Two kinds of (6~20)/0.4kV transformer high voltage side switch configuration diagram

Master Electrician
Master Electrician
Field: Basic Electrical
0
China

Two kinds of (6~20)/0.4kV transformer high voltage side switch configuration diagram

屏幕截图 2024-09-26 100256.jpg

Give a tip and encourage the author!
Recommended
 Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes of Fire and Explosion in Oil Circuit Breakers When the oil level in an oil circuit breaker is too low, the oil layer covering the contacts becomes too thin. Under the effect of the electric arc, the oil decomposes and releases flammable gases. These gases accumulate in the space beneath the top cover, mixing with air to form an explosive mixture, which can ignite or explode under high temperature. If the oil level inside the tank is too high, the released gases have limited space to expan
Felix Spark
11/06/2025
LTB vs DTB vs GIS: HV Circuit Breaker Comparison
LTB vs DTB vs GIS: HV Circuit Breaker Comparison
The basic meaning of a high-voltage circuit breaker is, simply put, that under normal conditions, it is used to open (interrupt, trip) and close (make, reclose) circuits, feeders, or specific loads—such as those connected to transformers or capacitor banks. When a fault occurs in the power system, protective relays activate the circuit breaker to interrupt either load current or short-circuit current, thereby ensuring the safe operation of the power system.A high-voltage circuit breaker is a typ
James
11/06/2025
What are the technical measures for loss reduction and energy saving in distribution systems?
What are the technical measures for loss reduction and energy saving in distribution systems?
1.Reasonable Use of TransformersTransformers should be selected with flexible winding configurations according to the power consumption characteristics of industrial enterprises, and load adjustments should be made promptly based on each transformer’s load rate to ensure operation at optimal loading conditions. Three-phase loads on transformers should be kept as balanced as possible; unbalanced operation not only reduces output capacity but also increases losses. Energy-efficient transformers sh
Echo
11/06/2025
What are the advantages of using a common grounding system in power distribution, and what precautions should be taken?
What are the advantages of using a common grounding system in power distribution, and what precautions should be taken?
What Is Common Grounding?Common grounding refers to the practice where a system’s functional (working) grounding, equipment protective grounding, and lightning protection grounding share a single grounding electrode system. Alternatively, it may mean that grounding conductors from multiple electrical devices are connected together and linked to one or more common grounding electrodes.1. Advantages of Common Grounding Simpler system with fewer grounding conductors, making maintenance and inspecti
Echo
11/05/2025