Fault of Electric Cable

Electrical4u
Electrical4u
Field: Basic Electrical
0
China

Electric Cable Faults

It can be of three (3) types of electric cable faults found. They are

  • There may be a short circuit between two conductors,

  • There may be earth fault, i.e., fault between conductor and ground,

  • There may be open circuit caused due to disconnection of the conductor.

There can be more than one of the faults at a time.
The primary cause of the 1st and 2nd fault is due to damage of insulation caused by water, moisture or other reason. Due to the defect in the armour, plumbing or the lubricant compound gets out due to excess heat, insulation of the cable can get damaged.

Moreover, due to ageing, the insulation can get damaged. Normally the lifespan of a cable is about 40 to 50 years. PVC cable gets damaged due to wrong handling. If the compound elements decrease in the terminal box, the fault in cable occurs. If we do not join or terminate the cable properly, there may be an open circuit fault. Due to depression in the soil, there can be a stretch in the joint which may lead to an open circuit fault. Moreover, if we do not fit the clamps properly below the terminal box, an open circuit fault may occur. Apart from these, all reasons for the short circuit may also lead to an open circuit fault.fault of electric cable

Detection of Fault in Cable

If there is any fault in the cable, through megger test, it is to be detected that, what types of the fault have occurred. If required the fault resistance should get measured by multimeter. After the fault is detected, one should first examine the entire terminal box. In most of the occasion, you will see that the fault is in the terminal box. If there is indoor and outdoor box in the cable, then we check the outdoor box first, then the indoor box. If we do not find any fault in the terminal box, then we have to locate the place where the cable got a fault. If there is joint in the cable one should inspect the same, too.

If fault resistance is found more then where the fault occurs, one should burn the insulation “Fault Burning” and can decrease the resistance and after that Murray Loop Test can be done. Normally V.C. high voltage pressure testing set is used in fault burning work. If there is faults in more than one core then the core which is having less resistance that is to be burnt. The burning depends upon the fault and conditions of the cable. Normally the rate of resistance comes down within 15 to 20 minute.

If there is a fault in the cable, we should detect the type of fault with a megger. We normally measure earth resistance of each core. If there is a short between the core and the earth, the I.R. of such core will show ‘ZERO” or very less in megger meter. If we do not find continuity in any core between two ends, there is an open circuit on such core. If there is no continuity in all the three cores, we can understand that the entire three cores are open circuited.
After detecting the fault, we have to repair the cable.

Localisation of Cable Fault

There are different methods to detect the location of the fault in the cable. We adopt different methods in different situations. Some of the methods are herein below:

  • Murray Loop Test

  • Voltage Drop Test.

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Give a tip and encourage the author!
Recommended
What are the advantages of using a common grounding system in power distribution, and what precautions should be taken?
What are the advantages of using a common grounding system in power distribution, and what precautions should be taken?
What Is Common Grounding?Common grounding refers to the practice where a system’s functional (working) grounding, equipment protective grounding, and lightning protection grounding share a single grounding electrode system. Alternatively, it may mean that grounding conductors from multiple electrical devices are connected together and linked to one or more common grounding electrodes.1. Advantages of Common Grounding Simpler system with fewer grounding conductors, making maintenance and inspecti
Echo
11/05/2025
What Are the Top 10 Taboos and Precautions in the Installation of Distribution Boards and Cabinets?
What Are the Top 10 Taboos and Precautions in the Installation of Distribution Boards and Cabinets?
There are many taboos and problematic practices in the installation of distribution boards and cabinets that must be noted. Especially in certain areas, improper operations during installation may lead to serious consequences. For cases where the precautions were not followed, some corrective measures are also provided here to remedy previous mistakes. Let’s follow along and take a look at common installation taboos from manufacturers regarding distribution boxes and cabinets!1. Taboo: Lighting
James
11/04/2025
What Are the Factors Influencing the Impact of Lightning on 10kV Distribution Lines?
What Are the Factors Influencing the Impact of Lightning on 10kV Distribution Lines?
1. Induced Lightning OvervoltageInduced lightning overvoltage refers to the transient overvoltage generated on overhead distribution lines due to nearby lightning discharges, even when the line is not directly struck. When a lightning flash occurs in the vicinity, it induces a large amount of charge on the conductors—opposite in polarity to the charge in the thundercloud.Statistical data shows that lightning-related faults caused by induced overvoltages account for approximately 90% of total fau
Echo
11/03/2025
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
Related Products
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.