Types of Transformer Insulation Accessories

Transformer insulation accessories are key components that ensure the safe operation of transformers. They not only provide necessary insulation performance but also ensure the stability and reliability of transformers under various operating conditions. Here are some main types of transformer insulation accessories:

Inner Insulation Fittings

The internal insulation accessories are located inside the transformer tank and include the following types:

  • Bushing Insulation: Bushing insulation serves as a passage connecting the internal windings of a transformer to external lines, while also providing necessary insulation properties.

  • Winding Insulation: Winding insulation includes insulation between windings, insulation between windings and the iron core, etc., to ensure that the windings do not experience breakdown under high voltage.

  • Lead and Tap Switch Insulation: These insulations are used to protect leads and tap switches from damage caused by arcs or overvoltages.

Outdoor Insulation Accessories

The external insulation accessories are located outside the transformer tank and include the following types:

  • Air Insulation: This is the simplest form of external insulation, utilizing air as the insulating medium, and is typically used for low-voltage equipment.

  • Insulating Sleeves: In addition to internal insulation, insulating sleeves can also serve as part of the external insulation, especially in high-voltage transformers where they are required to withstand higher voltages.

Other Insulating Fittings

In addition to the aforementioned internal insulation and external insulation accessories, there are some other types of insulation accessories, such as:

  • Insulating Oil: Insulating oil not only provides insulation but also serves as a coolant and an arc extinguishing agent.

  • Insulating Paperboard and Pads: These materials are used for insulation between windings to ensure that the windings do not experience breakdown at high voltages.

To sum up, there are numerous types of transformer insulation accessories, each with its specific function and application scenarios. Choosing the appropriate insulation accessories is crucial in the design and maintenance process of transformers to ensure their safe and reliable operation.

Give a tip and encourage the author!
Recommended
How to Identify Internal Faults in a Transformer?
How to Identify Internal Faults in a Transformer?
Measure DC resistance: Use a bridge to measure the DC resistance of each high- and low-voltage winding. Check whether the resistance values among phases are balanced and consistent with the manufacturer’s original data. If phase resistance cannot be measured directly, line resistance may be measured instead. The DC resistance values can indicate whether the windings are intact, whether there are short circuits or open circuits, and whether the contact resistance of the tap changer is normal. If
Felix Spark
11/04/2025
What are the requirements for inspecting and maintaining a transformer's no-load tap changer?
What are the requirements for inspecting and maintaining a transformer's no-load tap changer?
The tap changer operating handle shall be equipped with a protective cover. The flange at the handle shall be well sealed with no oil leakage. Locking screws shall securely fasten both the handle and the drive mechanism, and the handle rotation shall be smooth without binding. The position indicator on the handle shall be clear, accurate, and consistent with the tap voltage regulation range of the winding. Limit stops shall be provided at both extreme positions. The insulating cylinder of the t
Leon
11/04/2025
How to Overhaul a Transformer Conservator (Oil Pillow)?
How to Overhaul a Transformer Conservator (Oil Pillow)?
Overhaul Items for Transformer Conservator:1. Ordinary-Type Conservator Remove the end covers on both sides of the conservator, clean rust and oil deposits from inner and outer surfaces, then apply insulating varnish to the inner wall and paint to the outer wall; Clean components such as the dirt collector, oil level gauge, and oil plug; Check that the connecting pipe between the explosion-proof device and the conservator is unobstructed; Replace all sealing gaskets to ensure good sealing with n
Felix Spark
11/04/2025
Why is it difficult to increase the voltage level?
Why is it difficult to increase the voltage level?
The solid-state transformer (SST), also known as a power electronic transformer (PET), uses voltage level as a key indicator of its technological maturity and application scenarios. Currently, SSTs have reached voltage levels of 10 kV and 35 kV on the medium-voltage distribution side, while on the high-voltage transmission side, they remain in the stage of laboratory research and prototype validation. The table below clearly illustrates the current status of voltage levels across different appli
Echo
11/03/2025
Related Products
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.