Sources and Causes of Low Power Factor

05/05/2025

Causes and Sources of Poor Power Factor
In an electrical power system, the power factor is defined as the ratio of real power (measured in kilowatts, kW) to apparent power (measured in kilovolt - amperes, kVA). A low power factor indicates that the electrical load is not efficiently utilizing the available electrical power. This inefficiency can lead to several consequences, such as elevated electricity costs for consumers and decreased overall system efficiency. In this article, we will delve into the primary sources and causes of a low power factor within an electrical system.
The most significant contributor to a low power factor is the presence of inductive loads. In a purely inductive circuit, the current lags behind the voltage by 90 degrees. This substantial phase - angle difference results in a power factor of zero, meaning that no real power is being effectively consumed by the load; instead, energy is merely being stored and released in the magnetic field of the inductor without performing useful work. In circuits that contain both capacitive and inductive elements, the power factor is non - zero. However, except in resonance or tuned circuits where the inductive reactance XL is equal to the capacitive reactance XC, making the circuit behave purely resistively, the phase - angle difference θ between the current and voltage persists. This phase difference, caused by the interplay between capacitance and inductance, directly impacts the magnitude of the power factor, often leading to suboptimal power - utilization conditions.
Causes and Sources of Low Power Factor
Causes of Low Power Factor
Several factors contribute to a low power factor in electrical systems, as detailed below:
Inductive Loads
Inductive loads, including electric motors and transformers, are among the primary culprits. These loads consume reactive power from the electrical system, resulting in a lagging power factor. In inductive circuits, the current lags behind the voltage, creating a phase difference that increases the reactive power component. The power factor of an inductive load varies significantly depending on its operating state:
  • Full Load: Typically, the power factor (Pf) ranges from 0.8 to 0.9.
  • Small Load: It drops to a range of 0.2 to 0.3.
  • No Load: The power factor can approach zero. In a pure inductor load, the power factor is exactly zero, indicating that no real work is being done, and energy is merely being stored and released in the magnetic field.

Capacitive Loads

Capacitive loads, such as capacitors, have the potential to improve power factor by generating reactive power. However, if the capacitance is excessive, it can lead to overcompensation, resulting in a leading power factor. Similar to pure inductive loads, a pure capacitive load also has a power factor of zero, as the current leads the voltage by 90 degrees, and there is no net real - power transfer.
Harmonics
Harmonics are non - linear distortions of the electrical waveform that commonly occur in systems with electronic loads, such as computers, servers, and other digital devices. These distortions cause an increase in reactive power, which in turn reduces the overall power factor. The presence of harmonics disrupts the sinusoidal nature of the current and voltage, leading to inefficiencies in power utilization.
Magnetizing Current
The load on a power system is not constant. During periods of low load, the supply voltage often increases. This increase in voltage leads to a rise in the magnetizing current of inductive equipment, such as transformers and motors. As a result, the power factor decreases, since more reactive power is being consumed relative to real power.
Undersized Wiring
Undersized wiring, particularly in motor windings, can cause significant voltage drops. These voltage drops increase the reactive power in the system, thereby lowering the power factor. Inadequate wire size restricts the flow of electrical current, causing resistive losses and increased impedance, which impacts the power - factor performance.
Long Distribution Lines
Long electrical distribution lines are another factor contributing to low power factor. As electricity travels over extended distances, resistance and reactance in the lines cause voltage drops. These voltage drops lead to an increase in reactive power, reducing the overall power factor of the system. The longer the line, the more pronounced these effects become.
Unbalanced Loads
Unbalanced loads, where the electrical load is unevenly distributed across the phases of a three - phase system, can cause an increase in the reactive power component. This uneven distribution leads to inefficiencies in power transfer, resulting in a lower power factor. Unbalanced loads can also cause additional stress on electrical equipment, potentially leading to premature failure.
Sources of Poor Power Factor
The following are the major sources of low power factor in electrical systems:
Electrical Equipment
  • Distribution Transformers: The power factor of a distribution transformer depends on its design, as well as the level of loading and unloading. In general, an unloaded transformer has a very low power factor due to its magnetizing current requirements.
  • Lighting Systems
    • Incandescent Lamps: These typically have a power factor of around 50%.
    • Mercury Vapor Lamps: Their power factor usually ranges from 40% to 60%.
  • Motors
    • Induction Motors: The power factor of induction motors can vary widely, from 30% under light loads to 90% at full load.
    • Synchronous Motors: When operating under - excited conditions, synchronous motors exhibit a very low power factor.
  • Specialized Equipment
    • Welding Transformers: These generally have a power factor of about 60%.
    • Industrial Heating Furnaces: Their operation often results in a relatively low power factor due to the nature of the electrical loads involved.
    • Solenoids and Chokes: These inductive components contribute to poor power - factor performance.
    • Arc Lamps: Similar to other electrical lighting sources, arc lamps can have a low power factor.

