Traction Rectifier Transformers

Rated capacity: 800 to 4400 kVA; Voltage class: 10 kV and 35 kV; Rectifier pulse number: 12-pulse and 24-pulse. Compared with 12-pulse rectifier circuits, 24-pulse rectifier circuits can reduce the harmonic pollution of the power grid by 50%, and no filtering equipment is needed at this location. It is suitable for power supply systems of urban subways and rail transit.

Excitation Rectifier Transformers

Rated capacity: 315 to 3000 × 3 kVA; Voltage class: 10 kV, 13.8 kV, 15.75 kV, 20 kV and 22 kV. It is usually designed with a single-phase structure, high-voltage phase-isolated enclosed busbar input and shielding between high-voltage coils. It is suitable for static excitation systems of hydropower plants and thermal power plants.

General-Purpose Rectifier Transformers

Rated capacity: 315 to 4000 kVA; Voltage class: 10 kV and 35 kV. It is suitable for rectifier systems of general industrial and mining enterprises.

H-Bridge Rectifier Transformers

Rated capacity: 315 to 2500 kVA; Voltage class: 3 kV and 6 kV. Each phase can be composed of 3 to 9 windings, which can be combined in pairs through phase-shifting connection to form an H-bridge rectifier. It is suitable for AC-DC variable frequency power supply systems of motors.

Three-Phase Five-Leg Rectifier Transformers

Rated capacity: 30 to 2500 kVA; Voltage class: 10 kV and 35 kV. It is used in double-delta rectifier circuits, which can eliminate balance reactors and reduce the impact of voltage-stabilizing current. It also reduces the transportation height. It is suitable for transformers with limited installation space or transformers used in delta rectifier systems.

Metallurgical Electric Furnace Transformers

Rated current: Less than 20,000 A; Voltage class: 10 kV and 35 kV; Equipped with an off-circuit tap changer. It is suitable for high-current electric furnace power supply systems in the metallurgical industry.

Marine and Offshore Platform Transformers

Rated capacity: 30 to 10,000 kVA; Voltage class: 0.38 kV and 35 kV; Certified by China Classification Society (CCS) and holds the CCS Type Approval Certificate for Marine Products. It is suitable for power supply systems on ships and offshore drilling platforms.

Give a tip and encourage the author!
Recommended
Why Regular Transformer Maintenance Matters: 5 Serious Consequences of Neglecting It
I. Allowable TemperatureWhen a transformer is in operation, its windings and iron core generate copper loss and iron loss. These losses are converted into heat energy, causing the temperature of the transformer's iron core and windings to rise. If the temperature exceeds the allowable value for a long time, the insulation will gradually lose its mechanical elasticity and age.The temperature of each part of the transformer during operation is different: the winding temperature is the highest, fol
Rockwell
09/12/2025
How to Implement Condition-Based Maintenance for Power Transformers? A Complete 4-Step Process Analysis
1. Definition of Condition-Based MaintenanceCondition-based maintenance refers to a maintenance method where decisions on whether and how to perform maintenance are determined based on the real-time operating status and health condition of equipment. It has no fixed maintenance methods or schedules. The prerequisite for condition-based maintenance is the establishment of equipment parameters and the comprehensive analysis of various operational information of the equipment, so as to make reasona
Noah
09/12/2025
SG10 Series Transformer Overload Protection Solution | Prevent Overheating and Damage, View Now
Operating Conditions in National Standard GB 6450-1986Ambient temperature: Maximum ambient temperature: +40°C Daily average maximum temperature: +30°C Annual average maximum temperature: +20°C Minimum temperature: -30°C (outdoor); -5°C (indoor) Horizontal axis: Product load; Vertical axis: Average coil temperature rise in Kelvin (note: not in Celsius).For Class H insulation products, the long-term temperature resistance of insulation materials is stipulated by the state as 180°C. However, the in
Rockwell
09/12/2025
High harmonics? Your transformer may be overheating and aging fast.
This report is based on the analysis of one-day power quality monitoring data of your company's distribution system. The data shows that there is significant three-phase current harmonic distortion in the system (with a high total harmonic distortion of current, THDi). In accordance with international standards (IEC/IEEE), harmonic currents at this level have posed substantial risks to the safe, reliable, and economical operation of the power supply transformer, mainly manifested in additional h
Leon
09/12/2025
Related Products
Seed Inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.