Calibration Technology Challenges and Countermeasures for DC Electronic Current Transformers

Echo
Echo
Field: Transformer Analysis
China

In modern power systems, DC electronic current transformers play a crucial role. They are not only used for high-precision current measurement but also serve as key tools for grid optimization, fault detection, and energy management. With the rapid development of high-voltage direct current (HVDC) transmission technology and its widespread deployment globally, the performance requirements for DC current transformers have become increasingly stringent, especially in terms of measurement accuracy and system compatibility. Therefore, the calibration technology of DC electronic current transformers has become the key to ensuring the safe, stable, and efficient operation of power systems.

1 Analysis of Calibration Technology for DC Electronic Current Transformers
1.1 Basic Principles of Calibration

The calibration of DC electronic current transformers is based on the principle of the magnetic-modulation DC current comparator and optical fiber digital synchronization technology. Among them, the magnetic-modulation DC current comparator uses magnetic-modulation technology to measure the magnitude of DC current. This technology relies on the influence of the magnetic field generated by the current on the magnetic properties of the iron core. In practical applications, when the current flows through the main conductor, it magnetizes the surrounding iron core. The magnetized iron core affects the current in a secondary coil through its changes, and this influence can be used as the basis for measuring the magnitude of the current in the main conductor.

1.2 Composition of the Calibration System

The calibration system for DC electronic current transformers is mainly composed of a DC current source, the connection and synchronous configuration of the standard device and the device under test, and a high-precision data acquisition unit. The design and function of each part play a decisive role in the accuracy and reliability of the calibration process.

  • The DC current source is responsible for providing a stable and adjustable current for calibration. Its design needs to meet the requirements of high stability and low ripple output to simulate the performance of the current transformer under different current conditions. To achieve this goal, the current source usually adopts precision power electronic components and a closed-loop feedback control system to adjust the output in real time and maintain current stability. Even when the load changes or the power supply fluctuates, it can ensure the accuracy of the output current.

  • When the DC current source provides the basic current, the correct connection and synchronization of the standard device and the device under test are key links to ensure the accuracy of the calibration results. The standard device is generally a high-precision instrument certified by the state, providing a current value with a known accuracy as a reference; the device under test is the current transformer to be tested. During the calibration process, the standard device and the device under test must be operated in strict synchronization to ensure that all measurement data are obtained under the same operating conditions.

1.3 Calibration Methods

In the calibration process of DC electronic current transformers, the selection of calibration methods plays a decisive role in the accuracy and reliability of the measurement results. On-site calibration and laboratory calibration each have unique advantages and disadvantages. The high-accuracy digital direct measurement method provides an efficient calibration means. The calibration methods for analog and digital outputs are specifically adjusted for current transformers of different output types to adapt to various application scenarios.

(1) Comparison between On-site Calibration and Laboratory Calibration

There are significant differences between the two in terms of methods and environments:

  • On-site Calibration: It is carried out directly at the installation location of the current transformer and can reflect the influence of environmental factors such as temperature, humidity, and electromagnetic interference. It is suitable for large equipment whose installation location is difficult to move or whose performance needs to be verified. However, if there are a large number of unfavorable factors on-site and the environmental variables cannot be effectively controlled, the calibration accuracy is likely to be affected.

  • Laboratory Calibration: The environment can be effectively controlled, and the test conditions can be precisely regulated, which improves the repeatability and accuracy of calibration. However, the laboratory environment cannot completely simulate the on-site working scenario, and it is difficult to comprehensively analyze the impact of the on-site environment on the equipment performance.

(2) High-accuracy Digital Direct Measurement Method

With the help of high-precision digital measurement equipment, the output of the current transformer is directly read and compared with the known standard value, so that the calibration result can be obtained quickly and efficiently, and the error in intermediate links is reduced.

(3) Calibration Methods for Analog and Digital Outputs

The advantage of this method lies in fully considering the output characteristics of different types of current transformers:

  • Analog Output Method: A high-precision current measuring instrument is used to read the output value, and then it is compared with the standard value for calibration to ensure the accuracy of analog signal conversion and measurement.

  • Digital Output Method: In the calibration process, analysis software and synchronization technology are combined for data transmission and processing to ensure that the calibration accuracy meets the requirements, which is suitable for the calibration needs of current transformers with digital output.

2 Challenges and Countermeasures in Applying DC Electronic Current Transformer Calibration Technology
2.1 On - site Anti - interference

When applying DC electronic current transformer calibration on - site, severe electromagnetic interference arises. It stems from the high - voltage grid’s electromagnetic environment, including radiation from cables/equipment and system - generated noise. Such interference impacts measurement accuracy, causing calibration data deviations in HVDC systems and even damaging components. It brings both instant errors and long - term stability/reliability issues.