System - Level Issues

  • Under - Excited Synchronous Motors: When operating at load with insufficient excitation, synchronous motors consume excessive reactive power, leading to a low power factor.
  • Inadequate Wiring Practices: Not using the rated wire size in motor windings can cause power - factor problems, as discussed earlier.
  • Mechanical Issues in Motors: Damaged bearings in motors can cause mechanical stress, which in turn affects the electrical characteristics of the motor, potentially leading to a decrease in power factor.
Addressing low power factor is crucial, as it has several drawbacks, including increased energy losses, higher electricity bills, and reduced system capacity. To improve power factor, various solutions can be implemented. These include installing power - factor - correction equipment, such as capacitors, upgrading electrical equipment to minimize losses, and optimizing system design to reduce reactive - power consumption. A thorough understanding of the causes and sources of low power factor is essential for identifying areas of improvement and ensuring the efficient and cost - effective operation of electrical systems.

Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.

Difference Between Short Circuit & Overload
Difference Between Short Circuit & Overload
One of the main differences between a short circuit and an overload is that a short circuit occurs due to a fault between conductors (line-to-line) or between a conductor and earth (line-to-ground), whereas an overload refers to a situation where equipment draws more current than its rated capacity from the power supply.Other key differences between the two are explained in the comparison chart below.The term "overload" typically refers to a condition in a circuit or connected device. A circuit
08/28/2025
Difference Between Leading and Lagging Power Factor
Difference Between Leading and Lagging Power Factor
Leading and lagging power factors are two key concepts related to the power factor in AC electrical systems. The main difference lies in the phase relationship between current and voltage: in a leading power factor, the current leads the voltage, whereas in a lagging power factor, the current lags behind the voltage. This behavior depends on the nature of the load in the circuit.What is Power Factor?Power factor is a crucial, dimensionless parameter in AC electrical systems, applicable to both s
08/26/2025
Difference Between Electromagnet and Permanent Magnet
Difference Between Electromagnet and Permanent Magnet
Electromagnets vs. Permanent Magnets: Understanding the Key DifferencesElectromagnets and permanent magnets are the two primary types of materials that exhibit magnetic properties. While both generate magnetic fields, they differ fundamentally in how these fields are produced.An electromagnet generates a magnetic field only when an electric current flows through it. In contrast, a permanent magnet inherently produces its own persistent magnetic field once it has been magnetized, without requirin
08/26/2025
Interpretation of the “Five Mandatory Surveys” for On - site Investigation in the Operation and Maintenance Specialty
Interpretation of the “Five Mandatory Surveys” for On - site Investigation in the Operation and Maintenance Specialty
The power outage and work scopes must be clearly inspectedCollaborate with the site survey leader to confirm the equipment to be maintained and the work area involved. Consider requirements such as the use of special vehicles and large machinery, and safe distances from adjacent energized equipment. Verify on-site whether the proposed power outage scope is sufficient to meet the operational needs.On-site safety measures must be clearly inspectedCollaborate with the site survey leader to verify s
Vziman
08/14/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!