Komponants na Sistem ɗin Ingantaccen Karkashin Rijiyar Solar

Electrical4u
Electrical4u
فیلڈ: Karkashin Kuliya da Dukkana
0
China

WechatIMG1800.jpeg

Solar Panels

An karkashin cikin sashe da yake shirya tsohon rarrabe na biyaya shine solar panel. Akwai abubuwa daban-daban da suka fi sune a kasuwanci. Solar panels suna nufin photovoltaic solar panels. Solar panel ko solar module ya nuna array ta solar cells da aka fara da zama.

Farkon potential difference da ya samun a solar cell shine kusan mita 0.5 volt, saboda haka an bukata tsari masu solar cells da za a fara don tabbatar da 14 zuwa 18 volts don kara battery da takalma 12 volts. Solar panels suna fara da zama solar array. Tsarin solar panels suna fara da zama both in parallel and series don tabbatar da current da voltage masu yawan sama.

solar electric generation system
parallel solar array
series solar array

Batteries

A cikin sashe da yake shirya tsohon rarrabe na biyaya, modules masu solar suna fara da inverter, kuma ba su fara da load ba. Power da aka samu daga solar panels ba ce mai zurfi, amma yana canza da keke mai zurfi. Wannan shine dalilin da modules masu solar ko panels ba su yi wa electrical equipment directly. Amma su yi wa inverter wanda output ita ce synchronized with external grid supply.

Inverter takes care of the voltage level and frequency of the output power from the solar system it always maintains it with that of grid power level. As we get power from both solar panels and external grid power supply system, the voltage level and quality of power remain constant. As the stand-alone or grid fallback system is not connected with grid any variation of power level in the system can directly affects the performance of the electrical equipment fed from it.

Saboda haka akwai kyau da ya gaba da yin da take care of the voltage level and power supply rate of the system. A battery bank connected parallel to this system takes care of that. Here the battery is charged by solar electricity and this battery then feeds a load directly or through an inverter. In this way variation of power quality due to variation of sunlight intensity can be avoided in solar power system instead an uninterrupted uniform power supply is maintained.

Normally Deep cycle lead acid batteries are used for this purpose. These batteries are typically designed to make capable of several charging and discharging during service. The battery sets available in the market are generally of either 6 volt or 12 volts. Hence number of such batteries can be connected in both series as well as parallel to get higher voltage and current rating of the battery system.

Controller

This is not desirable to overcharge and under discharge a lead acid battery. Both overcharging and under discharging can badly damage the battery system. To avoid these both situations a controller is required to attach with the system to maintain flow of current to and fro the batteries.

Inverter

It is obvious that the electricity produced in a solar panel is DC. Electricity we get from the grid supply is AC. So for running common equipment from grid as well as solar system, it is required to install an inverter to convert DC of solar system to AC of same level as grid supply.

In off grid system the inverter is directly connected across the battery terminals so that DC coming from the batteries is first converted to AC then fed to the equipment. In grid tie system the solar panel is directly connected to inverter and this inverter then feeds the grid with same voltage and frequency power.

solar inverter

In modern grid tie system, each solar module is connected to grid through individual micro-inverter to achieve high voltage alternating current from each individual solar panel.
individual solar inverter

Components of Stand Alone Solar System

Stand Alone or Off Grid Solar Power Station
A basic block diagram of a stand-alone solar electric system is show above. Here the electric power produced in the solar panel is first supplied to the solar controller which in turn charges the battery bank or supplies directly to the low voltage DC equipments such as laptops and LED lighting system. Normally the battery is fed from solar controller but it can also feed the solar controller when there is insufficient supply of power from solar panel.

In this way the supply is continued uniformly to the low voltage equipments which are directly connected to the solar controller. In this scheme the battery bank terminals are also connected across an inverter. The inverter converts the stored DC power of the battery bank to high voltage AC for running larger electrical equipments such as washing machines, larger televisions and kitchen appliances etc.

Components of Grid Tie Solar System

Grid tie solar systems are of two types one with single macro central inverter and other with multiple micro inverters. In the former type of solar system, the solar panels as well as grid supply are connected to a common central inverter called grid tie inverter as shown below.

grid-tie system with single central micro-inverter
The inverter here converts the DC of the solar panel to grid level AC and then feeds to the grid as well as the consumer’s distribution panel depending upon the instantaneous demand of the systems. Here grid-tie inverter also monitors the power being supplied from the grid.


If it finds any power cut in the grid, it actuates switching system of the solar system to disconnect it from the grid to ensure no solar electricity can be fed back to the grid during power cut. There is on energy meter connected in the main grid supply line to record the energy export to the grid and energy import from the grid.