To tackle this, optimizing the magnetic shielding structure is key. The principle is using high - permeability materials to build a shielding layer around sensitive parts, blocking external magnetic fields. When designing, assess the actual environment (interference type, intensity, frequency) as these affect shielding effectiveness. A laminated structure with multi - layer, different - permeability materials works better. For example, the outer layer uses high - permeability materials to absorb most magnetic fields, and the inner layer uses high - resistivity materials to block residual fields. Optimized magnetic shielding design data is in Table 1.

2.2 Digital Synchronization Precision

In DC electronic current transformer calibration, synchronization precision is critical. Calibration often needs synchronizing multiple devices/data sources in scattered locations. Data precision/reliability depends on time synchronization; small deviations cause inaccuracies, affecting power system efficiency/safety. Selecting/optimizing synchronization tech and comparing optical fiber & GPS synchronization are vital.

In selecting/optimizing, the challenge is controlling complex power environments and wide geographical distributions for accurate synchronization. In strong - interference environments, traditional methods fail. Solutions include introducing IEEE1588 Precision Time Protocol and using precise time - stamping/modern communication for synchronization.

Optical fiber synchronization, with high speed and anti - interference, suits high - precision scenarios (e.g., data centers). It’s unaffected by electromagnetic interference, ensuring signal purity, but has high deployment costs. GPS synchronization is cost - effective, covers wide areas, and fits scattered networks. It uses satellite signals for time stamps but is less stable under severe interference. Synchronization precision comparison under different interferences is in Figure 1.

To address these challenges, select appropriate synchronization tech based on application environment and calibration needs. Prioritize fiber optic sync for low - EMI, high - precision scenarios. For geographically dispersed power networks, consider GPS sync and optimize receiver placement to reduce signal interference. Combining both to add redundancy also boosts sync precision and system reliability.

3 Conclusion

In conclusion, by conducting in - depth research on the calibration technology of DC electronic current transformers and their applications, it is not only of great significance for improving the performance and reliability of current transformers, but also a key factor in driving technological innovation and sustainable development of power systems. In the future, while continuing to optimize the calibration technology, attention should also be paid to the performance of these technologies in practical applications to ensure that they can meet the high - standard requirements of modern power grids.

Give a tip and encourage the author!
Recommended
3D Wound-Core Transformer: Future of Power Distribution
3D Wound-Core Transformer: Future of Power Distribution
Technical Requirements and Development Trends for Distribution Transformers Low losses, especially low no-load losses; highlighting energy-saving performance. Low noise, particularly during no-load operation, to meet environmental protection standards. Fully sealed designto prevent transformer oil from contacting external air, enabling maintenance-free operation. Integrated protection devices within the tank, achieving miniaturization; reducing transformer size for easier on-site installation. C
Echo
10/20/2025
Reduce Downtime with Digital MV Circuit Breakers
Reduce Downtime with Digital MV Circuit Breakers
Reduce Downtime with Digitized Medium-Voltage Switchgear and Circuit Breakers"Downtime" — it’s a word no facility manager wants to hear, especially when it’s unplanned. Now, thanks to next-generation medium-voltage (MV) circuit breakers and switchgear, you can leverage digital solutions to maximize uptime and system reliability.Modern MV switchgear and circuit breakers are equipped with embedded digital sensors that enable product-level equipment monitoring, providing real-time insights into the
Echo
10/18/2025
One Article to Understand the Contact Separation Stages of a Vacuum Circuit Breaker
One Article to Understand the Contact Separation Stages of a Vacuum Circuit Breaker
Vacuum Circuit Breaker Contact Separation Stages: Arc Initiation, Arc Extinction, and OscillationStage 1: Initial Opening (Arc Initiation Phase, 0–3 mm)Modern theory confirms that the initial contact separation phase (0–3 mm) is critical to the interrupting performance of vacuum circuit breakers. At the beginning of contact separation, the arc current always transitions from a constricted mode to a diffused mode—the faster this transition, the better the interruption performance.Three measures c
Echo
10/16/2025
Advantages & Applications of Low-Voltage Vacuum Circuit Breakers
Advantages & Applications of Low-Voltage Vacuum Circuit Breakers
Low-Voltage Vacuum Circuit Breakers: Advantages, Application, and Technical ChallengesDue to their lower voltage rating, low-voltage vacuum circuit breakers have a smaller contact gap compared to medium-voltage types. Under such small gaps, transverse magnetic field (TMF) technology is superior to axial magnetic field (AMF) for interrupting high short-circuit currents. When interrupting large currents, the vacuum arc tends to concentrate into a constricted arc mode, where localized erosion zones
Echo
10/16/2025
Related Products
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.