What are the pros and cons of connecting two AC generators in parallel?

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

Advantages

  • Improve the reliability of power supply systems: Multiple AC generators are connected in parallel to form a power grid, ensuring stable voltage and frequency of power supply, and can withstand the impact of large changes in load.

  • Easy Maintenance: Multiple units can be used in parallel, allowing for centralized scheduling and distribution of active and reactive loads, making maintenance and repairs more convenient and timely.

  • Economics: Depending on the load size, appropriate numbers of small-capacity units can be invested to reduce fuel and oil waste caused by large-capacity units running at low load.

  • Scalability: By installing only the power generation and parallel equipment needed at present, diesel generators can be added later when there is a need to expand the capacity of the power grid. This allows for easy paralleling of expansion units, making the initial investment more economical.

Improving Power Supply Quality: Parallel operation of AC generators can enhance power supply quality because if one generator trips due to a fault, the other parallel generators in the system will share the load, thereby preventing power interruptions caused by the tripping of a single generator.

Disadvantages

  • Increased Complexity: Parallel operation requires ensuring that voltage, frequency, and phase are identical, which adds complexity to the system.

  • Synchronization Difficulty: Achieving synchronization requires precise control and synchronized devices such as sync lights, relays, or synchronizers.

  • High Maintenance Requirements: While parallel operation provides better maintenance convenience, it also demands higher maintenance skills and more complex maintenance procedures.

  • Increased Initial Investment : Although parallel operation may be more economical in the long run, the initial investment, including the cost of parallel equipment and synchronizing control systems, may be higher.

In summary, the parallel operation of two AC generators can provide a more reliable power supply, facilitate maintenance and expansion, and in some cases be more economical. However, it also brings about increased system complexity, greater difficulty in synchronization, and the requirement for higher maintenance skills. Therefore, when deciding whether to adopt parallel operation, it is necessary to consider the specific application requirements and budget constraints comprehensively.

Give a tip and encourage the author!
Recommended
In-Depth Analysis of Fault Protection Mechanisms for Generator Circuit Breakers
In-Depth Analysis of Fault Protection Mechanisms for Generator Circuit Breakers
1.Introduction1.1 Basic Function and Background of GCBThe Generator Circuit Breaker (GCB), as the critical node connecting the generator to the step-up transformer, is responsible for interrupting current under both normal and fault conditions. Unlike conventional substation circuit breakers, the GCB directly withstands the massive short-circuit current from the generator, with rated short-circuit breaking currents reaching hundreds of kiloamperes. In large generating units, the reliable operati
Felix Spark
11/27/2025
Research and Practice of Intelligent Monitoring System for Generator Circuit Breaker
Research and Practice of Intelligent Monitoring System for Generator Circuit Breaker
The generator circuit breaker is a critical component in power systems, and its reliability directly affects the stable operation of the entire power system. Through research and practical application of intelligent monitoring systems, the real-time operational status of circuit breakers can be monitored, enabling early detection of potential faults and risks, thereby enhancing the overall reliability of the power system.Traditional circuit breaker maintenance primarily relies on periodic inspec
Edwiin
11/27/2025
Why Install GCB at Generator Outlets? 6 Core Benefits for Power Plant Operations
Why Install GCB at Generator Outlets? 6 Core Benefits for Power Plant Operations
1.Protects the GeneratorWhen asymmetric short circuits occur at the generator outlet or the unit bears unbalanced loads, the GCB can quickly isolate the fault to prevent generator damage. During unbalanced load operation, or internal/external asymmetric short circuits, twice the power frequency eddy current is induced on the rotor surface, causing additional heating in the rotor. Meanwhile, the alternating electromagnetic torque at twice the power frequency induces double-frequency vibration in
Echo
11/27/2025
Silent Diesel Generator Installation Guide: Key Steps & Critical Details for Efficiency
Silent Diesel Generator Installation Guide: Key Steps & Critical Details for Efficiency
In industrial production, emergency rescue, commercial buildings, and other scenarios, silent-canopy diesel generator sets serve as the “core backup” for stable power supply. The quality of on-site installation directly determines the unit’s operational efficiency, noise control performance, and service life; even minor oversights may lead to potential faults. Today, based on practical experience, we outline the complete standardized procedures and critical details for on-site installation of si
James
11/27/2025
Related Products
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.