As we already told there is another type of grid-tie system where multiple micro-inverters are used. Here one micro inverter is connected for each individual solar module. The basic block diagram of this system is very similar to previous one except the micro inverters are connected together to produce desired high AC voltage.
grid-tie system with multiple micro-inverters
In previous case the low direct voltage of solar panels is first converted to alternating voltage then it is transformed to high alternating voltage by transformation action in the inverter itself but in this case the individual alternating output voltage of micro inverters are added together to produce high alternating voltage.

Statement: Respect the original, good articles worth sharing, if there is infringement

Ba da kyau kuma kara mai rubutu!
Makarantarƙi:
Tambayar Da Yawanci
Istifararsa Dukkantar THD Don Tarihin Kirkiro na Sisinta Tsakiya
Istifararsa Dukkantar THD Don Tarihin Kirkiro na Sisinta Tsakiya
Toleransi Eror dari Distorsi Harmonik Total (THD): Analisis Komprehensif Berdasarkan Skenario Aplikasi, Ketepatan Alat, dan Standar IndustriRentang toleransi eror untuk Distorsi Harmonik Total (THD) harus dievaluasi berdasarkan konteks aplikasi spesifik, ketepatan alat pengukuran, dan standar industri yang berlaku. Berikut ini adalah analisis mendalam dari indikator kinerja utama dalam sistem tenaga, peralatan industri, dan aplikasi pengukuran umum.1. Standar Eror Harmonik dalam Sistem Tenaga1.1
Edwiin
11/03/2025
Kabilarin Yakin Da Kasa a 24kV Eco-Friendly RMUs: Yadda Da Kyau & Yadda A Yi
Kabilarin Yakin Da Kasa a 24kV Eco-Friendly RMUs: Yadda Da Kyau & Yadda A Yi
An samun hanyar inganci da kuma hanyar ingancin hawa mai sauya shi ne abu na gurbin 24 kV ring main units. Tare da hanyar ingancin hawa mai sauya shi, za a iya lalace da ci gaban inganci ko kuma cikakken fase da kyau zuwa rayuwar. Tabbacin pole ya zama yadda ake taimaka da hanyar ingancin hawa mai sauya shi da kuma magana da vacuum interrupter da kuma mafi girman adadin adadin.Don 24 kV outgoing busbar, idan an rike fase spacing a 110 mm, maka vulcanizing wajen busbar ya zama yadda ake bude dukk
Dyson
11/03/2025
Yadda Tattalin Tech Take Mika SF6 a Ring Main Units na Yanzu
Yadda Tattalin Tech Take Mika SF6 a Ring Main Units na Yanzu
Anfani na ring main (RMU) suna amfani da su a tattalin arziki na takardun gaba, tun daga haka za su kofin zuwa masu amfani kamar jama'a, makarantun kayan adawa, gwamnati, hanyoyi, da sauransu.A cikin substation na jama'a, RMU yana bayyana shugaban 12 kV, wanda ya zama 380 V ne a kan transformers. Anfani na low-voltage switchgear ke tattara energy mai tsawon kasa zuwa masu amfani. Don transformer na 1250 kVA a cikin jama'a, RMU na medium-voltage yana da muhimmanci ga konfigurashin na biyu na inco
James
11/03/2025
Me kadan da THD? Yadda Ya Haɗa da Gaskiya na Ƙarfin Kirkiyya & Farkon Aiki
Me kadan da THD? Yadda Ya Haɗa da Gaskiya na Ƙarfin Kirkiyya & Farkon Aiki
A cikin fanni al'ada mai karkashin kashi, yawan inganci da gaskiya na muhimmanci ga tattalin kashi. Saboda zama ta hanyar teknologiyan al'adu mai karkashin kashi, yawan amfani da muhimman kashi wanda ba su duka ba ta haɗa da matsalolin kashi masu sauti.Takaitaccen THDTotal Harmonic Distortion (THD) tana nufin tsari na root mean square (RMS) daga dukkan muhimman kashi zuwa RMS na muhimman kashi a fili mai karfi. Wannan shi ne abu mai girma, ana iya bayyana shi a baya a latsa. THD mai kadan ya nun
Encyclopedia
11/01/2025
Aika tambaya
Kwamfuta
Samun IEE Business Application
Yi amfani da IEE-Business app don samun abubuwan aikin, samun halayyin, haɗi da malamai, kuma kai tsauraran takaiddun kasoshin duka lokaci, duka wurin—dole bai karfin takamaltar hulɗin ku na alintakargida da kasuwanci.