Protection measures of three-phase transformer

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

Protection measures for use of three-phase transformers


Three-phase transformer may encounter various faults and abnormal working conditions during use, in order to ensure its safe and stable operation, a series of protective measures are usually taken. The following are several common protection measures for three-phase transformers according to the search results:


Gas protection


Gas protection is a protective measure used to reflect the internal failure of the transformer tank and the reduction of the oil level. When the fault in the tank produces slight gas or the oil level drops, the gas protection should be activated at the signal; When a large amount of gas is generated, the circuit breaker on each side of the transformer should be disconnected.


Longitudinal differential protection or current velocity break protection


This protection measure is used to reflect the short-circuit between the transformer winding and the lead line, and the single-phase grounding short-circuit between the neutral point direct grounding system winding and the lead line. It can quickly detect the fault and activate the protection mechanism, cut off the power and avoid the expansion of the fault.


Overcurrent protection


Overcurrent protection is used to reflect the external phase short circuit of the transformer, and as a backup protection for gas protection and differential protection (or current current break protection). This protection can be used as the last line of defense when the gas protection and differential protection fail, cutting off the power supply and protecting the transformer from damage.


Zero sequence current protection


Zero sequence current protection is used to protect the external single-phase grounding short circuit of the system with high grounding current. It detects the presence of zero sequence current and initiates protective action to avoid transformer damage due to ground failure.


Overload protection


Overload protection is used to reflect the symmetric overload of the transformer. This protection only acts on the signal and does not immediately cut off the power supply, but warns the staff that the transformer is overloaded and needs to be adjusted.


Overexcitation protection


Overexcitation protection is used to prevent transformer damage due to overexcitation. When the overexcitation of the transformer exceeds the allowable limit, the overexcitation protection will be activated, sending a signal or acting on the trip, limiting the degree of overexcitation.


Differential protection


Differential protection is an important protection measure, which can reflect the fault of transformer outlet line, bushing and internal short circuit. This kind of protection can be operated instantaneously on each side of the transformer circuit breaker, which is of great significance for the protection of transformer equipment.


Neutral point direct grounding protection


For the transformer directly grounded at the neutral point, when the single phase grounding fault occurs, it will produce a large short circuit current. The ground protection device determines whether the ground fault occurs by detecting the zero sequence current, and acts to remove the fault part in time.


Neutral point is not grounded or protected by arc suppression coil


For the transformer with ungrounded neutral or grounded by arc suppression coil, when the single-phase grounding fault occurs, the grounding current is small, and the zero-sequence voltage protection or insulation monitoring device is usually used to detect the grounding fault.


Temperature protection


The transformer will generate heat during operation, and when the temperature is too high, the insulation performance and service life of the transformer will be affected. The purpose of temperature protection is to monitor the temperature change of the transformer, and when the temperature exceeds the set value, send an alarm signal or act on the trip to prevent the transformer from overheating and damage.


Give a tip and encourage the author!
Recommended
What Is a Magnetic Levitation Transformer? Uses & Future
What Is a Magnetic Levitation Transformer? Uses & Future
In today’s rapidly advancing technological era, the efficient transmission and conversion of electric power have become continuous goals pursued across various industries. Magnetic levitation transformers, as an emerging type of electrical equipment, are gradually demonstrating their unique advantages and broad application potential. This article will thoroughly explore the application fields of magnetic levitation transformers, analyze their technical characteristics and future development tren
Baker
12/09/2025
How Often Should Transformers Be Overhauled?
How Often Should Transformers Be Overhauled?
1. Transformer Major Overhaul Cycle The main transformer shall undergo a core-lifting inspection before being put into service, and thereafter a core-lifting overhaul shall be performed every 5 to 10 years. Core-lifting overhaul shall also be carried out if a fault occurs during operation or if issues are identified during preventive tests. Distribution transformers operating continuously under normal load conditions may be overhauled once every 10 years. For on-load tap-changing transformers, t
Felix Spark
12/09/2025
Low-Voltage Distribution Lines and Power Distribution Requirements for Construction Sites
Low-Voltage Distribution Lines and Power Distribution Requirements for Construction Sites
Low-voltage distribution lines refer to the circuits that, through a distribution transformer, step down the high voltage of 10 kV to the 380/220 V level—i.e., the low-voltage lines running from the substation to the end-use equipment.Low-voltage distribution lines should be considered during the design phase of substation wiring configurations. In factories, for workshops with relatively high power demand, dedicated workshop substations are often installed, where transformers supply power direc
James
12/09/2025
Adjustment and Precautions for H61 Oil Power 26kV Electric Transformer Tap Changers
Adjustment and Precautions for H61 Oil Power 26kV Electric Transformer Tap Changers
Preparatory Work Before Adjusting the Tap Changer of H61 Oil Power 26kV Electric Transformer Apply for and issue a work permit; carefully fill out the operation ticket; conduct a simulation board operation test to ensure the operation is error-free; confirm the personnel who will carry out and supervise the operation; if load reduction is required, notify affected users in advance. Before construction, power must be disconnected to take the transformer out of service, and voltage testing must be
James
12/08/2025
Related Products
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.