Quid est GIS?

Encyclopedia
Campus: Encyclopaedia
0
China

Definitio apparati GIS


GIS est abbreviatura pro Gas Insulated Switchgear, quod saepe vertitur ut apparatus combinatus totaliter clausus insulatus gaseo, solito utendo SF6 gas ut medium insulationis. Includit circuit breaker (CB), disjunctorem (DS), commutatorem terre (ES, FES), BUS (BUS), transformator currentis (CT), transformator tensionis (VT), parafulmen (LA) et alia componenta altae tensionis. Praesentia producta apparatorum GIS iam operantur in ambitu tensionis 72.5 kV ~1200 kV.


53c21faa8c33374d7f652ba8eda068f8.jpeg


Characteristica apparatorum GIS


Propter excellentem potentiam insulationis, extinguendi arcum et stabilitatem SF6 gas, apparatu GIS habent praestantias parvam superficiem, fortem potentiam extinguendi arcum et altam fiduciam. Tamen potentia insulationis SF6 gas valde afficitur uniformitate campi electrici, et anormalitates insulationis facile oriuntur ubi sunt apices vel corpora aliena in GIS.



Apparatus GIS adoptat structuram totaliter clausam, quae adferit praestantias componentium internorum liberorum ab interventu ambientis, longum cyclum revisionis, minus laboris maintenance, parvam interference electromagneticam, simulque existunt problemata sicut complexitas unius opusculi revisionis et relativus defectus instrumentorum detectionis, et cum structura clausa erodatur ab ambiente externo, adferet series problematum sicut imbibitio aquae et effluvia aeris.


5436d1ae80a97c066073f10c97a2321f.jpeg


Structura interna apparatorum GIS


Circuitus conductoris GIS componitur ex pluribus componentibus. Secundum modum operationis, potest generaliter dividi in: contactum fixum (contactus electricus fixus per fastigia sicut scrupula vocatur contactus fixus, et contactus fixus non movetur relativo in processu operationis. Sicut conexus inter contactum et basin, etc.), contactum separabile (contactus electricus qui potest separari in processu operationis etiam vocatur contactus separabilis), contactum glissans et rotans (in processu operationis, contactus possunt glissare vel rotare invicem, sed contactus electricus qui non potest separari vocatur contactus glissans et rotans. Contactus medius switchgear usus est huiusmodi contactus electricus).


48f61236d3eee77a6c5f7ee32d981ac9.jpeg


Applicatio


Substation GIS


Hexafluorid sulfuris clausus apparatus combinationis electrici, internationaliter notus ut "Gas insulated Switchgear" (Gas lnsulated Switchgear) breviter GIS, quod substationem praeter transformator in primario equipment, includit circuit breaker, disjunctorem, commutatorem terre, transformator tensionis, transformator currentis, parafulmen, bus, terminalem cabli, bushing inlet et outlet line, organic design optimizatus in unum. Praeter GIS, existit HGIS, designatus pro asperioribus ambientibus, propter relativum GIS pauciora bus, variabilitas pressionis bus, parafulmen et alia equipment, specialiter bus, usus magis flexibilis.


e215339f242cf555282f5ea797f791b5.jpeg


Praestantia


  • Miniaturization: SF6 gas cum excellenti potentia insulationis utitur ut medium insulationis et extinguendi arcum, quod valde minuit volumen substationis.


  • Alta fiducia: partes viventes omnes clauduntur in inert SF6 gas, quod augit fiduciam substationis.


  • Bona securitas: pars viva clauditur in metallica vestimenta terrae, ita nullum periculum electricitatis. SF6 gas est gas non comburens, ita nullum periculum incendii.


  • Eliminatio effectuum adversorum in externe: pars viva clauditur cum metallica vestimenta, protegens contra electromagneticum et staticum, parvum sonum, fortis potentia anti-radio-interference.


  • Brevis periodus installationis: realizatio miniaturizationis facit totum machinale assemblatum et testatum in fabula, potest transmitti ad locum in forma unitatum vel intervallorum, sic potest breviare periodum installationis in loco, simulque augmentare fiduciam.



Facilis maintenance, brevis tempus maintenance: propter rationabilem dispositionem structurae et systema extinguendi arcum, valde augit vitam producti, ita longus est cyclus maintenance, parvum est labor maintenance, et propter miniaturizationem, parva est distantiola a terra, conveniens pro quotidiana maintenance.


Sortes


GIS dividitur in typum exteriorum et interiorum secundum locum installationis.


f8e4cb2968879abc709020ea890e418b.jpeg


GIS generaliter dividitur in duas formas: singulus phase singulus cylinder et tres phase communis cylinder. Nivelem tensionis 110kV et bus bar posse fieri in formam tres phase communis cylinder, et singulus phase singulus cylinder utitur pro 220kV et superiore.


7814f662-25a9-486d-9ca4-9c3d21cf457b.jpg

Principium operationis


  • In casibus normalibus, circuit breaker et disjunctorem apparatorum GIS principale operantur in area remota. Circuit breaker et disjunctorem activantur in area remota/locali ad focus in loco remoto.


  • Commutator terre apparatorum GIS potest operari solum in area locali. Quando operaris commutatorem terre, commuta commutatorem terre ad area remotam/localis.


  • In ullo casu, solum operatio programmatica potest fieri, "interlock release switch" in armario controlis fili must esse in positione "interlock", et sua clavis unlock et clavis computer anti-misunderstanding lock sigillantur simul et utuntur secundum idem provisiones.



Requisitus operationis


  • Camera SF6 interior frequenter introducta a operatoribus: ventilatio saltem semel per shift pro 15 minutis, volumen aeris mutandi debet esse maius quam 3-5 vices volumen aeris, et exitus aeris debet instaurari in parte inferiore camerae; Loci equipmenti non frequenter introducti a operatoribus: ventilare pro 15 minutis ante introitum.


  • Pro partibus facile tactis a operatoribus et maintenanciis, sub normalibus conditionibus, voltage induxit in shell et frame non debet excedere 36V.


  • Augmentum temperaturae: pars facile tacta a operatoribus non debet excedere 30K; Pars facile tacta a operatoribus sed non tacta in operatione non debet excedere 40K; Partes individuae non facile accessibiles a operatoribus non debent excedere 65K.


  • Inspection apparatorum SF6, saltem semel per diem, inspection substationis sine custode secundum regulas. In inspectione, principale inspectio est ut videat appearance, si equipment anormale est, et faciat recordationem.


Donum da et auctorem hortare

Suggestus

Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
01/30/2026
Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
01/29/2026
Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
01/29/2026
HECI GCB for Generators – Cepus SF₆ Circuit Breaker
1. Definitio et Functio1.1 Munus Interruptoris Circuiti GeneratorisInterruptor Circuitus Generatoris (GCB) est punctum disiunctionis controllabile situatum inter generator et transformator incrementalis, servans ut interficium inter generator et rete electricitatis. Principales eius functiones includunt isolationem defectuum lateris generatoris et facilitationem controlis operationis durante synchronizatione generatoris et connectione ad rete. Principium operativum GCB non differt significanter
01/06/2026
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum