. Mutual interference is a phenomenon where the magnetic fields of the two elements interact with each other. In a three - phase wattmeter, a laminated iron shield is placed between the elements. This iron shield effectively reduces the mutual influence between the elements, thereby enhancing the accuracy of the wattmeter's measurements.

03.jpg

The mutual effect can be compensated for by employing the Weston method. In the Weston method, adjustable resistors are utilized. These resistors counteract the mutual interference that takes place between the elements of a three - phase wattmeter.


The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
08/30/2025
Transformer Connection Sections
Transformer Connection Sections
Transformer Connection DesignationsThe transformer connection designation indicates the winding connection method and the phase relationship between the line voltages of the primary and secondary windings. It consists of two parts: letters and a number. The letters on the left denote the connection configurations of the high-voltage and low-voltage windings, while the number on the right is an integer from 0 to 11.This number represents the phase shift of the low-voltage winding's line voltage r
08/15/2025
Automatic Reclosing Scheme in Transmission Systems
Automatic Reclosing Scheme in Transmission Systems
Automatic Reclosing Scheme for Transmission SystemsThe automatic reclosing system is a series-connected network designed to reduce operating costs and enhance network reliability. Extra-high voltage (EHV) transmission lines are used to transmit large amounts of power, on the order of thousands of megawatts (MW), and therefore should not be interrupted at all costs. Although faults on these overhead lines are common, the power transmitted through them should not be interrupted for long periods du
08/07/2025
Transformer operation and maintenance
Transformer operation and maintenance
Transformer Operating TemperatureDuring operation, transformers generate copper losses and iron losses, both of which are converted into heat, causing the transformer’s temperature to rise. Most transformers in China use Class A insulation. Due to heat transfer characteristics, significant temperature differences exist between different components during operation: winding temperature is the highest, followed by the core, and then the temperature of the insulating oil (with upper-layer oil being
07/31/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!